26
-
F06
Parameters
(continued)
H01TCC
-
P01TCC parameter hysteresis
2
10
4°C
P02TCC
-
required temperature, final el. heating
1
65
60°C
H02PV
-
P02 parameter hysteresis
2
20
10°C
P03
-
defrost start
-
15
10
-
8°C
P04
-
defrost finish
0
25
16°C
P05
-
safe temperature
70
80
70°C
P06
-
Anti
-L
egionella disinfection temperature
60
69
65°C
P07
-
min evaporator temperature for final el.
heating activation
-
15
20
-
5°C
P07
-
setting
ON
OFF
ON
P08
-
min water temperature for final el. heating
activation
1
40
30°C
P08
-
setting
ON
OFF
ON
P09
-
air temperature for defrost
0
15
10°C
P10
-
minimum air temperature
-
10
10
-
5°C
H10
-
P10 parameter hysteresis
2
10
5°C
T01
-
delay before compressor startup
1
20
2 min
T02
-
min running time before defrost
1
10
1 min
T03
-
max defrost time
2
15
8 min
T04
-
compressor startup delay after defrost
1
10
1 min
T05
-
max compressor runtime
6
15
10 h
T06
-
defrost start time delay
30
360
60 s
T07
-
startup delay after low pressure error
2
20
10 min
T08
-
time interval between defrost cycles
10
120
40 min
T09
-
prodleva před vyhlášením LAT
2
20
5 min
T10
-
min defrost time
2
10
4 min
F07
INFO
List of control parameters
F08
Level
Installation technician
0022
Manufacturer
****
F09
Output test
CO
-
contact N.O., compressor
RE -
contact N.O., final el. heating
VE
-
contact N.O., fan
V4V
-
contact N.O., 4
-
way valve
F10
Errors
Elist
-
list of error messages
Ereset
-
deletion of error messages
F11
Reset
Restoring default settings
F12
System
Compressor runtime
hours