I N STA LLAT IO N M AN UAL

 

!Caution

Do not ignite the appliance before the gas, discharge and electric connections have been fully installed, first 
observe the procedure described in chapter 7.3.

5.6 Placing the chimney breast 

(if applicable)

For the benefit of a good heat discharge, operation of the appliance and general safety, there should be sufficient 
space around the appliance.
The chimney breast should be ventilated sufficiently by means of ventilation holes (incoming and outgoing). 
These are essential for safety and for the prevention of excess heat accumulation in the chimney breast.
 

!Caution

When an appliance is built in the floor, please take into account the minimum distances from a combustible 
floor. If applicable, additional information about this is provided from section 5.10 'Additional instructions'.

!Caution

Use non-combustible and heat-resistant materials for the chimney breast, including the top of the chimney 
breast and the material in the chimney breast, including the back wall and floor.

The appliance is not a support structure. Make sure the appliance does not have to bear the weight of the 
chimney breast for example.

The passage of the ventilation holes (outgoing), which are placed as high as possible, is stated in Appendix 2, 
Table 2.

If no control hatch is placed in the chimney breast, an air supply of at least 80 cm

2

 should be attached as low 

as possible. If there is, the control hatch will suffice as air supply.

!Caution

When placing the chimney breast, you should take the following into account (see Appendix 3, Fig. 2):

The location for the control hatch: this must be placed as low as possible.

The dimensions of the control hatch; see Placing the control hatch section 5.7.

The location of the ventilation holes (V) (outgoing).

Maintain a minimum 30 cm distance between the top of the ventilation hole (outgoing) and the ceiling of the 
house.

The measurements of the glass pane, so that it can be placed/removed after placing the chimney breast.

The protection of the gas control and the pipes against cement and plaster.

If possible, you should place decorative strips, frames, etc., after any required structural work has been 
completed. Prevent the use of painter's tape. If this is not possible: use a good quality painter's tape and 
remove it immediately after plastering or painting work.

 

!Tip

You should preferably apply the ventilation holes (outgoing) on both sides of the chimney breast. Use the DRU 
ventilation elements.
 
Check the following issues, before the chimney breast is fully closed:

Whether the discharge / concentric system is placed correctly.

Whether the channels, fixing brackets and possible clip bindings, which cannot be reached after installation, 
are fastened by means of self-tapping screws.

 

Ø

Do not plaster on or over the edges of the construction frame, because:

The heat of the appliance could cause cracks.

It will no longer be possible to remove/place the glass pane.

Ø

When using stone-like materials and/or plaster finishing, allow the chimney breast to dry for at least six weeks 
prior to taking the appliance into operation in order to prevent cracks.

5.7 Placing the control hatch

 (if applicable)

The control hatch (also see paragraphs 5.5 and 5.6) is placed as low as possible in the chimney breast.
 

!Caution

The bottom of the control hatch may not be placed higher in the appliance than the burner surface.

Place control hatch and bracket with gas control indoors in a dry place only!

 
A number of components are placed in the control hatch, such as data plate, gas control and, if applicable, the 
components belonging to the DRU Powervent System

®

.

Place the control hatch as follows, see Appendix 3, Fig. 3 for details:

Ø

Make an opening in the chimney breast, as described in the manual for the control hatch.

8

Содержание 0063CM3071

Страница 1: ...g l i s h Store this document in a safe place Metro 130XT 41 RCH Metro 130XT 41 Tunnel RCH Installation manual DRU 667777 EN US 0420 8 G20 G25 G25 3 Natural gas G30 Butane and G31 Propane EN 959 073 0...

Страница 2: ...st 5 7 Placing the control hatch 5 8 Concentric system 5 9 Connection to an existing chimney C91 5 10 Additional instructions 5 11 Glass panes 5 11 1 Removing the glass pane 5 11 2 Placing the glass p...

Страница 3: ...system or DRU CM system the accompanying installation manual should also be read completely and carefully before installation work is started The following symbols are used in the manuals to indicate...

Страница 4: ...wiring Place heat resistant electrical wiring away from the appliance and as low as possible in the chimney breast This has to do with the temperature development in the chimney breast Only use the fl...

Страница 5: ...ally by means of the remote control In case of switching on manually the appliance will first return to full load Caution The appliance s control unit is characterized by stringent safety requirements...

Страница 6: ...ection may only be mounted vertically so that the gas hose can be connected vertically at the bottom The gas connection is permitted in a zone blue hatched area in the figure To the left and right of...

Страница 7: ...to account The minimum construction measurements according to Appendix 3 Fig 1 and 2 The construction height of the appliance Provide a gas connection at the location For details see section 5 2 Make...

Страница 8: ...nimum 30 cm distance between the top of the ventilation hole outgoing and the ceiling of the house The measurements of the glass pane so that it can be placed removed after placing the chimney breast...

Страница 9: ...t of the control hatch Connect the 230V mains voltage with protective earth using the correct type of plug The other side of the power cable can be easily connected to the universal 230V plug in the c...

Страница 10: ...ngth 3 Count the total number of metres of vertical and or sloping pipe length roof terminal excluded 4 In the first 2 columns of Table 5 look for the number of bends required and the total horizontal...

Страница 11: ...ide by means of four screws Caution When using the wall terminal place the terminal with a downward slope of 1 cm metre towards the outside in order to prevent rain water from raining in 5 9 Connectio...

Страница 12: ...r see appendix 3 fig 8 Hold the glass pane at both sides and pull the glass pane towards you by a maximum of 1 cm see appendix 3 fig 9 Lightly press the glass pane down and push the glass pane in the...

Страница 13: ...ns B to D in appendix 2 table 6 The letter for the position on the restrictor slide corresponds with the letter of the situation in table 6 Make sure that the point of the triangle belonging to the po...

Страница 14: ...r is kept free from objects make sure there is no vermiculite s dust on the burner 5 13 1 Wood set The wood set consists of vermiculite see Appendix 3 fig 19 chips see Appendix 3 fig 20 glow material...

Страница 15: ...Appendix 3 fig 29 Fill the burner with vermiculite spread the vermiculite evenly see Appendix 3 fig 30 Caution You can influence the flame picture by moving the vermiculite yet the burner deck has to...

Страница 16: ...emote control it is possible to read all information stored in the receiver In this way the last 20 error messages can be retrieved and it will also be possible to read how many times an error occurre...

Страница 17: ...e by means of an RJ45 plug according to the instructions in the manual that is supplied with this module Now follow the steps described in the modbus protocol manual It is available from the supplier...

Страница 18: ...e until the main burner ignites Caution After each attempt to ignite the system should be reset by means of the remote control Consult the diagram with error messages Appendix 1 if this does not succe...

Страница 19: ...tion of the main burner does not comply with the above mentioned requirements 7 4 Flame picture The flame picture can only really be assessed when the appliance has been burning for several hours Vola...

Страница 20: ...l against unintended ignition by other wireless remote controls such as car keys and garage door openers Point out the 230 Volt connection Instruct the user about the appliance and the remote control...

Страница 21: ...ctly Ionization pin blocked measure ionization flow when 0 and 1 8 uA Ionization pin defective measure ionization current when 0 Make sure the connectors of the communication cable make proper contact...

Страница 22: ...defective Diff pressure hoses leak Diff pr sensor defective Ctrl signal cable defective Concentric system defective and or leaking ESYS defective burner device Premature interruption ignition cycle al...

Страница 23: ...strictor slide Remote control Mains lead Control hatch Back up self tapping screws for benefit of glass pane assembly Key bolts Hexagonal nut M8 Washer M8 Compression fitting 15 mm x G3 8 Socket spann...

Страница 24: ...kW G30 No 11 8 107 3 11 8 6 0 15 8 14 6 448 256 25 1 8 1 3x 1 20 A 1 89 6 84 6 0 0236 0 0125 0 0026 89 A Type of heat output room temperature control Single stage heat output no room temperature contr...

Страница 25: ...pipe length excluding wall terminal 0 12 2 5 Table 4 Conditions for setting the appliance See Figure 5 5 Air inlet guide G20 G25 G25 3 YES 1 2 YES 2 Air inlet guide G30 G31 YES 2 NO Restrictor slide...

Страница 26: ...imum length Situation A B C D Air inlet guide G20 G25 G25 3 YES 2 YES 1 2 YES 1 2 YES 1 2 Table 6 Conditions for the adjustment of the appliance with a roof terminal Air inlet guide G30 G31 NO YES 2 Y...

Страница 27: ...igures 27 min 856 max 876 50 1304 390 174 407 5 428 min 216 max 236 30 38C 2132 0 1520 1365 130 200 B B Metro 130XT 41 RCH 1304 390 50 min 855 5 max 876 min 216 max 236 428 476 30 30 38C 2133 0 1365 1...

Страница 28: ...l i s h INSTALLATION MANUAL 28 min 350 432 min 220 1369 min 15 max 100 min 1630 min 410 Metro 130XT min 476 Metro 130XT Tunnel V Tot min 200cm2 2 2 A 2 2 B 38C 2134 0 A B C G F D A E H B 38C 1747 b 0...

Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 2 5m 38c 744o 1x90 0 8 4m 0 1m 38c 744p 1x90 5 4 5...

Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 T U 2 1 38C 1897 0 X 3 7...

Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38C 2135 0 S T U R 38C 1898 0 MAX 1CM 38C 1899 0 1 P 2 Y 38C 1900 0 38C 1901 0 12 8 9 10 11...

Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 B N P 1 2 12x 38c 2136 0 13...

Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0263 38P 0432 38P 0433 38P 0434 38p 0022 38p 0023 38P 0028 1 19 15 16 20 17 21 18...

Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 23 22...

Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 24 25 26...

Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0529 0 38P 0530 0 38c 1657 0 27 28 29...

Страница 37: ...E n g l i s h INSTALLATION MANUAL 37 38p 0448 38p 0440 38p 0441 32 30 31...

Страница 38: ...E n g l i s h INSTALLATION MANUAL 38 38C 1871 0 Modbus WiFi Router W R D B O A 0 3 V L N L N 0 3V C D B 38P 0790 0 max 0 5A 250VAC 30VDC max 80W 230VAC A PowerVent 36 35...

Страница 39: ...E n g l i s h INSTALLATION MANUAL 39 1 98 Off 1 98 Off B2 B1 B U B U C B D 38p 0319 2 P1 P2 G IN A 38 37...

Страница 40: ...E n g l i s h INSTALLATION MANUAL UK Min 12 5 mm Min 12 5 mm 38C 2321 0 Min 100 mm Min 100 mm Min 60 mm Min 60 mm Min 0 mm Min 0 mm 38C 2311 0 40 41...

Страница 41: ...E n g l i s h INSTALLATION MANUAL 41 300 mm 38C 2605 20 mm 20 mm R 40 mm 270 mm 38C 2607 43 42...

Страница 42: ...E n g l i s h INSTALLATION MANUAL 42...

Страница 43: ...E n g l i s h INSTALLATION MANUAL 43...

Страница 44: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...

Отзывы: