DROPSA 3135121 Скачать руководство пользователя страница 4

6. UNPACKING AND INSTALLING Vip4chain 

 

6.1 UNPACKING 

Once a suitable location has been found to install the unit remove the unit from the packaging. No particular disposal 
procedures are necessary, however packing should be disposed of in accordance with regulations that may be in force 
in your area or state. 

 

6.2 INSTALLING THE UNIT 

Allow sufficient space around the unit for ease of maintenance. Install at a suitable level for refilling the oil reservoir. 
Do not install in aggressive environments. Fix the unit  using the two fixing holes and 6mm screws. 

 

6.3 ELECTRICAL WIRING 

Before carrying out any wiring, ensure that the correct power supply is available. Refer to the identification label on 
the unit and this instruction manual. 
 

6.4 INSTALLING THE MICROPUMPS ONTO THE BASE MODULE  

Normally, you will order a unit already pre-configured with the correct number of micropump and base modules. In 
the event these need to be altered or changed, the pumps can be removed by taking out the 2 fixing screws as shown 
on the diagram bellow. Ensure to place the three O-Rings correctly when installing a new pump module. 

 

 

 
 
 
 
 
 
 
 
 
 
 

 

6.5 ADDITING OR REMOVING A SUBBASE. 

The  bases  must  always  be  added  or  removed  from  the  bottom  one  first.  To  add  or  remove  a  sub-base  from  the 
Vip

4

chain unit  

 

1.

 

Disconnect  power  and  air  suppl  and  empty  the  tank  (by  removing  the  unit  and  pouring  out  the  oil  into  a 
container) 

2.

 

Disconnect the solenoid valve on the base of the unit using the three fixing screws. 

3.

 

Remove the End-plate by undoing the two fixing screws  

4.

 

Add  a  new  sub-base  (or  remove  the  existing  one)  as  shown  in  the  diagram  below.  Ensure  the  Electrical 
connector and O-rings are all in place before closing the sub base against either another  sub-base or the end-
plate 

5.

 

Add the end-plate and the solenoid valve. 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 

 

Threaded Insert 

O-Seals 

Mixing  Sub-Base 

Fixing Screws 

Electrical 
Connector 

Push-in 

Plate 

Bleed screw 

  

Bleed screw

 

 

 

Fixing screws 

Micropump 

O-Rings 

Mixing Sub 

 Base 

Содержание 3135121

Страница 1: ...ION 2 GENERAL DESCRIPTION 3 MACHINE IDENTIFICATION 4 TECHNICAL CHARACTERISTICS 5 COMPONENTS 6 UNPACKING AND INSTALLING Vip4chain 7 OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 OR...

Страница 2: ...d onto a modular mixing base element This element both monitors the correct oil injection and mixing the oil into an air jet that fires it onto the lubrication point The system is completly modular an...

Страница 3: ...dular base has two functions Firstly it monitors that the pumps have correctly injected oil into the unit via a displacement sensor and secondly it injects the oil into an air stream to be carried to...

Страница 4: ...mp and base modules In the event these need to be altered or changed the pumps can be removed by taking out the 2 fixing screws as shown on the diagram bellow Ensure to place the three O Rings correct...

Страница 5: ...purchased separately Follow the diagram below to complete the electrical connection LEFT HAND SIDE CONNECTOR Used for input power and remote alarm signal BOTTOM CONNECTOR Located on the rear power box...

Страница 6: ...two modes CHAIN MODE In this mode the unit will cycle each time an impulse is received from the remote switch You can program the number of cycles in order to lubricate a chain and then the unit will...

Страница 7: ...s Number of Micropumps installed on the system with Flow Sensing Setting this to 0 will disable flow sensing on all micropumps If you set less than the number of micropumps installed than the nearest...

Страница 8: ...w sensing on all micropumps If you set less than the number of micropumps installed than the nearest ones will be monitored while the furthest will remain unmonitored EG Setting 5 of a 6 pump system w...

Страница 9: ...see the current air pressure and ensure that it is lower than the Air High setting in the set up menu Check that the tubes have not become clogged resulting in an Air High Alarm Hold the DOWN key to...

Страница 10: ...n 24 V DC Vip4chain 110 V AC 1 3135121 3135131 2 3135122 3135132 3 3135123 3135133 4 3135124 3135134 5 3135125 3135135 6 3135126 3135136 12 DIMENSIONS Allow 100 mm on each side for easy maintenance 13...

Страница 11: ...ective clothing to avoid contact with the lubricant Personnel must use personal protection equipment clothing and tools adequate for the location and the use of the panel both during its operation and...

Страница 12: ...eceipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform s...

Страница 13: ...ION DISPENSING Vip4chain o Has been manufacturer in conformance with the European Community Directive relating to the harmonised standards of the member states relating to machine safety EMC 89 336 CE...

Страница 14: ...suk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerli...

Отзывы: