INSTALLING THE UNIT
- fIRST THINGS fIRST -
Cut the fastener
gypsum Board
Wood Panel
Wall Stud
1) mouNtiNG tHe uNit oN tHe wALL
• Undo the fastener securing the wall bracket and base at the back of the unit with cutting pliers.
• Attach the bracket to the wall with the five screws supplied with the unit.
If the wall includes wall studs covered with gypsum
board, we recommend installing a wooden panel
screwed to the wall studs beforehand for more
stability.
Suggest
ed dista
nce from t
he floor
Stand
ard insta
llation : 5
0” (125 c
m)
Installat
ion with l
ower tank
Tank : 4
0” (100 c
m)
Unit : 6
5” (165 c
m)
INSTALLING THE UNIT
-
STEP SEQUENCE -
wHere wiLL You iNstALL tHe uNit?
We recommend installing the system on the lowest level of the building to avoid having to work against
gravity. The basement is generally the most ideal location, near the building’s main drainpipe. A cold water
pipe must also be available and connected to the unit. Vents are necessary if the unit is further then 6’
(2m) away from the main drain. If there is no basement, the garage or a storage room will do.
miNimum DimeNsioNs AND spACiNG
It is important to install the unit in a location where it will be easily accessible for maintenance and to effec-
tively evacuate the waste. The following is the minimum spacing recommended:
* For models with a standard tank, the bottom of the P-Trap can be installed at 15” (38cm) from the floor.
However,
we recommend 26” (66 cm), if possible, so that a pail can be placed under the unit, if need be,
when removing the P-Trap.