9
4.
Description of Functions
The console set-up functions are explained below. Code numbers 17 and after are selected by selecting code
No. 16 in the basic setting items. At code No. 16, one of the following three modes can be selected.
(1)
Special setting items 1 (Sp.set-1)
Code numbers 17-97 can be set.
(2)
Special setting items 2 (Sp. set-2)
Code numbers 17-31 can be set.
(3)
Optional setting items (Option)
Code numbers 17-24 can be set.
4-1
Basic Setting Items
4-1-1 Reference frequency and its range
The maximum/minimum output frequency, reference frequency, and excess frequency can be set. When the
[START] key is pressed, the motor rotates at the reference frequency.
1) No. 00
Ref (set).F
(reference frequency)
2) No. 05
Top.F
(maximum frequency)
3) No. 11
Min.F
(minimum frequency)
*4) No. 21
OF.Set
(excess frequency)
* protection is performed.
4-1-2 Jog frequency
The jog frequency can be set.
1) No. 01
FOR-JOG.F
(forward jog frequency)
2) No. 02
REV-JOG.F
(reverse jog frequency)
4-1-3 Preset frequency
Operation can be performed at preset 1 and 2 frequencies. Preset 1 or 2 can be selected by the communication
option, multifunction input (input at terminal). In program operation, preset 1 and 2 are used.
1) No. 03
Preset1.F
(preset 1 frequency)
2) No. 04
Preset2.F
(preset 2 frequency)