18 

than  4  seconds, 

 

all  the  active 

 

commands 

 

are  cancelled, 

 

although 

 

communication 

 

is 

The transmitter microprocessor receives the information from the sensor and checks the identity of  

the crane. As soon as the sensor stops receiving the signal coming from the crane, the transmitter  

LED, which was green, begins to flash in red,  (in case of belly box transmitters, a buzzer also  
sounds), in order to let the operator know that he has moved too far away. If this situation lasts  

longer 

 

maintained 

 

with  the  receiver. 

 

In this  way  the  main  contactor 

 

and the  selection 

 

orders 

 

are 

maintained. 

 

In order to return to the operating mode, all the worker has to do is move back into the working  
zone. Movement orders must be disabled in order to restart movement. Once the transmitter enters  
the working area, movement orders will not be ready to be used unless they have gone to zero.  

This is to make movements start in first speed. If the remote control is provided with a Display,  

whenever the transmitter is out of range, the message “Out of Range” will be displayed.  

 

The remote control has got 4 modes of operation defined in the EEPROM: 

 

1.- Range Limiter only at startup (Electronic Key): In order to make the transmitter work, it is  
necessary that the transmitter is inside the starting zone, defined by the position of the infrared  

transmitter. 

 

2.- Range Limiter only in operation: The transmitter can be started anywhere, but the movement  

orders will not work until the transmitter is inside the working zone. 

 

3.- Range Limiter at startup and operation: The transmitter in order to work must be inside the  

working zone always. 

 

4.- Range Limiter only as an output Relay: This functionality makes the transmitter not to show In  
range or Out of range situation in the transmitter itself. It will not mask any order. The information  
will be sent to the receiver in order to process the information as an output relay or a condition to  

the relay table. 

 

 

Содержание PWR III Series

Страница 1: ...OPERATION INSTALLATION MANUAL PWR Series III PUSHBUTTON TRANSMITTERS...

Страница 2: ...3 SYSTEMS WITH 2 MASTER TRANSMTTERS 12 7 FIRST COME FIRST SERVED OPERATION 13 7 1 INTRODUCTION 13 7 2 SYSTEMS WITH 2 TRANSMITTERS 14 8 PITCH CATCH OPERATION 15 8 1 INTRODUCTION 15 8 2 SYSTEMS WITH 2 T...

Страница 3: ...ue le produit T l commande IKUSI Dichiara che il prodotto Radiocomando IKUSI Declara que o produto Radiocomando IKUSI 93 44 EC 99 5 EC Cumple con las Directivas de Consejo Complies with the provisions...

Страница 4: ...two rechargeable batteries The main specifications are as follows The PWRSIII Frequency band 902 0 to 928 0 MHz ERP 1mW Response Time 100 ms Temperature range 4 F to 149 F 20 to 65 C The PWRSIII6 and...

Страница 5: ...thorized personnel Remove the transmission key when the set is not in use On starting each working day check to make sure that the STOP button and other safety measures are working When in doubt press...

Страница 6: ...the batteries may remain in the charger for an unlimited period of time The capacity of the batteries decreases with use Their life span is estimated to be 500 recharging cycles but this depends larg...

Страница 7: ...on the same runway do not hit it Check the power supply voltage and turn off the mains switch Remember that the receiver has several voltage powered circuits Even when the power has been cut off ther...

Страница 8: ...s diagram which is supplied with the set This diagram receiver outputs The STOP relays KSTOP1 and KSTOP2 are in series and must be connected to the main contactor coil circuit The K2 START and K12 rel...

Страница 9: ...in the case of the channels being signal free Blinks ON when there is a RF signal on the channels DATA OFF when there is not another TM70 system active in the area Blinks ON in the opposite case ID O...

Страница 10: ...ansmitter s identification code Now the STOP relays KSTOP1 and KSTOP2 will be activated The K2 START and K12 relays are activated when the start button is pushed in Press on any of the transmitter s m...

Страница 11: ...ransmitter s command buttons are pressed the corresponding motion will be activated To be able to start up the transmitter all the command controls associated with active motion must be in the neutral...

Страница 12: ...transmitters in Master Master systems first release their receiver cranes otherwise the access to the selected receiver or receivers will be blocked for other transmitters even in the case that the eq...

Страница 13: ...sly The receiver will then shut down and wait ready to accept transmission from any of the two transmitters Next operator holding the master transmitter must then start his own crane select the mode h...

Страница 14: ...f the two transmitters Next operator holding the master I transmitter must then start his own crane select the mode he wants to work in 2 to work with the receiver crane 2 or 1 2 to work in tandem wit...

Страница 15: ...es the ID code every time the receiver is switched off and hence it starts searching for IDs defined in the EEPROM ID code list The first valid ID code found is selected and locked on to it until the...

Страница 16: ...smit in two different radio channels Once the receiver is switched off by any of the transmitters after the liberation time defined in the EEPROM the receiver starts scanning for IDs and radio channel...

Страница 17: ...e exactly as the First come First served mode of operation In the event of pressing the STOP pushbutton the other transmitter is switched on and the START order is being pressed the second transmitter...

Страница 18: ...crane must be pressing the START button The receiver will free the ID code and will SCAN new ID codes and new channels if in the lapse of time of a passive STOP it encounters the new ID it will keep o...

Страница 19: ...transmitters LA70 installed either in fixed positions or on the controlled crane oriented in such a way that it covers the targeted working zone In these cases the transmitters of the remote control s...

Страница 20: ...o zero This is to make movements start in first speed If the remote control is provided with a Display whenever the transmitter is out of range the message Out of Range will be displayed The remote co...

Страница 21: ...direction In this way the working area covered by a transmitter is similar in shape to an ellipse whose dimensions depend on the height of the bridge over the ground Approximately the diagonals of the...

Страница 22: ...to connect the earth cable Use flame resistant cables for the connections Find a suitable place for the installation of the infrared transmitter away from elements which could generate intense electr...

Страница 23: ...aves in the selector In this case the code emitted corresponds with the selector in the master transmitter The communication connection between transmitters must be done with shielded wires 9 5 TECHNI...

Страница 24: ...t on the crane Periodically check the condition of the transmitter rubber seals Change these over if they show signs of deterioration to ensure they remain watertight Clean the battery contacts 10 2 F...

Страница 25: ...tion in SCANNING mode The receiver is not receiving RF signals DATA Is receiving the correct data from a PWRSIII Signal received is not correct ID ID Code OK ID not recognized There are also two LEDs...

Страница 26: ...old transmitter or With the replacement transmitter off remove its EEPROM module as described above and insert the EEPROM module containing system receiver module 2 Insert a charged battery turn on t...

Страница 27: ...4 K2 START RL1 9 RL 1 10 START MOMENTARY 3 K12 HORN RL1 11 RL 1 13 HORN 12 WIRE CONTROL POWER 5 ALL CONTROL CONTACTS DRY IF CONTROL POWER NOT AVAILABLE CONNECT WITH WIRE 1 K3 RL2 RL 2 9 12 HOIST UP 1S...

Страница 28: ...ART MOMENTARY 3 RL1 K12 HORN RL1 11 13 HORN 12 WIRE 5 CONTROL POWER ALL CONTROL CONTACTS DRY IF CONTROL POWER NOT AVAILABLE CONNECT WITH WIRE 1 K3 RL2 RL2 9 12 HOIST UP 1ST SPEED 9 K5 RL2 10 HOIST DOW...

Страница 29: ...IRE 5 ALL CONTROL CONTACTS DRY IF CONTROL POWER NOT AVAILABLE CONNECT WITH WIRE 1 K3 HOIST UP RL2 9 RL2 12 1ST SPEED 9 K5 RL2 10 HOIST DOWN 1ST SPEED 10 K4 RL2 HOIST 11 2ND SPEED 11 K6 RL2 RL2 TROLLEY...

Отзывы: