I N STA LLAT IO N M AN UAL

5.    Installation

5.1 Type of gas

The data plate indicates for which type of gas, gas pressure and for which country this appliance is intended.
The data plate can be found on the appliance or can be attached to a chain to which it should remain attached.

!Caution

Check whether the appliance is suitable for the type of gas and gas pressure used at the location.
 

5.1.1 Reconstruction to different type of gas

In order to convert this appliance to a different type of gas, please contact DRU's service department and ask for 
the possibilities.

5.2 Gas connection

Place a gas tap in the gas pipe in accordance with the applicable regulations.
The gas connection on the gas control is located next to the receiver (see Appendix 3, fig. 38 (G)).
 

!Caution

Make sure there is no dirt in the gas pipes and connections.

No soldering may take place at the flexible gas hose(s), as this could cause leaks.

 
The following requirements apply to the gas connection:

Use a gas pipe with the correct dimensions, so that no pressure loss can occur.

The gas tap must be approved (in the EU this will be the CE mark).

You should always be able to reach the gas tap.

 

5.2.1 Gas hose for gas connection

In many cases, a gas hose for a gas connection according to EN14800 can be ordered together with the appliance 
(consult druservice). The gas hose is mounted to the appliance and has been checked for leak-tightness. This gas 
hose is available in different lengths.

!Caution

Take the following into account when installing the gas connection and the appliance (see Appendix 3, fig. 42 and 
43):

The gas connection must always be accessible to be able to shut off the gas supply.

The gas connection may only be mounted vertically, so that the gas hose can be connected vertically at the 
bottom.

The gas connection is permitted in a zone (blue hatched area in the figure):
- To the left and right of the appliance to a height of 30 cm above the bottom side of the appliance (the 
bottom side is the end of the adjustable feet holder, without the feet). 
- Under the appliance in the area between the legs.

The gas connection and gas hose should not be placed behind the appliance.

The gas hose may not get above the bottom side of the appliance (the bottom side is the end of the foot 
without the adjustable feet)

The minimum bend radius of the hose is 40 mm.

The hose should be placed as low as possible, must have a minimum distance from the appliance of 20 mm 
and, if possible, should not be placed under the burner.

The entrance of the gas control in which the hose is mounted faces the appliance. Due to the required 
minimum bend radius, the chimney breast width becomes larger on the side of the control hatch. With this 
gas hose, the depth of the control hatch is not 230 mm, but will now be 270 mm.

5.3 Electric connection

In case of a 230 Volt electrical connection, provide proper grounding. Place this electrical connection away from 
the appliance, as low as possible in the chimney breast. This has to do with the temperature development in the 
chimney breast.

!Caution

Make sure that it is easy to disconnect the appliance from the power supply after installation;

by disconnecting the plug;

or by means of a 2-core switch installed by a recognised installer in accordance with current regulations.

!Caution

Protect the gas control and electric components, hereafter referred to as the gas control, against building 
dust and moisture!

For connecting the receiver and control panel at an appliance equipped with the CM system

®

, you must 

observe the instructions in the supplied manual.

6

Содержание 0063CM3071

Страница 1: ...g l i s h Store this document in a safe place Metro 130XT 41 RCH Metro 130XT 41 Tunnel RCH Installation manual DRU 667777 EN US 0420 8 G20 G25 G25 3 Natural gas G30 Butane and G31 Propane EN 959 073 0...

Страница 2: ...st 5 7 Placing the control hatch 5 8 Concentric system 5 9 Connection to an existing chimney C91 5 10 Additional instructions 5 11 Glass panes 5 11 1 Removing the glass pane 5 11 2 Placing the glass p...

Страница 3: ...system or DRU CM system the accompanying installation manual should also be read completely and carefully before installation work is started The following symbols are used in the manuals to indicate...

Страница 4: ...wiring Place heat resistant electrical wiring away from the appliance and as low as possible in the chimney breast This has to do with the temperature development in the chimney breast Only use the fl...

Страница 5: ...ally by means of the remote control In case of switching on manually the appliance will first return to full load Caution The appliance s control unit is characterized by stringent safety requirements...

Страница 6: ...ection may only be mounted vertically so that the gas hose can be connected vertically at the bottom The gas connection is permitted in a zone blue hatched area in the figure To the left and right of...

Страница 7: ...to account The minimum construction measurements according to Appendix 3 Fig 1 and 2 The construction height of the appliance Provide a gas connection at the location For details see section 5 2 Make...

Страница 8: ...nimum 30 cm distance between the top of the ventilation hole outgoing and the ceiling of the house The measurements of the glass pane so that it can be placed removed after placing the chimney breast...

Страница 9: ...t of the control hatch Connect the 230V mains voltage with protective earth using the correct type of plug The other side of the power cable can be easily connected to the universal 230V plug in the c...

Страница 10: ...ngth 3 Count the total number of metres of vertical and or sloping pipe length roof terminal excluded 4 In the first 2 columns of Table 5 look for the number of bends required and the total horizontal...

Страница 11: ...ide by means of four screws Caution When using the wall terminal place the terminal with a downward slope of 1 cm metre towards the outside in order to prevent rain water from raining in 5 9 Connectio...

Страница 12: ...r see appendix 3 fig 8 Hold the glass pane at both sides and pull the glass pane towards you by a maximum of 1 cm see appendix 3 fig 9 Lightly press the glass pane down and push the glass pane in the...

Страница 13: ...ns B to D in appendix 2 table 6 The letter for the position on the restrictor slide corresponds with the letter of the situation in table 6 Make sure that the point of the triangle belonging to the po...

Страница 14: ...r is kept free from objects make sure there is no vermiculite s dust on the burner 5 13 1 Wood set The wood set consists of vermiculite see Appendix 3 fig 19 chips see Appendix 3 fig 20 glow material...

Страница 15: ...Appendix 3 fig 29 Fill the burner with vermiculite spread the vermiculite evenly see Appendix 3 fig 30 Caution You can influence the flame picture by moving the vermiculite yet the burner deck has to...

Страница 16: ...emote control it is possible to read all information stored in the receiver In this way the last 20 error messages can be retrieved and it will also be possible to read how many times an error occurre...

Страница 17: ...e by means of an RJ45 plug according to the instructions in the manual that is supplied with this module Now follow the steps described in the modbus protocol manual It is available from the supplier...

Страница 18: ...e until the main burner ignites Caution After each attempt to ignite the system should be reset by means of the remote control Consult the diagram with error messages Appendix 1 if this does not succe...

Страница 19: ...tion of the main burner does not comply with the above mentioned requirements 7 4 Flame picture The flame picture can only really be assessed when the appliance has been burning for several hours Vola...

Страница 20: ...l against unintended ignition by other wireless remote controls such as car keys and garage door openers Point out the 230 Volt connection Instruct the user about the appliance and the remote control...

Страница 21: ...ctly Ionization pin blocked measure ionization flow when 0 and 1 8 uA Ionization pin defective measure ionization current when 0 Make sure the connectors of the communication cable make proper contact...

Страница 22: ...defective Diff pressure hoses leak Diff pr sensor defective Ctrl signal cable defective Concentric system defective and or leaking ESYS defective burner device Premature interruption ignition cycle al...

Страница 23: ...strictor slide Remote control Mains lead Control hatch Back up self tapping screws for benefit of glass pane assembly Key bolts Hexagonal nut M8 Washer M8 Compression fitting 15 mm x G3 8 Socket spann...

Страница 24: ...kW G30 No 11 8 107 3 11 8 6 0 15 8 14 6 448 256 25 1 8 1 3x 1 20 A 1 89 6 84 6 0 0236 0 0125 0 0026 89 A Type of heat output room temperature control Single stage heat output no room temperature contr...

Страница 25: ...pipe length excluding wall terminal 0 12 2 5 Table 4 Conditions for setting the appliance See Figure 5 5 Air inlet guide G20 G25 G25 3 YES 1 2 YES 2 Air inlet guide G30 G31 YES 2 NO Restrictor slide...

Страница 26: ...imum length Situation A B C D Air inlet guide G20 G25 G25 3 YES 2 YES 1 2 YES 1 2 YES 1 2 Table 6 Conditions for the adjustment of the appliance with a roof terminal Air inlet guide G30 G31 NO YES 2 Y...

Страница 27: ...igures 27 min 856 max 876 50 1304 390 174 407 5 428 min 216 max 236 30 38C 2132 0 1520 1365 130 200 B B Metro 130XT 41 RCH 1304 390 50 min 855 5 max 876 min 216 max 236 428 476 30 30 38C 2133 0 1365 1...

Страница 28: ...l i s h INSTALLATION MANUAL 28 min 350 432 min 220 1369 min 15 max 100 min 1630 min 410 Metro 130XT min 476 Metro 130XT Tunnel V Tot min 200cm2 2 2 A 2 2 B 38C 2134 0 A B C G F D A E H B 38C 1747 b 0...

Страница 29: ...E n g l i s h INSTALLATION MANUAL 29 38C 1868 d 0 0 8 4m 2 5m 38c 744o 1x90 0 8 4m 0 1m 38c 744p 1x90 5 4 5...

Страница 30: ...E n g l i s h INSTALLATION MANUAL 30 T U 2 1 38C 1897 0 X 3 7...

Страница 31: ...E n g l i s h INSTALLATION MANUAL 31 38C 2135 0 S T U R 38C 1898 0 MAX 1CM 38C 1899 0 1 P 2 Y 38C 1900 0 38C 1901 0 12 8 9 10 11...

Страница 32: ...E n g l i s h INSTALLATION MANUAL 32 B N P 1 2 12x 38c 2136 0 13...

Страница 33: ...E n g l i s h INSTALLATION MANUAL 33 38P 0263 38P 0432 38P 0433 38P 0434 38p 0022 38p 0023 38P 0028 1 19 15 16 20 17 21 18...

Страница 34: ...E n g l i s h INSTALLATION MANUAL 34 38P 0169 C B D E F G H A 38p 0443 23 22...

Страница 35: ...E n g l i s h INSTALLATION MANUAL 35 38P 0442 A C B E 38p 0444 D F G H 38P 0445 24 25 26...

Страница 36: ...E n g l i s h INSTALLATION MANUAL 36 38P 0529 0 38P 0530 0 38c 1657 0 27 28 29...

Страница 37: ...E n g l i s h INSTALLATION MANUAL 37 38p 0448 38p 0440 38p 0441 32 30 31...

Страница 38: ...E n g l i s h INSTALLATION MANUAL 38 38C 1871 0 Modbus WiFi Router W R D B O A 0 3 V L N L N 0 3V C D B 38P 0790 0 max 0 5A 250VAC 30VDC max 80W 230VAC A PowerVent 36 35...

Страница 39: ...E n g l i s h INSTALLATION MANUAL 39 1 98 Off 1 98 Off B2 B1 B U B U C B D 38p 0319 2 P1 P2 G IN A 38 37...

Страница 40: ...E n g l i s h INSTALLATION MANUAL UK Min 12 5 mm Min 12 5 mm 38C 2321 0 Min 100 mm Min 100 mm Min 60 mm Min 60 mm Min 0 mm Min 0 mm 38C 2311 0 40 41...

Страница 41: ...E n g l i s h INSTALLATION MANUAL 41 300 mm 38C 2605 20 mm 20 mm R 40 mm 270 mm 38C 2607 43 42...

Страница 42: ...E n g l i s h INSTALLATION MANUAL 42...

Страница 43: ...E n g l i s h INSTALLATION MANUAL 43...

Страница 44: ...E n g l i s h DRU Verwarming B V The Netherlands Postbus 1021 NL 6920 BA Duiven Ratio 8 NL 6921 RW Duiven EN...

Отзывы: