1. PC5400 Programming Section [801]
2. PC5936 Programming Section [802]
• PC5936 audio interface will allow you to connect to 16
Interior (PC5921) or exterior (PC5921EXT) Intercom
Station. These surface mounted stations contain a
speaker and a microphone. This module enables Page/
Answer, Do Not Disturb, Baby Monitor, Answer
Incoming Calls, Doorbell Function, and Background
Music features in your alarm. This module also has the
Listen-in feature for central station monitoring. The
central station can select the audio station, listen/talk,
extend on-line time and hang up. The Listen-In feature
can be enabled separately for telephone numbers 1/3
and 2.
All Talk/Listen and/or video sessions will be discon-
nected if the panel needs to communicate alarms to the
central station.
• Alternate Communicator Programming Section [803]
• PC5132 Programming Section [804]
• PC5100 Programming Section [805]
• PC5108L Programming Section [806]
NOTE:
All Talk/Listen and/or video sessions are discon-
nected when the panel communicates alarms to the
central station.
• T-Link Programming Section [851]
NOTE:
Option [5] in Section [382] must be enabled to
access this section.
The T-Link module can be used to communicate panel
events in SIA format over a Local Area Network (LAN). It
can also be used for downloading (this requires DLS-3 v1.3).
Telephone 1 & 3 Listen-In Enabled . . . . . . . Section [381], Option 5
Telephone 2 Listen-In Enabled . . . . . . . . . . Section [381], Option 6
Periodic Camera Test
When the
Periodic Camera Test
option is enabled, the
panel will test cameras connected to a PC5108L module
every 30 minutes. Only cameras with the Camera Test
option enabled will be tested. See your
PC5108L Installa-
tion Manual
for more information on camera tests.
If the
Local Mode
option is ON, the panel will send
events to the PC5108L module, Downlook will not be ini-
tiated if requested. If the Local Mode option is OFF, the
panel will send communicated events to the PC5108L
module. Downlook will initiate when requested. See your
PC5108L Installation Manual
for more information.See
Periodic Camera Test Section [017], Option [7] and Local
Mode Enabled/Disabled Section [381], Option [8]
5.11 Special Installer Instructions PWS Sect 11
[901] - Installer Walk Test Mode Enable / Disable
The
Installer Walk Test
can be used to test the alarm state
of each zone of the panel. The Walk Test cannot be used to
test zone type [24]. Before beginning the Walk Test, ensure
the following conditions are met:
1. The panel is disarmed
2. The Keypad Blanking option is disabled (section [016]: [3])
3. The Fire Bell is Continuous option is disabled (section
[014]: [8])
4. The Transmission Delay is disabled, if Transmission Delay is
not required (section [377])
NOTE:
Fire Troubles are not supported in Walk Test.
All outputs will activate for all partitions during the
Walk Test, regardless of programming.
To perform a Walk Test, do the following:
1. Enter Installer Programming
2. Enter Section [901]
When any zone is violated the panel will activate the Bell
Output for two seconds and log the event to the event
buffer. Check the event buffer to ensure that all zones and
FAP keys are functioning properly.
NOTE:
If there is no zone activity on the system for 15
minutes, the system will end the Walk Test and return
to the normal state.
To stop the test, you must do the following:
1. Enter Installer Programming
2. Enter Section [901]
Zones do not have to be restored to stop the test. After the
test is complete, check the event buffer to ensure that the
Audible/Silent 24-Hr. PGM alarms have been restored.
NOTE:
The Alarm Memory is cleared upon entering
Walk Test mode. When the Walk Test is complete, the
Alarm Memory will indicate the zones tested. The
Alarm Memory will be cleared the next time the panel
is armed.
NOTE:
While the Walk Test is in progress, all three
LEDs (Ready, Arm, Trouble) will flash at a rapid rate. At
the start of the Walk Test, a TS signal will be communi-
cated. When the test is stopped a TE (test end) is com-
municated.
[902] - Reset Module Supervision
All modules will automatically enroll within one minute
upon power up (except the PC5132 if there are no serial
numbers programmed). If modules are to be removed, this
section should be entered after the removal of the modules
so that it can clear any supervisory Troubles that may be
present. When this mode is entered, the system will re-eval-
uate the components of the system.
NOTE:
It may take up to a minute to enroll or delete a
module. Before entering Section [903] to view the
module field, this time should be taken into account.
If there is a module that is not properly communicating
with the system and this section is entered, the module
will be deleted from the system.
Once executed, all pending Supervisory Trouble Restorals
will not be logged or transmitted.
[903] - Module Supervision Field
When this mode is entered, the system will display all of
the modules presently enrolled on the system as indicated
below.
[904] - Module Placement Test
Module Selection
Upon entering Section [904], a 2-digit entry will be
required to select the zone number to be tested. Valid
entries are 01-32 for Zones 01-32 respectively. On an LCD
keypad, there are two ways to make a zone selection:
direct entry of 01-32, or by scrolling across to the descrip-
tion of the module (i.e. ’Zone 1’). If a module is selected
that is not enrolled, an error tone will sound.
[903] MODULE SUPERVISION FIELD
Indicator
Module
Lights 1-8
Keypads 1-8
Lights 9-14
Zone Expander Groups 1-6
Light 15
PC5100
Light 16
Zone Expander Group 7
Light 17
PC5132
Light 18
PC5208
Light 19
PC5204
Light 20
PC5400
Light 21
PC59XX
Light 22
Alternate Communicator
Light 23
Downlook Module
Light 24
Escort5580(TC)
Light 25
For Future Use
Light 26-29
PC520X1-4