Do not try to repair the failure yourselves. Seek either expert or service help. It does not take 
much  for  an  expert  to  remove  the  defect.  When making  a  repair  appointment,  report  the 
type and serial number you find on the performance plate of your storage tank. 

4

 

IMPORTANT NOTICES   

 

 

4.1

 

INSTALLATION REGULATIONS 

 

Without  a  confirmation  of  performed  electrical  installation  issued  by  an  authorised 
company, the warranty certificate shall be void. 

The Mg anode has to be checked regularly and exchanged, if needed. 

No stop valves can be put between the storage tank and the safety valve. 

If the overpressure in the water main exceeds 0.48 MPa, a pressure control valve must be 
mounted before the safety valve. 

All hot water outputs must have a combination faucet. 

Before filling the storage tank with water for the first time, it is recommended to fasten the 
flange connection nuts of the tank. 

It is not allowed to handle the thermostat, aside from temperature resetting with a control 
button. 

All  electric  installation  handling,  adjustment  and  replacement  of  the  regulation  elements 
shall only be performed by an authorised service company. 

The  thermal  fuse  must  not  be  turned  off!  In  case  of  thermostat  defect,  the  thermal  fuse 
interrupts  electric  power  input  to  the  heating  element  if  the  water  temperature  in  the 
storage tank exceeds 95°C. 

As an exception, the thermal fuse may  also switch off due to water overheating caused by 
overheating the hot water heating system boiler. 

We recommend you operate the storage tank with one type of energy. 

 

Both  the  electric  and  water  installation  must  follow  and  meet  the  requirements  and 
regulations relevant in the country of use! 

 

 

 

 

Содержание OKCE 100 NTR

Страница 1: ...LLATION MANUAL STATIONARY STORAGE TANKS OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou tel 420 326 370 990 fax 420 326 370 980 e...

Страница 2: ...TURE 8 2 4 PRESSURE LOSSES 9 2 5 CONNECTION OF STORAGE TANK TO HOT WATER HEATING SYSTEM 10 2 6 EXAMPLES OF STORAGE TANKS CONNECTION 10 2 7 PUTTING INTO OPERATION 13 2 8 STORAGE TANK CLEANING AND ANODE...

Страница 3: ...ant Ltd would like to thank you for your decision to use a product of our brand With this guide we will introduce you to the use construction maintenance and other information on electrical storage ta...

Страница 4: ...exchangers from a steel tube and as a unit it is entirely coated with hot water resistant enamel A flange is welded onto the upper bottom of the receptacle with a flange lid screwed to it A sealing r...

Страница 5: ...524 E 182 182 F 622 752 L 522 622 Type OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW 1 3 DESIGN AND GENERAL DIMENSIONS OKCE 100 NTR 2 2 kW OKCE 125 NTR 2 2 kW Figure 1 1 vn j 3 4 vnit n 3 4 vn j 1 2 vnit n...

Страница 6: ...MPERATURE OF HSW C 80 LOWER EXCHANGER HEAT DELIVERY SURFACE m2 1 1 45 BOTTOM EXCHANGER OUTPUT AT RATING WATER TEMPERATURE OF 80 C AND FLOW 720 l h kW 24 32 PERMANENT OUTPUT HSW l h 610 990 TIME OF HEA...

Страница 7: ...e recommend that any of the common decalcifying devices was installed with the appliance or that the thermostat was set to the minimum operating temperature of 60 C setting to position 60 For proper o...

Страница 8: ...op valves can be put between the storage tank and the safety valve During the assembly follow the guide provided by the safety equipment manufacturer It is necessary to check the safety valve each tim...

Страница 9: ...th a discharge valve mounted on the cold service water inlet to the storage tank for potential disassembly or repair When assembling the security equipment follow the standards SAFETY VALVE STARTING P...

Страница 10: ...ing the heat exchanger depends on the temperature and flow of water in the hot water heating system A storage tank is made in universal design depending on the need of connecting the closing valves to...

Страница 11: ...re with a drain valve Each individually lockable storage tank must be at the cold water inlet provided with a stop gate test cock safety valve with a reverse flap and a pressure gauge An example of a...

Страница 12: ...12 Figure 4...

Страница 13: ...closed h When heating the water with thermal energy from a hot water heating system turn off the electricity and open the valves at the inlet and outlet of heating water or bleed the exchanger i When...

Страница 14: ...mostat and thermal fuse Magnesium anode control button for the thermostat Control lights with wires capillary thermometer set of M12 or M10 bolts Heating element When ordering spare parts give part na...

Страница 15: ...EIR CAUSES DEFECT CONTROL LIGHT FAILURE Water in the tank is cold Is on Heating element failure Water in the tank is not warm enough is on Failure of one of the heating coils in the element Water in t...

Страница 16: ...have a combination faucet Before filling the storage tank with water for the first time it is recommended to fasten the flange connection nuts of the tank It is not allowed to handle the thermostat as...

Страница 17: ...livered The service fee was paid pursuant to Act No 477 2001 Coll as amended at EKO KOM a s The client number of the company is F06020274 Take the water boiler packages to a waste disposal place deter...

Отзывы: