INSTALLING THE UNIT
INSTALLING THE UNIT
-
-
STEP SEQUENCE -
STEP SEQUENCE -
Clamp
2) CONNECT THE DUST AND WATER INLETS
• Connect the building’s cold water supply to the unit’s water inlet.
• Connect the dust inlet (transparent tubes)
to the unit securing it with a clamp.
* N.B. The tubes have been pressure pre-
assembled.
Do not use glue
.
• Connect the suction hose to the unit’s dust inlet, secur-
ing it with a clamp.
Clamp
Practical plug for
maintenance
(When needed, use a
brush to clean the
inside of the tubes)
17
24” (60 cm)
10”
(25 cm)
53” (13
6 cm
)
68” (17
4 cm
)
[ D
V1A150
/DF1A150 = 4
9” (12
3 cm
) ]
[ D
V1A150
/DF1A150 = 64” (16
2 cm
) ]
[ 15” (38 cm) ]
*
24” (60 cm)
10”
(25 cm)
15” (38 cm)
TITRE
TITRE
TITRE
INSTALLING THE UNIT
INSTALLING THE UNIT
- FIRST THINGS FIRST -
- FIRST THINGS FIRST -
We recommend installing the system on the
lowest level of the building
to avoid having to work against
gravity. The basement is generally the most ideal location,
near the building’s main drainpipe
. A cold wa-
ter pipe must also be available and connected to the unit. If there is no basement, the garage or a storage
room will do.
It is important to install the unit in a location where it will be easily accessible for maintenance and to effec-
tively evacuate the waste. The following is the
minimum spacing
required:
WHERE WILL YOU INSTALL THE UNIT?
MINIMUM DIMENSIONS AND SPACING
* For models with a
standard tank
, the bottom of the P-Trap can be installed at 15” (38cm) from the floor.
However,
we recommend 26” (66 cm)
, if possible, so that a pail can be placed under the unit, if need be,
when removing the P-Trap.