- 8 -
TROUBLE SHOOTING
TROUBLE
PROBABLE CAUSE
REMEDY
Pump unit will not work.
Dirt on valve seats/worn seals.
Replace with new seals.
Pump unit will not produce
Air block
(1) Open the release valve
pressure
and remove oil filler plug.
OR
(2) Pump handle a couple of full
Pump unit feels unsteady
Air block
strokes and close the release
under load.
valve.
OR
Pump unit will not lower
Air block
(3) Replace filler plug.
completely.
Pump unit will not produce
The reservoir could be
To check the oil level – remove
pressure
overfilled or low on
the filler plug. Top up oil to
hydraulic oil level
correct level.
Pump unit feels unsteady
The pump cup seal could
Replace the cup seal with a
under load
be worn out
new one.
Pump unit will not lower
Air block
Release air by removing filler
completely
plug.