DV1A150 / DF1A150
DV2A310 / DF2A310 / DV2A31 / DF2A31
DV2A32 / DF2A32
DVDC40 / DFDC40
TiTre
TiTre
ELECTRICAL POWER SUPPLy
DiAGrAms oF tHe AppropriAte CoNNeCtioNs For Your moDeL
DV1A150 : 15-amp. circuit / 120v
DF1A150 : 16-amp. circuit / 240v
DV2A310 & DV2A31 : 20-amp. circuit / 120v
DF2A310 & DF2A31 : 16-amp. circuit / 240v
electrical Panel
electrical Panel
DV2A32 : 20-amp. circuit / 120v
DF2A32 : 16-amp. circuit / 240v
24-volt wires (supplied with the unit)
electrical Panel
DVDC40 : 15-amp. circuit / 120v
DFDC40 : 16-amp. circuit / 240v
24-volt wires (supplied with the unit)
electrical Panel
If you experience voltage surge problems on your electrical circuit in spite of adequate connections,
a high magnetic circuit breaker can be installed on your electrical panel. Contact an electrician for
more information.
GrouNDiNG iNstruCtioNs
These units must be grounded. If it should malfunction or breakdown, grounding provides a path of least
resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord
having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate
outlet that is properly installed and grounded in accordance with all local codes and ordinances.
wArNiNG
- Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check
with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded.
Do Not moDiFY tHe pLuG proViDeD witH tHe uNits -
iF it Does Not Fit tHe outLet, HAVe A proper outLet iNstALLeD
BY A QuALiFieD eLeCtriCiAN.
These units are for use on a nominal 120V circuit and has a grounding attachment plug that looks like the one illus-
trated below. make sure that the electrical cord is connected to an outlet having the same configuration as the plug.
No ADAptor sHouLD Be useD witH tHis AppLiANCe.
*Illustration of a north-americain electrical outlet
grounded
Outlet
grounded pin
ELECTRICAL POWER SUPPLy