3G Alarm Communicator Installation Manual
Cellular Options
21
[222] Cellular Login User Name
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Program your login User Name in this Sec-
tion. Format is up to 32 ASCII characters.
NOTE:
This Section is not accessible via PC1616/PC1832/PC1864 keypad programming.
[223] Cellular Login Password
Default ( )
Some network carriers require you to provide login credentials when connecting to an APN. Program your login Password in this Sec-
tion.
Format is up to 32 ASCII characters.
[224] Cellular Test Transmission Time of Day
Default (9999)
Enter a 4 digit value using the 24-hour clock format (HHMM) to set the test transmission time of day. Valid range: 00-23 for the hours
(HH) and 00-59 for the minutes (MM).
NOTE:
To disable the test transmission time of day enter 9999 or FFFF in this Section.
The internal date and time will be automatically programmed by the primary receiver only.
[225] Cellular Test Transmission Cycle
Default (000000)
This value represents the interval in between test transmissions in minutes. Valid range: 000000 - 999999 minutes. Once the unit has
sent the initial periodic test transmission, all future test transmissions will be offset by the programmed number of minutes. See Sec-
tions [026] - [029].
NOTE:
Minimum value is 000005 minutes. Programming an interval that is less than 5 minutes will disable test transmission.
[226] Cellular Trouble Delay
Default (00)
This option is used to program the delay, in minutes, for reporting a Cellular Trouble Delay. Valid entries are 00 - FF. (e.g., for a 10 min-
ute Cellular Trouble Delay enter:
0A
). There is no reporting delay if value is programmed as 00.
[227] Voice Call Timeout
Default (00)
This option sets the Voice Call Timeout, in minutes. Programming a value of 00 will disable timeout. Valid range is 00 to FF.
[228] Voice Call Back Time
Default (0A)
This option sets the Voice call back time, in minutes. When the Communicator requests Call Back from the receiver, it will answer
incoming calls during the programmed timeout period. If an incoming call is received after the timeout from requesting call back, the
Communicator will answer the call and immediately hang up. Programming a value of 00 will disable timeout (accept all incoming
calls). Default value is 0A/10 seconds. Valid range is 00 to FF.
[229] Voice Call Back Number
Default (SIM Telephone Number)
This option sets the Voice Call Back Telephone Number for the receiver. This number is used for Two Way calling. Current SIM tele-
phone number can be viewed in Section [996]. Valid entry is 32 character ASCII.
Table 12: Cellular Test Transmission Interval
Test Transmission Interval
Daily
Weekly
Monthly
Programmed Minutes
001440
010080
043200