background image

7 of 10 

 

INDICATION 

PROBABLE CAUSE 

REMEDY 

 

The pump does not deliver oil or 
does not deliver oil in the exact 
quantity prescribed  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The pump does not deliver oil at 
the prescribed pressure 

 

 

The oil in the tank is below the 
minimum level 

 

 

The suction filter is dirty or 
blocked 

 

 

The pump control valve fails to 
discharge 

 
 
 

 

The internal connections are 
loose 

 
 
 
 

 

The command fluid pressure is 
insufficient 

 

 

Fill the tank with oil without 
exceeding the MAX level line 

 

 

Open the cover of the pump, 
remove the suction filter and 
clean it 

 

Check that the pump control 
valve is a 3-way type and that 
the valve regularly discharges 
fluid from the pump chamber 
when the supply is cut off. 

 

Remove the plate from the tank 
and carefully tighten all 
connections ensuring there are 
no leaks 

 
 

 

Increase the pressure on the 
command fluid to reach the 
required oil pressure value 

 

3.8 

Dangers present in use 

 
The verification of conformity with the essential safety requirements and regulations of the Machine Directive is 
effected by means of the compilation of a check list which has been pre-prepared and is contained in the 

technical 

file.

 

The lists which are utilised are of three types: 

 

list of dangers (as in EN 414 referring to EN 292) 

 

application of essential safety requirements (Machine Dir.) 

 

electrical safety requirements (EN 60204-1) 

The following is a list of dangers which have not been fully eliminated but which are considered acceptable: 

 

in the version of the pump without a release it is possible to encounter squirts of oil (for this reason 
appropriate protective clothing must be worn) 

 

contact with oil -> see the requirements for the use of suitable personal protective clothing 

 

use of unsuitable lubricant -> the characteristics of the fluid are shown on the pump and in the manual 
(

in case of doubt contact the Eng. Dept of Dropsa Spa

)

 

 

protection against direct and indirect contact must be provided by the user 

 

given  the  purpose  of  the  pump  it  must  always  be  functioning;  for  this  reason  it  is  necessary  to  pay 
attention to the electrical connections which, in the case of a power failure, the customer’s machine is 
restarted only by means of a reset, while the lubrication pump is able to restart 

 
 

INADMISSIBLE FLUIDS 

Fluids 

Fluids 

Lubricants with abrasive additives 

Lubricants with abrasive additives 

Lubricants with silicone based additives 

Lubricants with silicone based additives 

Petrol – solvents – inflammable liquids 

Petrol – solvents – inflammable liquids 

Corrosive products 

Corrosive products 

Water 

Water 

Food substances 

Food substances 

 

Содержание 31070 Series

Страница 1: ...nslation Warranty Information CONTENT 0 0 INTRODUCTION 1 0 DESCRIPTION OF THE PUMP 2 0 TECHNICAL SPECIFICATIONS 3 0 CORRECT USE 4 0 DIMENSIONS 5 0 DECLARATION OF CONFORMITY 6 0 DISTRIBUTORS The manual...

Страница 2: ...connections can cause serious safety problems and all such connections should be checked before and after installation and tightened if necessary Never exceed the maximum operating pressure values al...

Страница 3: ...s available with characteristics Part number pressure c c stroke tank syst ratio min level weight dimensions min max useful max litres electric Kg lxdxh mm 3107000 15 30 7 5 15 0 4 06 1 1 no 1 54 84x9...

Страница 4: ...working temperature Between 115 2000 cSt Working temperature 5 50 C Working humidity 90 relative humidity Preservation temperature 20 50 C Sound pressure level 70 dB A Manual push button control Disc...

Страница 5: ...any level and pressure switches to the control panel The minimum level indicator is supplied unless otherwise specified by the customer with the contact closed for minimum level Should the user requir...

Страница 6: ...e springs the component parts of the pump unit can then be disassembled 5 remove the screws which retain the flange so releasing the complete pump unit In this way all component parts of the pump unit...

Страница 7: ...s list of dangers as in EN 414 referring to EN 292 application of essential safety requirements Machine Dir electrical safety requirements EN 60204 1 The following is a list of dangers which have not...

Страница 8: ...3 90 54 93 12 M10x1 M10x1 62 210 3107002 79 170 54 100 12 M14x1 5 M14x1 5 132 294 3107006 110 90 54 93 12 M10x1 M10x1 62 250 3107010 110 90 54 93 12 M10x1 M10x1 62 250 3107021 77 170 54 100 7 5 M14x1...

Страница 9: ...ne named que la machine d nomm e Die Maschine mit der Bezeichnung que la m quina denominada que o equipamento denominado SERIES 31070 HYDRAULICALLY DRIVEN PUMP conforme alle condizioni previste dalle...

Страница 10: ...esuk dropsa com Dropsa do Brazil Ind E Com Ltda Rua Sobralia 175 Sao Paulo Brazil Tel 55 011 5631 0007 Fax 55 011 5631 9408 E mail salesbr dropsa com Dropsa USA Inc 6645 Burroughs Ave 48314 2132 Srerl...