OPERATION AND FITTING INSTRUCTIONS
2.1
OPERATING CONDITIONS
The tank shall only be used in accordance with the conditions specified on the power plate
and in instructions for electric wiring. Besides legally acknowledged national regulations and
standards, also conditions for connection defined in local electric and water works have to
be adhered to, as well as the installation and operation manual.
The temperature at the place of storage tank installation must be higher than +2°C; and the
room must not freeze. The appliance has to be mounted at a convenient place; it means that
the appliance must be easily available for potential necessary maintenance, repair or
replacement, as the case may be.
If water is strongly calcareous we recommend that any of the common decalcifying devices
was installed with the appliance, or that the thermostat was set to the minimum operating
temperature of 60°C (setting to position “60“). For proper operation, drinkable water of
adequate quality shall be used. To avoid potential sediments we recommend that the device
was installed together with a water filter.
2.2
ELECTRIC INSTALLATION
2.2.1
WIRING FOR: OKCE 100 S/2,2 KW, OKCE 125 S/2,2 KW
The electric wiring scheme is attached to the storage tank on the side of the electric installation guard.
Connection, repairs, and wiring inspections may only be implemented by a company (person) authorised to
such activity.
The storage tank is connected to the 230 V/50 Hz electric network using a fixed moving conductor with a
switch that turns off all network poles and the circuit breaker (protector). The degree of protection of
electric parts of the storage tank is IP 44.
Wiring scheme: