I N STA LLAT IO N M AN UAL

!Caution

This appliance has 3 adjustable rings, make sure all 3 rings are adjusted correctly.

Ø

Place the vermiculite tray back in the appliance and fasten it with the self-tapping screws.

Ø

The G20 data no longer apply if the appliance is set to G25/G25.3. For that reason, you should place the supplied 
sticker (see appendix 3, fig. 39) over the G20 data of the type plate.

!Caution

Gas G20 on a G25/G25.3 setting will result in poor combustion, leading to hazardous situations.

5.13 Placing the wood/pebble set

The appliance is supplied with a wood set or a pebble set.
The vermiculite that is used to fill the burner is black when using the wood set and has a natural colour when 
using the pebble set.

!Caution

The figures do not always show the correct colours.

!Caution

Strictly observe the following instructions to prevent unsafe situations:

Ø

only ever use the supplied wood/pebble set;

Ø

only use the glow material (see appendix 3, fig. 21) in combination with the wood set;

Ø

place the wood/pebble set exactly as described;

Ø

make sure the ionization and spark electrodes and the surrounding space remain free
(see Appendix 3, fig. 15 up to 18);

Ø

make sure that the slot between the burner tray and the tray surrounding the burner is kept free from objects;

Ø

make sure there is no vermiculite's dust on the burner.

5.13.1 Wood set

The wood set consists of vermiculite (see Appendix 3, fig. 19), chips (see Appendix 3, fig. 20), glow material
(see Appendix 3, Fig. 21) and a number of branches (see Appendix 3, fig. 22).

!Caution

The figures do not always show the correct colours.

Ø

Remove the frame from the vermiculite tray (see Appendix 3, fig. 23).

Ø

Fill the burner with vermiculite; spread the vermiculite evenly (see Appendix 3, fig. 23). The vermiculite may not 
come higher than the edge of the burner.

!Caution

You can influence the flame picture by moving the vermiculite, yet

the burner deck has to remain covered with vermiculite in order to prevent that the life span of the burner is 
reduced.

Ø

Fill the vermiculite tray with chips; spread the chips evenly (see Appendix 3, fig. 23).

Ø

Identify branches A up to H (see Appendix 3, fig. 22).

!Tip

Use the burn stains on the branches for identification.

Ø

Place branch A across the burner, place the ridge of the branch on the positioning bracket
(see Appendix 3, fig. 24).

Ø

Proceed with branches B, C, D and E (see Appendix 3, fig. 25).

Ø

Then place branches F up to H (see Appendix 3, fig 26).

!Caution

The branches may not completely cover the burner pattern (see Appendix 3, fig. 27 + 28), because:

the main burner will not ignite properly; which could result in unsafe situations;

the appliance will become filthy more quickly, as a result of soot;

the flame picture will be affected.

14

Содержание 0063CM3071

Страница 1: ...g l i s h Store this document in a safe place Metro 130XT 41 RCH Metro 130XT 41 Tunnel RCH Installation manual DRU 667777 EN US 0420 8 G20 G25 G25 3 Natural gas G30 Butane and G31 Propane EN 959 073 0...

Страница 2: ...st 5 7 Placing the control hatch 5 8 Concentric system 5 9 Connection to an existing chimney C91 5 10 Additional instructions 5 11 Glass panes 5 11 1 Removing the glass pane 5 11 2 Placing the glass p...

Страница 3: ...system or DRU CM system the accompanying installation manual should also be read completely and carefully before installation work is started The following symbols are used in the manuals to indicate...

Страница 4: ...wiring Place heat resistant electrical wiring away from the appliance and as low as possible in the chimney breast This has to do with the temperature development in the chimney breast Only use the fl...

Страница 5: ...ally by means of the remote control In case of switching on manually the appliance will first return to full load Caution The appliance s control unit is characterized by stringent safety requirements...

Страница 6: ...ection may only be mounted vertically so that the gas hose can be connected vertically at the bottom The gas connection is permitted in a zone blue hatched area in the figure To the left and right of...

Страница 7: ...to account The minimum construction measurements according to Appendix 3 Fig 1 and 2 The construction height of the appliance Provide a gas connection at the location For details see section 5 2 Make...

Страница 8: ...nimum 30 cm distance between the top of the ventilation hole outgoing and the ceiling of the house The measurements of the glass pane so that it can be placed removed after placing the chimney breast...

Страница 9: ...t of the control hatch Connect the 230V mains voltage with protective earth using the correct type of plug The other side of the power cable can be easily connected to the universal 230V plug in the c...

Страница 10: ...ngth 3 Count the total number of metres of vertical and or sloping pipe length roof terminal excluded 4 In the first 2 columns of Table 5 look for the number of bends required and the total horizontal...

Страница 11: ...ide by means of four screws Caution When using the wall terminal place the terminal with a downward slope of 1 cm metre towards the outside in order to prevent rain water from raining in 5 9 Connectio...

Страница 12: ...r see appendix 3 fig 8 Hold the glass pane at both sides and pull the glass pane towards you by a maximum of 1 cm see appendix 3 fig 9 Lightly press the glass pane down and push the glass pane in the...

Страница 13: ...ns B to D in appendix 2 table 6 The letter for the position on the restrictor slide corresponds with the letter of the situation in table 6 Make sure that the point of the triangle belonging to the po...

Страница 14: ...r is kept free from objects make sure there is no vermiculite s dust on the burner 5 13 1 Wood set The wood set consists of vermiculite see Appendix 3 fig 19 chips see Appendix 3 fig 20 glow material...

Страница 15: ...Appendix 3 fig 29 Fill the burner with vermiculite spread the vermiculite evenly see Appendix 3 fig 30 Caution You can influence the flame picture by moving the vermiculite yet the burner deck has to...

Страница 16: ...emote control it is possible to read all information stored in the receiver In this way the last 20 error messages can be retrieved and it will also be possible to read how many times an error occurre...

Страница 17: ...e by means of an RJ45 plug according to the instructions in the manual that is supplied with this module Now follow the steps described in the modbus protocol manual It is available from the supplier...

Страница 18: ...e until the main burner ignites Caution After each attempt to ignite the system should be reset by means of the remote control Consult the diagram with error messages Appendix 1 if this does not succe...

Страница 19: ...tion of the main burner does not comply with the above mentioned requirements 7 4 Flame picture The flame picture can only really be assessed when the appliance has been burning for several hours Vola...

Страница 20: ...l against unintended ignition by other wireless remote controls such as car keys and garage door openers Point out the 230 Volt connection Instruct the user about the appliance and the remote control...

Страница 21: ...ctly Ionization pin blocked measure ionization flow when 0 and 1 8 uA Ionization pin defective measure ionization current when 0 Make sure the connectors of the communication cable make proper contact...

Страница 22: ...defective Diff pressure hoses leak Diff pr sensor defective Ctrl signal cable defective Concentric system defective and or leaking ESYS defective burner device Premature interruption ignition cycle al...

Страница 23: ...strictor slide Remote control Mains lead Control hatch Back up self tapping screws for benefit of glass pane assembly Key bolts Hexagonal nut M8 Washer M8 Compression fitting 15 mm x G3 8 Socket spann...

Страница 24: ...kW G30 No 11 8 107 3 11 8 6 0 15 8 14 6 448 256 25 1 8 1 3x 1 20 A 1 89 6 84 6 0 0236 0 0125 0 0026 89 A Type of heat output room temperature control Single stage heat output no room temperature contr...

Страница 25: ...pipe length excluding wall terminal 0 12 2 5 Table 4 Conditions for setting the appliance See Figure 5 5 Air inlet guide G20 G25 G25 3 YES 1 2 YES 2 Air inlet guide G30 G31 YES 2 NO Restrictor slide...

Страница 26: ...imum length Situation A B C D Air inlet guide G20 G25 G25 3 YES 2 YES 1 2 YES 1 2 YES 1 2 Table 6 Conditions for the adjustment of the appliance with a roof terminal Air inlet guide G30 G31 NO YES 2 Y...

Страница 27: ...igures 27 min 856 max 876 50 1304 390 174 407 5 428 min 216 max 236 30 38C 2132 0 1520 1365 130 200 B B Metro 130XT 41 RCH 1304 390 50 min 855 5 max 876 min 216 max 236 428 476 30 30 38C 2133 0 1365 1...

Страница 28: ...l i s h INSTALLATION MANUAL 28 min 350 432 min 220 1369 min 15 max 100 min 1630 min 410 Metro 130XT min 476 Metro 130XT Tunnel V Tot min 200cm2 2 2 A 2 2 B 38C 2134 0 A B C G F D A E H B 38C 1747 b 0...

Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 2 5m 38c 744o 1x90 0 8 4m 0 1m 38c 744p 1x90 5 4 5...

Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 T U 2 1 38C 1897 0 X 3 7...

Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38C 2135 0 S T U R 38C 1898 0 MAX 1CM 38C 1899 0 1 P 2 Y 38C 1900 0 38C 1901 0 12 8 9 10 11...

Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 B N P 1 2 12x 38c 2136 0 13...

Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0263 38P 0432 38P 0433 38P 0434 38p 0022 38p 0023 38P 0028 1 19 15 16 20 17 21 18...

Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 23 22...

Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 24 25 26...

Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0529 0 38P 0530 0 38c 1657 0 27 28 29...

Страница 37: ...E n g l i s h INSTALLATION MANUAL 37 38p 0448 38p 0440 38p 0441 32 30 31...

Страница 38: ...E n g l i s h INSTALLATION MANUAL 38 38C 1871 0 Modbus WiFi Router W R D B O A 0 3 V L N L N 0 3V C D B 38P 0790 0 max 0 5A 250VAC 30VDC max 80W 230VAC A PowerVent 36 35...

Страница 39: ...E n g l i s h INSTALLATION MANUAL 39 1 98 Off 1 98 Off B2 B1 B U B U C B D 38p 0319 2 P1 P2 G IN A 38 37...

Страница 40: ...E n g l i s h INSTALLATION MANUAL UK Min 12 5 mm Min 12 5 mm 38C 2321 0 Min 100 mm Min 100 mm Min 60 mm Min 60 mm Min 0 mm Min 0 mm 38C 2311 0 40 41...

Страница 41: ...E n g l i s h INSTALLATION MANUAL 41 300 mm 38C 2605 20 mm 20 mm R 40 mm 270 mm 38C 2607 43 42...

Страница 42: ...E n g l i s h INSTALLATION MANUAL 42...

Страница 43: ...E n g l i s h INSTALLATION MANUAL 43...

Страница 44: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...

Отзывы: