14. OPERATING HAZARDS 

 

It is necessary to read and understand the possible hazards and risks involved when using a lubrication pump. The 
operator must fully understand the hazards explained in this manual. 

 

Electrical Power 

No maintenance must be performed on the unit without having detached and isolated the power supply and ensuring 
that it cannot be reconnected for the duration of the maintenance task. Always remember to ensure that equipment 
is properly earthed. 

Flammable substances. 

Mineral  oils  generally  used  in  lubrication  systems  are  not  normally  flammable.  However,  it  is  desirable  to  avoid 
contact  with  extremely  hot  substances  or  naked  flames.    Ensure  that  the  machine  that  the  lubrication  system  is 
installed onto contains the necessary fire extinguishing devices. 

Pneumatic & Hydraulic Pressure  

Before any maintenance or connection task, ensure that all pressure has been properly bled from the system. Residual 
pneumatic  or  hydraulic  pressure  can  cause  the  release  of  undesired  spurts  of  liquid,  which  may  hit  the  operator. 
Always wear safety glasses and glove when working with pneumatic and hydraulic systems.  

Noise and Vibration 

The Pump does not produce excessive vibration or noise (less than 70 dB(Non si deve effettuare alcun intervento sulla 
macchina prima di aver scollegato la stessa dall’alimentazione elettrica ed  accertato che nessuno possa ricollegarla 
durante l’intervento. 
 
 

15. PRECAUTIONS  

 

 

Contact with Oil. The operator should wear protective clothing to avoid contact with the lubricant. 

 

Personnel must use personal protection equipment, clothing and tools adequate for the location and the use of 
the panel both during its operation and during maintenance operations. 

 

The  use  of  the  equipment  referred  to  in  this  manual  must  be  entrusted  to  qualified  personnel  with  a  basic 
knowledge of mechanics, hydraulics and electrical systems. 

 

It is the responsibility of the installer to use tubing suitable for the system; the use of inadequate tubing can cause 
problems with the pump, injury to persons and create pollution 

 

Loosening of connections can cause serious safety problems; carry out a check before and after installation and, if 
necessary retighten them. 

 

Never exceed the maximum working pressure values permitted for the panel and the components connected to 
it. 

 

Before any maintenance, cleaning or other operation disconnect the power supply, close off the air supply and 
discharge the pressure from inside the equipment and the tubing connected to it. 

 

Do not subject the panel, the connections, the tubing or parts under pressure to violent impacts; damaged tubing 
or  connections  are  dangerous  and  should  be  immediately  replaced  After  long  periods  of  inactivity  check  air 
tightness of all parts subjected to pressure 

 

Incompatible fluids may cause danger 

 
 

Examples of incompatible/non-permissible Fluids. 

Fluid 

Danger 

Lubricants containing abrasive components. 

Premature wear of pump 

Lubricants containing silicon. 

Pump failure 

Petrol, Solvents, flammable liquids 

Fire, explosion, seal damage. 

Corrosive products 

Pump damage, danger to persons. 

Water 

Pump oxidization  

Food Products 

Contamination of product 

 

 
 
 
 

Содержание 3135121

Страница 1: ...ION 2 GENERAL DESCRIPTION 3 MACHINE IDENTIFICATION 4 TECHNICAL CHARACTERISTICS 5 COMPONENTS 6 UNPACKING AND INSTALLING Vip4chain 7 OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 OR...

Страница 2: ...d onto a modular mixing base element This element both monitors the correct oil injection and mixing the oil into an air jet that fires it onto the lubrication point The system is completly modular an...

Страница 3: ...dular base has two functions Firstly it monitors that the pumps have correctly injected oil into the unit via a displacement sensor and secondly it injects the oil into an air stream to be carried to...

Страница 4: ...mp and base modules In the event these need to be altered or changed the pumps can be removed by taking out the 2 fixing screws as shown on the diagram bellow Ensure to place the three O Rings correct...

Страница 5: ...purchased separately Follow the diagram below to complete the electrical connection LEFT HAND SIDE CONNECTOR Used for input power and remote alarm signal BOTTOM CONNECTOR Located on the rear power box...

Страница 6: ...two modes CHAIN MODE In this mode the unit will cycle each time an impulse is received from the remote switch You can program the number of cycles in order to lubricate a chain and then the unit will...

Страница 7: ...s Number of Micropumps installed on the system with Flow Sensing Setting this to 0 will disable flow sensing on all micropumps If you set less than the number of micropumps installed than the nearest...

Страница 8: ...w sensing on all micropumps If you set less than the number of micropumps installed than the nearest ones will be monitored while the furthest will remain unmonitored EG Setting 5 of a 6 pump system w...

Страница 9: ...see the current air pressure and ensure that it is lower than the Air High setting in the set up menu Check that the tubes have not become clogged resulting in an Air High Alarm Hold the DOWN key to...

Страница 10: ...n 24 V DC Vip4chain 110 V AC 1 3135121 3135131 2 3135122 3135132 3 3135123 3135133 4 3135124 3135134 5 3135125 3135135 6 3135126 3135136 12 DIMENSIONS Allow 100 mm on each side for easy maintenance 13...

Страница 11: ...ective clothing to avoid contact with the lubricant Personnel must use personal protection equipment clothing and tools adequate for the location and the use of the panel both during its operation and...

Страница 12: ...eceipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform s...

Страница 13: ...ION DISPENSING Vip4chain o Has been manufacturer in conformance with the European Community Directive relating to the harmonised standards of the member states relating to machine safety EMC 89 336 CE...

Страница 14: ...suk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerli...

Отзывы: