- 7 -
CARE AND MAINTENANCE
1. When the body repair kit is not in use, the pump
unit should be stored with the release valve open.
2. To check oil level, place the pump unit in an
upright position. As indicated on the diagram
opposite. Remove the dip stick and the oil level
will be indicated. If required add hydraulic oil
until it is level with the full mark on the stem. YOUR
JACK WAS FILLED AT THE FACTORY WITH HIGH
GRADE HYDRAULIC OIL. ONLY USE APPROVED
OIL*.
3. After extensive use, the oil supply should be
replaced to ensure longer equipment life. To
drain, remove the dip stick and open release
valve. Ensure that no dirt gets into the system.
Refill with approved jack oil, as paragraph 2.
*We recommend
Shell Telus 22.