TECHNICAL SPECIFICATION OF PRODUCT 

1.1

 

FUNCTION DESCRIPTION 

Thanks to their construction and number of variants, the OKCE 100, 125 NTR series  storage tanks enable 
economic  preparation  of  hot  service  water  (HSW)  by  means  of  various  power  sources.  Their  nominal 
performance  provides  sufficient  amount  of  hot  water  for  flat  units,  premises,  restaurants,  and  similar 
establishments.  For  HSW  reheat,  electricity,  various  types  of  central  heating  boilers,  recoverable  energy 
sources (heat pumps, solar collectors) and combination of those can be chosen. 

Service water heating via thermal energy through heat exchanger 

Closing valves of the heat exchanger must be opened which ensures heating water flow from the hot water 
heating system.  Together with a closing valve, it is recommended to install an air outlet valve at the inlet to 
the heat exchanger in order to bleed the heat exchanger as needed, in particular before the beginning of 
the heating season. The time of heating using the heat exchanger depends on the temperature and flow of 
water in the hot water heating system. 

 

1.2

 

PRODUCT DESCRIPTION 

The storage tank vessel is welded from a steel sheet; the exchangers from a steel tube and, as a unit, it is 
entirely  coated  with  hot  water  resistant  enamel.  A  flange  is  welded  onto  the  upper  bottom  of  the 
receptacle with a flange lid screwed to it. A sealing ring is inserted between the flange lid and the flange. 

Thermowells  for  placing  a  heating  element  and  sensors  of  regulation  thermostat  and  safety  fuse  are 
located in the flange lid. Electric wiring is placed underneath the plastic removable cover. The temperature 
of water can be set using the thermostat. 

For additional corrosion protection a magnesium anode is mounted in the upper part of the storage tank to 
adjust the electric potential inside the tank, reducing the risk of corrosion. The storage tanks have outlets of 
hot and cold water and a circulation opening welded to them. The tank is insulated with polyurethane foam 
of  40  -  65  mm  thickness.  The  storage  tank  shell  consists  of  a  steel,  powder-paint  coated,  sheet;  the 
connecting  parts  are  metal  coated.  The  entire  storage  tank  stands  on  three  rectification  screws  with  a 
possibility of levelling floor unevenness within the range of 10 mm. The storage tank is to be placed on the 
ground. The tank is tested with pressure of 0.9 MPa, heat exchangers with 1.5 MPa. 

The NTR version has a heat exchanger located in the bottom part of the storage tank and one heating water 
source is used for heating.

 

Содержание OKCE 100 NTR

Страница 1: ...LLATION MANUAL STATIONARY STORAGE TANKS OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou tel 420 326 370 990 fax 420 326 370 980 e...

Страница 2: ...TURE 8 2 4 PRESSURE LOSSES 9 2 5 CONNECTION OF STORAGE TANK TO HOT WATER HEATING SYSTEM 10 2 6 EXAMPLES OF STORAGE TANKS CONNECTION 10 2 7 PUTTING INTO OPERATION 13 2 8 STORAGE TANK CLEANING AND ANODE...

Страница 3: ...ant Ltd would like to thank you for your decision to use a product of our brand With this guide we will introduce you to the use construction maintenance and other information on electrical storage ta...

Страница 4: ...exchangers from a steel tube and as a unit it is entirely coated with hot water resistant enamel A flange is welded onto the upper bottom of the receptacle with a flange lid screwed to it A sealing r...

Страница 5: ...524 E 182 182 F 622 752 L 522 622 Type OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW 1 3 DESIGN AND GENERAL DIMENSIONS OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Figure 1 1 vn j 3 4 vnit n 3 4 vn j 1 2 vnit n...

Страница 6: ...MPERATURE OF HSW C 80 LOWER EXCHANGER HEAT DELIVERY SURFACE m2 1 1 45 BOTTOM EXCHANGER OUTPUT AT RATING WATER TEMPERATURE OF 80 C AND FLOW 720 l h kW 24 32 PERMANENT OUTPUT HSW l h 610 990 TIME OF HEA...

Страница 7: ...e recommend that any of the common decalcifying devices was installed with the appliance or that the thermostat was set to the minimum operating temperature of 60 C setting to position 60 For proper o...

Страница 8: ...op valves can be put between the storage tank and the safety valve During the assembly follow the guide provided by the safety equipment manufacturer It is necessary to check the safety valve each tim...

Страница 9: ...th a discharge valve mounted on the cold service water inlet to the storage tank for potential disassembly or repair When assembling the security equipment follow the standards SAFETY VALVE STARTING P...

Страница 10: ...ing the heat exchanger depends on the temperature and flow of water in the hot water heating system A storage tank is made in universal design depending on the need of connecting the closing valves to...

Страница 11: ...re with a drain valve Each individually lockable storage tank must be at the cold water inlet provided with a stop gate test cock safety valve with a reverse flap and a pressure gauge An example of a...

Страница 12: ...12 Figure 4...

Страница 13: ...closed h When heating the water with thermal energy from a hot water heating system turn off the electricity and open the valves at the inlet and outlet of heating water or bleed the exchanger i When...

Страница 14: ...mostat and thermal fuse Magnesium anode control button for the thermostat Control lights with wires capillary thermometer set of M12 or M10 bolts Heating element When ordering spare parts give part na...

Страница 15: ...EIR CAUSES DEFECT CONTROL LIGHT FAILURE Water in the tank is cold Is on Heating element failure Water in the tank is not warm enough is on Failure of one of the heating coils in the element Water in t...

Страница 16: ...have a combination faucet Before filling the storage tank with water for the first time it is recommended to fasten the flange connection nuts of the tank It is not allowed to handle the thermostat as...

Страница 17: ...livered The service fee was paid pursuant to Act No 477 2001 Coll as amended at EKO KOM a s The client number of the company is F06020274 Take the water boiler packages to a waste disposal place deter...

Отзывы: