Encryption
3G Alarm Communicator Installation Manual
8
E
NCRYPTION
The Communicator uses 128 Bit AES Encryption. Encryption can only be enabled from the monitoring station receiver. Each receiver
can independently have encryption enabled or disabled. When encryption is enabled, the central station will configure the device to
encrypt communications the next time the Communicator module performs a communication to that receiver.
NOTE:
Packets will start being encrypted only after the next event is sent to that receiver, or if the unit is restarted.
NOTE:
The Alarm Communicator is installed in the
SCW9055/SCW9057 prior to shipment by
Digital Security Controls (DSC). The Factory
Installation includes insertion of the SIM card.
The SCW9055/SCW9057 should not be
mounted in its final location without perform-
ing a Communicator Test to ensure adequate
HSPA/3G coverage for the
3G2075
and
TL2753G
Alarm Communicators.
I
NSTALLATION
L
OCATION
The Communicator shall be installed in an indoor loca-
tion only.
This HSPA/3G Ethernet Communicator shall be
installed by Service Persons only. (Service Person is
defined as a person having appropriate technical train-
ing and experience necessary to be aware of hazards to
which that person may be exposed in performing a task
and of measures to minimize the risks to that person or
other persons). The Communicator shall be installed
and used within an environment that provides the pollu-
tion degree max 2, over voltages category II, in non-
hazardous, indoor locations only. This manual shall be used with the Installation Manual of the alarm control panel which is connected
to the HSPA/3G Ethernet Communicator. All instructions specified within the control panel manual must be observed.
All the local rules imposed by local electrical codes shall be observed and respected during installation.
I
NSTALLING
CAT 5 C
ABLE
(TL2753G
ONLY
)
A Category 5 (CAT 5) ethernet cable must be run from a source with Ethernet/Internet
connectivity to the Communicator module, inside the Self Contained Wireless Control
Panel cabinet. The Communicator end of the cable must have an RJ-45 plug, which con-
nects to the Communicator’s RJ-45 jack. All requirements for installation of CAT5 ether-
net cable must be observed for correct operation of the Communicator, including, but not
limited to, the following:
•Do NOT strip off cable sheathing more than required for proper termination.
•Do NOT kink/knot cable.
•Do NOT crush cable with cable ties.
•Do NOT untwist CAT5 pairs more than 1.2cm (½”).
•Do NOT splice cable.
•Do NOT bend cable at right angles or make any other sharp bends.
NOTE:
CAT5 specification requires that any cable bend must have a minimum 5 cm (2
in.) bend radius. Maximum length of CAT 5 cable is 100m (328 ft.).
NOTE:
The Ethernet cable shall not be visible when the installation is complete unless
the install is a surface mount installation.
I
NSERTING
/R
EMOVING
THE
SIM C
ARD
1.Remove the front cover of the SCW9055/SCW9057 Control Panel
to access SIM card holder.
2.Remove power from the SCW9055/SCW9057 and disconnect the
backup battery connections.
3.On the SIM card holder push gently to slide the cover towards
OPEN as indicated by the arrow on SIM holder. This will unlatch
the SIM card holder on the side furthest from edge of the Communi-
cator. See Figure 1.
4.Lift up the SIM card holder from the side that is not hinged.
NOTE:
The SIM card can be damaged by bending or scratching contacts. Use caution when handling the SIM card.
5. Insert or remove the SIM card, noting the orientation of the notches on the SIM card and the SIM card holder.
C
OMMUNICATOR
C
ONFIGURATION
WITH
SCW9055/SCW9057
Figure 1: Communication Board Connection Points
RJ-45 Connector
DG0009635
Figure 2: RJ-45 Pinout
SIM Card Pinouts
DG0009396
Figure 3: SIM Card Pinouts