DROPSA 3135121 Скачать руководство пользователя страница 3

5. COMPONENTS  

 

Main Unit Vip

4

chain 

Vip

4

chain  Electronic  Controller  :

  Controls  and  monitors  all  the  components  on  the  unit,  including  chain 

impulses, air pressure, oil flow, pump activations and oil level. 

Pneumatics Circuit: 

A pressure regulator and filter allows the user to fine tune the air jet to the lubrication 

point. 

An 

integrated 

air 

pressure 

transducer 

can 

monitors 

min/max 

air 

pressures. 

A solenoid valve is used to activate the micropumps at the desired intervals. 

Oil Reservoir: 

 A Clear 1 litre reservoir.  

 

Pneumatic micropumps. 

The micropumps are installed on the air/oil mixing bases. They are adjustable from 0 to 30 mm³ per cycle.  To 
increase the flow turn the pump adjusting dial clockwise, to decrease counterclockwise. 
 

Modular mixing sub-base with flow sensing. 

The modular base has two functions.  
Firstly,  it  monitors  that  the  pumps  have  correctly  injected  oil  into  the  unit  via  a  displacement  sensor  and 
secondly, it injects the oil into an air stream to be carried to the lubrication point. 
No  settings  are  required  as  the  unit  automatically  configures  itself.  A  green  LED  will  indicate  the  correct 
operation of the pump module fitted on top of the base unit. 
The  signals  are  then  sent  back  to  the  Main 

Vip

4

chain

  Controller  to  determine  that  all  the  units  are 

functioning correctly. 

 
When a lubrication cycle is in progress, the LED on the sub base indicates the flow of oil from the micropumps. During 
the standby interval the LED will remain off  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Item 

PART 

NUMBER 

DESCRIPTION 

3044335 

Reservoir 

3130139 

Filling Cap & Filter 

3155148 

Solenoid 24V DC 

3155149 

Solenoid 110V AC 

1524408 

Modular Mixing Sub-Base 

3103116 

Adjustable pneumatic Micropump 

1639118 

Wiring Box , 24V Version 

1639119 

Wiring Box, 110V Version 

3 o 4 

7 o 8 

Содержание 3135121

Страница 1: ...ION 2 GENERAL DESCRIPTION 3 MACHINE IDENTIFICATION 4 TECHNICAL CHARACTERISTICS 5 COMPONENTS 6 UNPACKING AND INSTALLING Vip4chain 7 OPERATION 8 TROUBLESHOOTING 9 MAINTENANCE PROCEDURE 10 DISPOSAL 11 OR...

Страница 2: ...d onto a modular mixing base element This element both monitors the correct oil injection and mixing the oil into an air jet that fires it onto the lubrication point The system is completly modular an...

Страница 3: ...dular base has two functions Firstly it monitors that the pumps have correctly injected oil into the unit via a displacement sensor and secondly it injects the oil into an air stream to be carried to...

Страница 4: ...mp and base modules In the event these need to be altered or changed the pumps can be removed by taking out the 2 fixing screws as shown on the diagram bellow Ensure to place the three O Rings correct...

Страница 5: ...purchased separately Follow the diagram below to complete the electrical connection LEFT HAND SIDE CONNECTOR Used for input power and remote alarm signal BOTTOM CONNECTOR Located on the rear power box...

Страница 6: ...two modes CHAIN MODE In this mode the unit will cycle each time an impulse is received from the remote switch You can program the number of cycles in order to lubricate a chain and then the unit will...

Страница 7: ...s Number of Micropumps installed on the system with Flow Sensing Setting this to 0 will disable flow sensing on all micropumps If you set less than the number of micropumps installed than the nearest...

Страница 8: ...w sensing on all micropumps If you set less than the number of micropumps installed than the nearest ones will be monitored while the furthest will remain unmonitored EG Setting 5 of a 6 pump system w...

Страница 9: ...see the current air pressure and ensure that it is lower than the Air High setting in the set up menu Check that the tubes have not become clogged resulting in an Air High Alarm Hold the DOWN key to...

Страница 10: ...n 24 V DC Vip4chain 110 V AC 1 3135121 3135131 2 3135122 3135132 3 3135123 3135133 4 3135124 3135134 5 3135125 3135135 6 3135126 3135136 12 DIMENSIONS Allow 100 mm on each side for easy maintenance 13...

Страница 11: ...ective clothing to avoid contact with the lubricant Personnel must use personal protection equipment clothing and tools adequate for the location and the use of the panel both during its operation and...

Страница 12: ...eceipt of subject product to an authorized Dropsa Sales Service location we will then either repair or replace such product s at out option and if determined to be a warranted defect we will perform s...

Страница 13: ...ION DISPENSING Vip4chain o Has been manufacturer in conformance with the European Community Directive relating to the harmonised standards of the member states relating to machine safety EMC 89 336 CE...

Страница 14: ...suk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerli...

Отзывы: