deutsch
english
39
fr
ançais
38
PCU LED N
2
38
39
10. Monitoring
Explanation of the parametric representation in the final screen in the user level
Presentation Meaning
216
Sequence number (number of exposure jobs)
01/01/2000 Date
01:17:35
Time
040
LED – intensity of the upper panel in %
040
LED – intensity of the lower panel in %
0800
Exposure time [place 1 and 2: minutes; place 3 and 4: seconds]
1
Vacuum ON [1 – ON; 0 – OFF]
0
Nitrogen OFF [1 – ON; 0 – OFF]
The different process parameters are recorded by means of the sensors used in the
PCU LED N
2
. These are shown in the final screen in the user level.
Code
Defect
Cause
Troubleshooting
02
Pump cannot draw
any vacuum
Cutout after 150
seconds
Cover gasket for
exposure chamber
leaky
Replacement
of the lid sealing
Hoses of the vac-
uum system leaky
Replacement
of the hoses
Vacuum pump
defective
Exchange of the
vacuum pump
03
Lid is opened
LED do not work
Lid not closed
Close lid
Lid control (micro
switch) defective
Exchange lid control
(micro switch)
LED defective
Exchange
of the LED
04
No nitrogen flow
Nitrogen valve at
the gas cylinder not
opened. Warning:
The device is only o
be operated with a
maximum pressure
of 5 bar (70 psi)
Open nitrogen valve
gas cylinder not
opened
05
run time of
program=0
no run time of
program was set
set a run time > 0
06
LED error in
program LEDTest
LED defective
LED has to be changed
by trained personnel
Further
Device does not
show any function
Network connection
not correct
Control network
connection
Main switch off
Switch on
main switch
Main switch
defective
Exchange
main switch
11. Troubleshooting plan
Code
Defect
Cause
Troubleshooting
00
Accurate work flow
Not applicable
Not applicable
01
Pump is running
during the expo-
sure process
Cover gasket of
exposure chamber
leaky
Replacement
of the lid sealing
Hoses of the vac-
uum system leaky
Replacement
of the hoses
Breakdown of the error codes in the final screen in the user level
Code
Status
Background display
00
Accurate work flow
Green
01
Pump runs during the exposure process
Red
02
Pump cannot draw any vacuum
Red
03
Lid opened
Red
04
No nitrogen flow
Red
05
Run time of program = 0
Red
06
LED error in program LEDTest
Red