DISPENSE MODE PARAMETERS
Parameter
Display
Description
Operation
Default
Number of Pump
Cycles
Number of pump cycles performed
when lubricating/dispensing. From 1 to
9999
Set the value using the
and keys
1
Pump On
The amount of time the pump remains
ON when dispensing.
Range: 0.1s to 9.9s
Set the value using the
and keys
1
Pump Off
The amount of time the pump remains
OFF when dispensing
Range : 0.3 to 9.9 s.
Set the value using the
and keys
1
Number of Micro-
Pumps
Number of Micropumps installed on
the system with Flow Sensing. Setting
this to 0 will disable flow sensing on all
micropumps. If you set less than the
number of micropumps installed than
the nearest ones will be monitored,
while the furthest will remain
unmonitored. EG. Setting 5 of a 6
pump system will result in the last
pump not being monitored..
Set the value using the
and keys
Min. 0
Max. 6
Min air pressure
Minimum Air Pressure monitoring
during cycle. Setting 0.0 disables
minimum air pressure monitoring.
Range 0.0-7.0 bar.
Set the value using the
and keys
0.0
Max Air Pressure
Maximum Air Pressure parameter
during cycle. Setting 0.0 disables
monitoring.Range 0.0-7.0 bar
Set the value using the
and keys
2.5
Standby Impulses
Number of impulses required to
initiate the Lubrication/Dispensing
Cycle.
Settable from 0001 to 9999.
Set the value using the
and keys
3