7 OPERATION  

 

7.1 COMMISIONING THE Vip4chain 

Before using the Vip

4

chain, the following check list must be observed: 

 

The Unit has not sustained any damage 

 

Electrical and Pneumatic connections are correct 

 

Purge  Air  from  the  micropumps  by  loosening  the  bleed  screw  on  the  micropumps  using  a  2mm  allen  key. 

Once oil is present, tighten the screw 

 

Power on the unit  

 

Set the operating parameters as described in this manual. 

 

To  help  purge  the  air  from  the  unit,  set  the  pumps  to  maximum  output  by  screwing  the  regulating  dial 

clockwise. 

 

7.2 ZERO-OUTPUT: 

If you want to temporarily set zero output on a pump module, you can  turn the regulating dial anti clockwise until it 
stops. Note that if you have sensing enable on the mixing base, you will obtain a pump fault alarm  
 

7.3 SETTING THE OIL OUTPUT ON THE MICROPUMPS 

Pump output is set using the red regulating dial.  
Turn the dial anti clockwise until it stops. This equals 0 mm

3

 (pump on zero-output as above). Turn the regulating dial 

2.5 turns to achieve 10mm

3

 (the output sensor will read this output). Each complete turn will now increase the pump 

output by 5mm3, to a maximum of 30mm

3

. (See following table) 

 

OUTPUT (mm³ / colpo) 

TURNS 

30 

6.5 

25 

5.5 

20 

4.5 

15 

3.5 

10 

2.5 

1.5 

0= Zero Output 

Maximum anti-clockwise 

 

7.4 PROGRAMMING THE CONTROLLER  

 
The controller can operate in two modes :  
 
CHAIN  MODE

:

  In  this  mode,  the  unit  will  cycle  each  time  an  impulse  is  received  from  the  remote  switch.  You  can 

program the number of cycles in order to lubricate a chain, and then the unit will go into standby mode. You can set 
how many impulses from the remote switch have to be detected before returning to cycle mode.  
 

DISPENSE MODE

: In this mode, when the unit cycles, it will activate the pumps for a set number of times  with an 

interval  between  each  activation.      Following  the  dispensing  cycle  the  unit  goes  into  standby  mode.  As  with  Chain 
mode,  it  will  count  a  number  of  impulses  from  a  remote  switch  (which  can  even  be  a  single  impulse)  before  it 
activates the dispensing cycle again.  
The user can set the on time and off time of the pump activation. 

 

Air Pressure regulation. 

To set the air mixing pressure hold the down key         . The air solenoid will open and the air pressure will be displayed 
on the front panel display. Use the regulator to set the desired air pressure. 
 

Normal Operation  

When the unit is powered on, it will automatically start in a standby cycle. During the standby cycle the front panel 
display  will  indicate  how  many  more  impulses  the  unit  is  expecting  before  commencing  a  lubrication  or  dispensing 
cycle. 
 
By Pressing the UP Key       , you can skip the standby cycle and activate the lubrication cycle immediately. 
 

Alarm  

In the event of an failure or alarm, the unit will display an alarm code. This can be cleared by pressing  
the               button. See the Troubleshooting section of this manual. 

 

 

Reset 

Содержание 3135121

Страница 1: ...ION 2 GENERAL DESCRIPTION 3 MACHINE IDENTIFICATION 4 TECHNICAL CHARACTERISTICS 5 COMPONENTS 6 UNPACKING AND INSTALLING Vip4chain 7 OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 OR...

Страница 2: ...d onto a modular mixing base element This element both monitors the correct oil injection and mixing the oil into an air jet that fires it onto the lubrication point The system is completly modular an...

Страница 3: ...dular base has two functions Firstly it monitors that the pumps have correctly injected oil into the unit via a displacement sensor and secondly it injects the oil into an air stream to be carried to...

Страница 4: ...mp and base modules In the event these need to be altered or changed the pumps can be removed by taking out the 2 fixing screws as shown on the diagram bellow Ensure to place the three O Rings correct...

Страница 5: ...purchased separately Follow the diagram below to complete the electrical connection LEFT HAND SIDE CONNECTOR Used for input power and remote alarm signal BOTTOM CONNECTOR Located on the rear power box...

Страница 6: ...two modes CHAIN MODE In this mode the unit will cycle each time an impulse is received from the remote switch You can program the number of cycles in order to lubricate a chain and then the unit will...

Страница 7: ...s Number of Micropumps installed on the system with Flow Sensing Setting this to 0 will disable flow sensing on all micropumps If you set less than the number of micropumps installed than the nearest...

Страница 8: ...w sensing on all micropumps If you set less than the number of micropumps installed than the nearest ones will be monitored while the furthest will remain unmonitored EG Setting 5 of a 6 pump system w...

Страница 9: ...see the current air pressure and ensure that it is lower than the Air High setting in the set up menu Check that the tubes have not become clogged resulting in an Air High Alarm Hold the DOWN key to...

Страница 10: ...n 24 V DC Vip4chain 110 V AC 1 3135121 3135131 2 3135122 3135132 3 3135123 3135133 4 3135124 3135134 5 3135125 3135135 6 3135126 3135136 12 DIMENSIONS Allow 100 mm on each side for easy maintenance 13...

Страница 11: ...ective clothing to avoid contact with the lubricant Personnel must use personal protection equipment clothing and tools adequate for the location and the use of the panel both during its operation and...

Страница 12: ...eceipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform s...

Страница 13: ...ION DISPENSING Vip4chain o Has been manufacturer in conformance with the European Community Directive relating to the harmonised standards of the member states relating to machine safety EMC 89 336 CE...

Страница 14: ...suk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerli...

Отзывы: