Zone 102 Default (ON)

[6]

Zone 110 Default (ON)

[7]

Zone 103 Default (ON)

[7]

Zone 111 Default (ON)

[8]

Zone 104 Default (ON)

[8]

Zone 112 Default (ON)

[448] Session 1 Notification Zone 113-120

[449] Session 1 Notification Zone 121-128 Toggle

[1]

Zone 113 Default (ON)

[1]

Zone 121 Default (ON)

[2]

Zone 114 Default (ON)

[2]

Zone 122 Default (ON)

[3]

Zone 115 Default (ON)

[3]

Zone 123 Default (ON)

[4]

Zone 116 Default (ON)

[4]

Zone 124 Default (ON)

[5]

Zone 117 Default (ON)

[5]

Zone 125 Default (ON)

[6]

Zone 118 Default (ON)

[6]

Zone 126 Default (ON)

[7]

Zone 119 Default (ON)

[7]

Zone 127 Default (ON)

[8]

Zone 120 Default (ON)

[8]

Zone 128 Default (ON)

[450]-[476] Repeats [423]-[449] for Session 2

[477]-[503] Repeats [423]-[449] for Session 3

[504]-[530] Repeats [423]-[449] for Session 4

[691]-[694] Session 1 to 4 Notification Control

[1] - Alarm and Alarm Restore Notifications Off (ON)
[2] - Tamper and Tamper Restore Notifications Off (ON)
[3] - Disarming Notifications (ON)
[4] - Arming Notifications (ON)
[5] - Trouble and Trouble Restore Notifications (ON)
[6] - Test Transmission Notifications (ON)
[7] - Lighting Notifications (ON)
[8] - Temperature Notifications (ON)

[708] Event Report Retry Interval

Default (0A14285000000000) Valid range: 0000000000000000 - FFFFFFFFFFFFFFFF.

[709] Event Report Retry Timeout

Default (0000012C) Valid range: 00000000 - FFFFFFFF.

[710] Lifestyle Event Log Sync Timeout

Default (00015180) Valid range: 00000000 - FFFFFFFF.

[711] Integration Inactivity Timeout

Default (00000078) Valid range: 00000000 - FFFFFFFF.

[716] Lifestyle Reset Window

Default (0E10) Valid range: 0000 - FFFF.

[720] Local Debug TCP Port

Default (0000) Valid range: 0000 - FFFF.

[722] Lifestyle Zone 1-8 Toggle

[723] Lifestyle Zone 9-16 Toggle

[1]

Zone 1 Default (ON)

[1]

Zone 9 Default (ON)

[2]

Zone 2 Default (ON)

[2]

Zone 10 Default (ON)

[3]

Zone 3 Default (ON)

[3]

Zone 11 Default (ON)

[4]

Zone 4 Default (ON)

[4]

Zone 12 Default (ON)

[5]

Zone 5 Default (ON)

[5]

Zone 13 Default (ON)

[6]

Zone 6 Default (ON)

[6]

Zone 14 Default (ON)

[7]

Zone 7 Default (ON)

[7]

Zone 15 Default (ON)

[8]

Zone 8 Default (ON)

[8]

Zone 16 Default (ON)

33

Содержание LE2080

Страница 1: ...ath Alarm Communicator TL280 R E Internet Alarm Communicator Installation Manual v5 1 WARNING This manual contains information on limitations regarding product use and function and information on the limitations as to the liability of the manufacturer The entire manual should be carefully read PLEASE NOTE THAT NOT ALL MODELS AND FEATURES LISTED ARE AVAILABLE IN ALL MARKETS ...

Страница 2: ...ramming 13 Keypad Data Display 13 Entering HEX values at keypad 13 Entering ASCII Characters at keypad 13 HS2016 2032 2064 2128 Initial Programming 13 Activating the Communicator with C24 Communications 13 SMS Command and Control 13 SMS Commands 14 Communicator Status LEDs 14 Yellow Trouble LED 14 Panel Supervision Trouble 2 Flashes 14 SIM Lock Trouble 4 Flashes 15 Cellular Trouble 5 Flashes 15 Et...

Страница 3: ...ion Read Only 38 System Reset Defaults 42 Ethernet Cellular Programming Worksheets 43 System Options 43 Programming Options 43 System Test Options 44 Ethernet Receiver 1 Options 44 Ethernet Receiver 2 Options 44 Ethernet Options 44 Cellular Receiver 1 Options 44 Cellular Receiver 2 Options 45 Cellular Options 45 Command and Control Options 45 External Event Label Programming 50 Receiver Diagnostic...

Страница 4: ...ct the occupants or their belongings Motion Detectors Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions They cannot dis criminate between intruders and intended occupants Motion detectors do not provide volumetric area protection They have multiple beams of detection and motion can only be detected in unobstructed areas cover...

Страница 5: ...ls TL2803GRE EU TL2803GE EU 3G2080RE EU and 3G2080E EU are for Europe In ternational and cover the following bands 900 1800 MHz Models TL280LER TL280LE LE2080R LE2080 are for North America and support LTE bands B2 B4 B5 B12 and B13 and WCDMA bands B2 and B5 Band Transmit Band Tx Receive Band Rx LTE B2 1850 1910 MHz 1930 1990 MHz LTE B4 1710 1755 MHz 2110 2155 MHz LTE B5 824 849 MHz 869 894 MHz LTE...

Страница 6: ...ernet only l LE2080 R LTE 4 HSPA 3G only l TL280LE R Ethernet Internet LTE 4 HSPA 3G Features l 128 bit AES encryption via cellular and Ethernet Internet NIST validation cert number 2645 l Back up or primary cellular alarm communication l Automatically switches to 2G EDGE GPRS if HSPA 3G service is not available l Ethernet LAN WAN 10 100 BASE T TL2803G R E and TL280 R E only l Fully redundant Ethe...

Страница 7: ...e humidity non condensing Mechanical Specifications Board Dimensions mm 100 150 15 100 150 15 Weight grams with bracket 310 320 Table 2 Compatible Receivers and Panels Communicator Receiver Panel Description 3G2080 R E LE2080 R TL2803G R E TL280LE R TL280 R E Receiver l Sur Gard System I IP Receiver version 1 13 l Sur Gard System II Receiver version 2 10 l Sur Gard SG DRL3 IP version 2 30 for Sur ...

Страница 8: ...an required for proper termination l Do NOT kink knot cable l Do NOT crush cable with cable ties l Do NOT untwist CAT5 pairs more than in 1 2cm l Do NOT splice cable l Do NOT bend cable at right angles or make any other sharp bends NOTE CAT5 specification requires that any cable bend must have a minimum 2 in 5 cm bend radius Maximum length of CAT 5 cable is 328 ft 100 m Inserting and Removing the ...

Страница 9: ...ylon Washer with bushing thicker flat washer 7 Antenna Cable 8 Mounting Holes 9 Mounting Plate 10 Communicator Board 11 Stand Off 2 Install the Communicator into the panel a Attach one end of the PC LINK cable to the panel PCLINK_2 header on the panel red wire goes on the right hand pin of the panel PCLINK_2 header see Figure 3 b Insert the assembled communicator into the panel NOTE Ensure that th...

Страница 10: ...ng over the circuit board Maintain at least 1in 25 4mm separation between circuit board and wiring A minimum of in 7mm separation must be maintained at all points between non power limited wiring and power limited wiring 3 To electrically connect the communicator to the panel perform the following steps See Figure 3 a Disconnect both AC power and battery connections from the panel and disconnect t...

Страница 11: ...A TL2803G R E standby l 90mA 3G2080 R E LE2080 R l 120mA TL2803G R E TL280LE R l 400mA alarm DSC Panel minimum power requirements l 16 5 VAC 40 VA transformer l 12 VDC 7Ah battery 5 Install the RS 232 connections R models only If using the communicator with a 3rd party device wire the connections as per the table below Table 3 RS 232 Connections 3rd Party Device Communicator TX RX Unused RX RX TX ...

Страница 12: ...e panel location to be acceptable For interpretation of receiver strength on LEDs refer to the table Radio Signal Strength on page 10 Cellular Signal Strength Display LCD Keypad only The cellular network signal strength can be checked on the keypad LCD screen by entering installer pro gramming section 850 The LCD will indicate the SIM card activation status followed by up to five bars of signal st...

Страница 13: ...es at the keypad press the key before entering the HEX value e g to enter C at the keypad press 3 Entering ASCII Characters at keypad 1 Press and use scroll buttons to display ASCII Entry on the LCD screen 2 Press to select ASCII entry mode 3 Use the scroll keys to display the desired character and press to save and exit ASCII 4 Repeat the steps above to enter another ASCII character HS2016 2032 2...

Страница 14: ...of flashes indicates the type of trouble See the table below for the coded flashes and the conditions which will activate the trouble status LED Table 5 Yellow Trouble Status LED of Flashes Trouble of Flashes Trouble 2 Panel Supervision Trouble 8 Receiver Supervision Trouble 4 Not Applicable 9 FTC Trouble 5 Cellular Trouble 10 C24 Communications Configuration Failure 6 Ethernet Trouble 12 Module C...

Страница 15: ...This trouble is also indicated if the cellular receiver APNs have not been programmed in sections 205 and 215 Receiver Supervision Trouble 8 Flashes This trouble is indicated when receiver supervision is enabled and communication between the com municator module and the receiver fails Trouble is indicated if Ethernet 1 and or cellular 1 is supervised and does not receive a heartbeat from the recei...

Страница 16: ...LEDs Red and Green TL2803G R E TL280LE R only l Ethernet Activity Red LED will blink quickly once for transmit or twice for receive l Cellular Activity Green LED 2 will blink quickly once for transmit or twice for receive Communicator Troubleshooting NOTE For additional details l Refer to section 983 for troubleshooting the firmware updates l Refer to section 984 to view the trouble status l Refer...

Страница 17: ...ists replace the Ethernet cable and RJ45 connector Yellow LED 7 Flashes 07 Receiver Not Available l Ensure that the Ethernet path has Internet connectivity l If using a static IP address confirm that the gateway and subnet mask are entered correctly l If the network has a firewall ensure the network has the programmed outgoing ports open default UDP port 3060 and port 3065 l Ensure that all the re...

Страница 18: ...twork Format is 4 fields each field is a 3 digit decimal number Valid range 000 255 If an IP address is programmed in this section the unit will operate with static IP DHCP disabled Sections 002 and 003 must also be programmed when using static IP addresses NOTE Default for this section is Dynamic Host Configuration Protocol DHCP enabled When enabled the DHCP server will set values for IP address ...

Страница 19: ... is the primary path Ethernet channel is the secondary path if it exists OFF Ethernet channel is the primary path in a dual communicator Cellular channel is the secondary path 5 Redundant Communications Default OFF ON Events will be communicated to Ethernet receiver 1 and cellular receiver 1 at the same time Events will be communicated to Ethernet receiver 2 and cellular receiver 2 at the same tim...

Страница 20: ... DHCP is used the DHCP server will configure the address If an address is programmed and DHCP is used the programmed address will be used instead of the DHCP address 008 DNS Server IP 2 Default 000 000 000 000 Enter the IP address for DNS server 2 Format is 4 fields each field is a 3 digit decimal Valid range 000 255 NOTE If no value is programmed and DHCP is used the DHCP server will assign this ...

Страница 21: ...rewall and must be assigned a particular port number as determined by the network administrator In most cases changing the default value or configuring the firewall with this port is not required Valid range 0000 FFFF NOTE If section 006 toggle option 7 is ON DLS will use the primary path for session If section 006 toggle option 7 is OFF DLS will use the Ethernet path if available 015 DLS Call Up ...

Страница 22: ...ime 5D 11 VUT Vanuatu Time 5F 11 5 NFT Norfolk Island Time 61 12 NZST New Zealand Standard Time 64 12 75 CHAST Chatham Island Standard Time 65 13 TOT Tonga Time 69 14 LINT Line Island Time 70 FF N A N A N A 021 Account Code Default FFFFFF The account code is included when transmitting any events generated by the communicator e g panel absent trouble It is recommended that the account code be the s...

Страница 23: ...th the control panel have resumed 025 Radio Activation Restore Default FF Program 00 to disable this event or FF to enable This event will occur in North American cellular com municators when the unit has been programmed by Connect 24 System Test Options Test Transmissions to Primary Receiver with Backup to Secondary Receiver Set Ethernet section 026 to FF 027 to 00 Set cellular section 028 to FF ...

Страница 24: ... for details on settings 028 Cellular 1 Test Transmission Default FF Program 00 to disable this event transmission or FF to enable See system test options previous page for details on settings 029 Cellular 2 Test Transmission Default 00 Program 00 to disable this event transmission or FF to enable See system test options previous page for details on settings NOTE The time interval in minutes betwe...

Страница 25: ... and still wants to receive alarms without buying extra hardware receiver or software NOTE When a valid IP address has been programmed Ethernet receiver 1 is enabled and will com municate events over the Ethernet channel Ethernet receiver 1 and cellular receiver 1 may be configured to communicate to the same central station receiver To configure the device to operate using this common receiver mod...

Страница 26: ...efault 0BF5 3061 This section is used to program the port number used by Ethernet receiver 2 Set the value of this port when the installation is located behind a firewall and must be assigned a particular port number as determined by the central station system administrator Valid range 0000 FFFF NOTE Do not program Ethernet receiver 1 and Ethernet receiver 2 port with the same value 115 Ethernet R...

Страница 27: ...ge 0000 FFFF NOTE Programming this section with 0000 will disable the receiver 205 Cellular Receiver 1 APN Default The Access Point Name APN determines the cellular network that the communicator will connect to This information is available from the network carrier Program this section as 32 ASCII characters NOTE When a SIM card with a custom APN is used the unit will not have access to the Intern...

Страница 28: ...ter the Cellular Login User Name with up to 32 ASCII characters 223 Cellular Login Password Default Some network carriers require login credentials when connecting to an APN Program the login Pass word in this Section Enter the Cellular Login Password with up to 32 ASCII characters 224 Cellular Test Transmission Time of Day Default 9999 Enter a 4 digit value using the 24 hour clock format HHMM to ...

Страница 29: ...ximum message length is 160 characters 6 Long SMS Message Handling Default OFF ON If longer than maximum message length it is split and sent as multiple SMS messages OFF If longer than maximum message length A single truncated SMS message is sent 7 Reserved 8 Reserved 307 SMS Delimiter Default Valid entries are 00 FF 308 Outgoing SMS Retry Attempts Default 19 Valid entries are 00 FF The default va...

Страница 30: ...No Flow Control 5 8 Reserved 422 Integration Identification Number Default MAC IMEI This section will display the unique 12 digit number assigned to this communicator for the identification when integrated with third party applications 423 Session 1 Integration Access Code Default 12345678 Valid Range is 00000000 FFFFFFFF This section is a programmable 8 digit number used for initialization with t...

Страница 31: ...32 ASCII characters as provided by a third party device Refer to third party device manual for more information 432 Session 1 Integration Outgoing Port Default 0C04 3076 This section is used to program the outgoing port for integration via UDP 433 Session 1 Integration Incoming Port Default 0BFF 3071 This section is used to program incoming port for integration via TCP 434 Session 1 Notification Z...

Страница 32: ... Notification Zone 73 80 Toggle 1 Zone 65 Default ON 1 Zone 73 Default ON 2 Zone 66 Default ON 2 Zone 74 Default ON 3 Zone 67 Default ON 3 Zone 75 Default ON 4 Zone 68 Default ON 4 Zone 76 Default ON 5 Zone 69 Default ON 5 Zone 77 Default ON 6 Zone 70 Default ON 6 Zone 78 Default ON 7 Zone 71 Default ON 7 Zone 79 Default ON 8 Zone 72 Default ON 8 Zone 80 Default ON 444 Session 1 Notification Zone ...

Страница 33: ...ifications ON 4 Arming Notifications ON 5 Trouble and Trouble Restore Notifications ON 6 Test Transmission Notifications ON 7 Lighting Notifications ON 8 Temperature Notifications ON 708 Event Report Retry Interval Default 0A14285000000000 Valid range 0000000000000000 FFFFFFFFFFFFFFFF 709 Event Report Retry Timeout Default 0000012C Valid range 00000000 FFFFFFFF 710 Lifestyle Event Log Sync Timeout...

Страница 34: ...ifestyle Zone 57 64 Toggle 1 Zone 49 Default ON 1 Zone 57 Default ON 2 Zone 50 Default ON 2 Zone 58 Default ON 3 Zone 51 Default ON 3 Zone 59 Default ON 4 Zone 52 Default ON 4 Zone 60 Default ON 5 Zone 53 Default ON 5 Zone 61 Default ON 6 Zone 54 Default ON 6 Zone 62 Default ON 7 Zone 55 Default ON 7 Zone 63 Default ON 8 Zone 56 Default ON 8 Zone 64 Default ON 730 Lifestyle Zone 65 72 Toggle 731 L...

Страница 35: ...8 Zone 128 Default ON External Event Label Programming 738 883 Event Labels Default see Label Number in table There are 143 programmable event labels Each label is pre programmed with the default text shown in table Each label is up to 32 ASCII characters including spaces The language is specified in section 009 Table 13 External Event Labels Event Section Label Default Label Event Section Label D...

Страница 36: ... Label AC Power Trouble 781 Panel AC Power Restore Label AC Power Restore 782 Panel Auxiliary Power Trouble Auxiliary Power Trouble 783 Panel Auxiliary Power Restore Auxiliary Power Restore 784 Panel Battery Trouble Battery Trouble 785 Panel Battery Restore Battery Trouble Restore 786 Panel Bell Circuit Trouble Bell Circuit Trouble 787 Panel Bell Circuit Restore Bell Circuit Restore 788 Panel Tele...

Страница 37: ... Firmware Update Begin 836 Firmware Update Successful Firmware Update Successful 837 Firmware Update Fail Firmware Update Fail 838 Delinquency Delinquency 839 Keypad Lockout Keypad Lockout 840 Event Log 75 full Event Log Near Full 841 FTC Trouble Fail to communicate trouble 842 FTC Restore fail to communicate restore 843 Panel Absent Trouble Panel Communications Trouble 844 Panel Absent Trouble Re...

Страница 38: ...verify that the communications paths are available Diagnostic test trans mission failure will indicate as FTC trouble yellow LED 9 flashes If an FTC error occurs when testing all receivers select only one receiver and repeat test to isolate the receiver that is not communicating NOTE Sending a test transmission to a receiver that is not programmed generates an FTC trouble 961 Cellular Inactivity T...

Страница 39: ...ral variant mismatch 05 Firmware header wrong length Panel is Busy 20 System update pending panel is armed Disarm the panel to continue with system firmware update process 21 System update pending AC trouble Any AC trouble device module Resolve the AC trouble to continue with system firmware update process 22 System update pending low battery Any low battery trouble device module Resolve the low b...

Страница 40: ...tion code 984 Communicator Status The communicator status sections provide the installer with the status of the communicator s func tionality operational readiness and failures The communicator status is displayed as a 6 digit hexadecimal code The code ranges between 00000F and 2220CF though not all numbers in this range are assigned Each of the 6 digits represents a status or trouble indicator as...

Страница 41: ...2 initialized 7 Receiver 3 initialized 8 Receiver 4 initialized For example the radio initialization status code 12 45 indicates that radio has been powered up it has received SMS signal from C24 Communications the radio is attached to the network and receiver 1 has been initialized This code would update to 12 45678 when receivers 2 3 and 4 are initialized If the radio initialization status code ...

Страница 42: ...Industry Identifier 2 digits Mobile Country Code 2 or 3 digits Mobile Net work Code 2 3 digits Unique Number 10 12 digits and Checksum 1 digit Valid SIM numbers range is 18 21 numbers This number is printed on the SIM and the outside of the communicator car ton NOTE The checksum digit is omitted on 19 digit SIM card numbers 996 Cellular Telephone Number NOTE This section will display the cellular ...

Страница 43: ...nguage OPT Language 01 English 11 Swedish 21 Russian OPT Language OPT Language OPT Language 02 Spanish 12 Norwegian 22 Bulgarian 03 Portuguese 13 Danish 23 Latvian 04 French 14 Hebrew 24 Lithuanian 05 Italian 15 Greek 25 Ukrainian 06 Dutch 16 Turkish 26 Slovakian 07 Polish 17 Chinese 27 Serbian 08 Czech 18 Croatian 28 Estonian 09 Finnish 19 Hungarian 29 Slovenian 10 German 20 Romanian 30 99 Reserv...

Страница 44: ...F 103 Ethernet Receiver 1 Address Default 127 000 000 001 104 Ethernet Receiver 1 UDP Remote Port Default 0BF5 3061 Valid range 0000 FFFF 105 Ethernet Receiver 1 UDP Local Port Default 0BF4 3060 Valid range 0000 FFFF 106 Ethernet Receiver 1 Domain Name Default 32 ASCII characters ________________________________ Ethernet Receiver 2 Options 111 Ethernet Receiver 2 Account Code Default 0000000000 Va...

Страница 45: ...__________________________________ 224 Cellular Test Transmission Time of Day Default 9999 Valid range 00 23 hrs HH 00 59 min MM 225 Cellular Test Transmission Cycle Default 000000 Valid range 000000 999999 minutes 226 Network Trouble Delay Default 0F Valid entries from 00 to FF 227 Voice Call Timeout Default 00 Valid entries from 00 to FF 228 Voice Call Back Time Default 0A Valid entries from 00 ...

Страница 46: ... Integration Toggle Options 3 1 UDP Polling OFF 2 TCP Polling OFF 3 Real time Notification OFF 4 Notification Follows Pool OFF 5 Reserved 6 Reserved 7 Reserved 8 Reserved 427 Session 1 Interactive Polling Interval Default 000A Valid range 0000 FFFF seconds 428 Session 1 Integration Server IP Default 000 000 000 000 429 Session 1 Integration Notification Port Default 0C00 00372 Valid range 0000 FFF...

Страница 47: ...6 Default ON 441 Session 1 Notification Zone 57 64 Toggle 1 Zone 57 Default ON 2 Zone 58 Default ON 3 Zone 59 Default ON 4 Zone 60 Default ON 5 Zone 61 Default ON 6 Zone 62 Default ON 7 Zone 63 Default ON 8 Zone 64 Default ON 442 Session 1 Notification Zone 65 72 Toggle 1 Zone 65 Default ON 2 Zone 66 Default ON 3 Zone 67 Default ON 4 Zone 68 Default ON 5 Zone 69 Default ON 6 Zone 70 Default ON 7 Z...

Страница 48: ...ng Notifications Neo 1 4 only 8 Temperature Notifications Neo 1 4 only 692 Session 2 Notification Control 1 Alarm and Alarm Restore Notifications 2 Tamper and Tamper Restore Notifications 3 Disarming Notifications 4 Arming Notifications 5 Trouble and Trouble Restore Notifications 6 Test Transmission Notifications 7 Lighting Notifications Neo 1 4 only 8 Temperature Notifications Neo 1 4 only 693 Se...

Страница 49: ...N 8 Zone 32 Default ON 726 Lifestyle Zone 33 40 Toggle 1 Zone 33 Default ON 2 Zone 34 Default ON 3 Zone 35 Default ON 4 Zone 36 Default ON 5 Zone 37 Default ON 6 Zone 38 Default ON 7 Zone 39 Default ON 8 Zone 40 Default ON 727 Lifestyle Zone 41 48 Toggle 1 Zone 41 Default ON Default ON 2 Zone 42 Default ON 3 Zone 43 Default ON 4 Zone 44 Default ON 5 Zone 45 Default ON 6 Zone 46 Default ON 7 Zone 4...

