25
-
5.8
CHANGING THE MODE
ECO is set as the default mode for the operation
of the device. If at any time the user wants to edit
the operation mode they can proceed as follows:
Unlock the keypad and hold the
MENU
key down for
3 seconds
. Use the
COMP
▲
and
E-HEATER
▼
keys to
browse the menu and select F03 to enter the submenu
and select the operation mode.
Note:
To change the operating mode, you do not need to restart the appliance.
PROPER OPERATION TEST
To check whether your device works properly, run it and wait about 20
-
30 minutes and then check
the following:
•
The air
temperature at the evaporator outlet should be lower by 3
-
4 °C compared to the air
temperature at the inlet.
DESCRIPTION OF PARAM
ETERS
Code
Type
Description
Min
Max
Setting
F01
Language
Portuguese
English
French
German
Italian
Spanish
Czech
English
F02
Clock
Date and time
F03
Mode
Eco mode
Boost
Auto
Eco
F04
Holiday
Holiday mode
1
99
0
F05
Disinfection
Disinfection function inactive
Disinfection function active once a week
Disinfection function active once a month
---
---
Monthly
F06
Parameters
P01
-
required temperature, compressor
5
55
53°C
H01
-
P01 parameter hysteresis
2
10
4°C
P02
-
required temperature, final el. heating
1
60
53°C
H02
-
P02 parameter hysteresis
2
10
4°C
P01TCC
-
required temperature, compressor
5
55
55°C