22
-
ver
12/10/12
10:25
Ver 0.M.X.X
45 ºC
12/10/12
10:25
ON
ON
ECO
45 ºC
12/10/12
10:25
ECO
AUTO
BOOST
Then you can start the device by following these instructions:
Note 1:
LED on the display indicates the status of the appliance. If it blinks, it means that the device has no
operating instructions set up. If the LED is lit and not flashing, the system works according to the given
instructions.
Note 2:
Restart the unit by switching off and repeated switching on by pressing the
ON/OFF
button.
5.5
OPERATING MODES
AQUA HP is programmed to run in three operating modes
-
ECO, AUTO and BOOST that are summarized
in the following table:
User can change the operating mode at will, all they need is to simultaneously press the
MENU + OK/LOCK
keys for 3 seconds. Upon entry, use the
COMP
▲
and
E-HEATER
▼
keys to move in the menu and submenus.
To confirm the values/parameters press the
OK/LOCK
key
.
To exit the menu, press the
CANCEL
key.
5.5.1
ECO Mode
In the ECO operation mode, the device operates only as a heat pump heating water in a hot water tank.
It is thus possible to achieve greater efficiency and savings for user.
Every time the user deems it necessary, they can turn on a supporting heating element in this mode manually
by pressing the (E
-
HEATER) key. This device automatically changes the operating mode to BOOST
and indicates this status on the display (including the heating element indication). If the heating element
is turned off manually, the appliance returns to the ECO mode.
Mode
Symbol
Function
ECO
Regular mode as heat pump
AUTO
Optimised management of heat pump or electrical heating
element run
BOOST
Run of both the heat pump and the electrical heating element
Controller when turned on
The system is turned off
(OFF)
Press the
ON/OFF
switch
Press the
COMP
key to
start the system
ECO
ECO