Страница 50: ... Default ON 3 Zone 115 Default ON 4 Zone 116 Default ON 5 Zone 117 Default ON 6 Zone 118 Default ON 7 Zone 119 Default ON 8 Zone 120 Default ON 737 Lifestyle Zone 121 128 Toggle 1 Zone 121 Default ON 2 Zone 122 Default ON 3 Zone 123 Default ON 4 Zone 124 Default ON 5 Zone 125 Default ON 6 Zone 126 Default ON 7 Zone 127 Default ON 8 Zone 128 Default ON External Event Label Programming 738 Burglary ...

Страница 51: ...__________________________________ 765 CO Alarm Restore Default CO Alarm Restore _______________________________________ 766 Water Alarm Default Flood Alarm _______________________________________ 767 Water Alarm Restore Default Flood Alarm Restore _______________________________________ 768 Quick Bypass Alarm Default Quick Bypass Alarm _______________________________________ 769 Quick Bypass Alar...

Страница 52: ...___________________________________ 799 Alternate Communicator Restore Default Alternate Communicator Restore _______________________________________ 800 Module Trouble Default Module Trouble ______________________________________ 801 Module Trouble Restore Default Module Trouble Restore _______________________________________ 802 Wireless AML Device Trouble Default Device Trouble ________________...

Страница 53: ...r Lead Out Default Local Programming End _______________________________________ 835 Firmware Update Begin Default Firmware Update Begin _______________________________________ 836 Firmware Update Successful Default Firmware Update Successful _______________________________________ 837 Firmware Update Fail Default Firmware Update Fail _______________________________________ 838 Delinquency Default...

Страница 54: ...ault Successful _______________________________________ 871 Function Failure Default Unsuccessful _______________________________________ 872 Invalid Command Default Invalid Command _______________________________________ 873 System Stay Armed Default Stay Armed _______________________________________ 874 System Away Armed Default Away Armed _______________________________________ 875 System Night...

Страница 55: ...PA 3G 04 LTE 4G 05 LTE Advanced 4G 06 CDMA 2G 07 EVDO 3G 979 Cellular Network CSQ 980 Radio Reset Codes 981 Radio Type 982 Radio Firmware Version 983 Firmware Update Diagnostics Section 984 Communicator Status 985 Radio Initialization Status 986 System Toggle Options 4 1 Remote Shutdown Enable Default OFF 2 8 Reserved 987 Language Version 988 DNS 1 IP Address 989 DNS 2 IP Address 990 Boot Loader V...

Страница 56: ...laws of some jurisdictions limit or do not allow the disclaimer of consequential dam ages If the laws of such a jurisdiction apply to any claim by or against DSC the limitations and disclaimers contained here shall be to the greatest extent permitted by law Some states do not allow the exclu sion or limitation of incidental or consequential damages so that the above may not apply to you Disclaimer...

Страница 57: ...FTWARE PRODUCT with non DSC SOFTWARE or HARDWARE PRODUCTS LIMITATION OF LIABILITY WARRANTY REFLECTS ALLOCATION OF RISK IN ANY EVENT IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE AGREEMENT DSC S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADI...

Страница 58: ...S2128 064 032 016 The supported ATS configuration is cus tom category C 8 TL2803G R E EU 3G2080 R E EU TL280 R E has been tested for compliance in conjunction with the following applic able standards EN50136 1 2012 EN50136 2 2013 EN50131 10 2014 ATS configuration C For EN50131 1 2006 A1 2009 compliant installations the following pro gramming options shall be set as described Supervision Heartbeat ...

Страница 59: ...er Center SRC s receiver shall be programmed as maximum of 180 00B4 180 seconds For UL Residential Fire and Burglary applications the TL2803G R E 3G2080R TL280 R E LE2080 R TL280LE R can be used as the primary communication channel via either cellular or Ethernet or as a back up in conjunction with the DACT 30 day test transmission is required on each channel For UL Commercial Burglaryapplications...

Страница 60: ...essively enforce its intellectual property rights to the fullest extent of the law including pursuit of criminal prosecution wherever necessary All trademarks not owned by Tyco are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specifications are subject to change without notice Actual products may vary from photos Not al...

Отзывы: