24
-
5.5.5
LAT Mode
LAT mode starts automatically at a
low temperature of the input air in order to protect the compressor. When
this mode is activated, the compressor shuts down and only electric heating activates. When the intake air
temperature rises, the device returns to the previously selected mode.
5.6
ADDITIONAL FUNCTIONS
5.6.1
Disinfection Mode
The AQUA HP controller includes a Disinfection (Anti
-
Legionella) function consisting of a water heating cycle
up to 65 °C for a time sufficient to prevent formation of bacteria inside the tank.
The disinfection function can be set automatically or manually. In the automatic mode, user can set
the function to every week or every month. Unless the automatic mode is activated, user must be activated
manually by pressing Disinfect.
At the end of this function, the
system returns to the operating mode
set before the activation
of this function.
5.6.2
Holiday Mode
To activate the
Holiday
function, it is necessary to enter the menu and set the number of days of the holiday
and the appliance automatically enters the
standby
mode and stays there until the last day of the holiday.
The last day of the holiday the appliance activates the
disinfection
function to eliminate any formation of
bacteria that could emerge in the hot water tank during the periods of user's absence.
Once the holiday is over and the disinfection programme terminates, the appliance returns to the selected
mode (ECO, AUTO or BOOST).
Note: If you set the appliance to enter into the holiday mode, but switch it OFF and ON using the ON/OFF
switch, the function will not be active. After returning from a holiday, user must not forget to turn on the
appliance and cancel the entered holiday days (value = 0). If user fails to do so, the appliance returns to the
default mode until the expiration of the specified number of the holiday days.
5.7
MENU
Every time the parameters need to be modified or new ones set during the operation of the device, user
must enter the menu.
To access the menu, it is necessary to press the
MENU
button
for 3 seconds
. Upon the entry, use the
COMP
▲
and
E-HEATER
▼
keys to navigate the menu and submenus. To confirm the values/parameters press
the
OK/LOCK
key
.
To exit the menu, press the
CANCEL
key.
LAT