70
Transport
en
10. Install switch box.
11. Fit the compressed oxygen cylinder (see chapter 3.3.2 on
5
Transport
Ensure that the closed-circuit breathing apparatus is
transported in an upright position so that the condensate in the
breathing hoses can gather in the drain valve and breathing
bag.
6
Storage
When the closed-circuit breathing apparatus is stored with
fitted CO
2
absorber, the breathing circuit must be closed. The
compressed oxygen cylinder does nove to be installed. The
expiry date of the CO
2
absorber must not be exceeded during
the next use.
Store the closed-circuit breathing apparatus ready for use in a
dark, cool, dry, dirt-free and dust-free place. Avoid exposure to
UV rays and ozone. The closed-circuit breathing apparatus
should be stored upright as far as possible.
7
Disposal
Dräger accepts returned single-use CO
2
absorber cartridges
for a charge. A decision on its subsequent use will be made
when the product is returned. For information please contact
the national sales organisations and Dräger.
Alternatively, the CO
2
absorber can be disposed of as follows:
1. Pack the CO
2
absorber in a bag and seal air-tight.
2. Dispose of the CO
2
absorber in accordance with the rele-
vant regulations.
This closed-circuit breathing apparatus must not be
disposed of as municipal waste. This is indicated by
the adjacent icon.
You can return this product to Dräger free of charge.
For information please contact the national sales or-
ganisations and Dräger.
Batteries and rechargeable batteries must not be
disposed of as municipal waste. This is indicated by
the adjacent icon. Collect and dispose of batteries and
rechargeable batteries at battery collection centres,
in accordance with applicable regulations.
CAUTION
Risk of chemical burns!
The chemicals in the CO
2
absorber react with the
humidity in the atmosphere or water to form a caustic
base. The base causes severe eye damage and skin
irritation, it can also irritate the respiratory system.
Use protective goggles and base-resistant gloves
when working with the CO
2
absorber.
!
Содержание PSS BG 4 RP
Страница 1: ...Dr ger PSS BG 4 RP i ru 4 en Instructions for Use 40...
Страница 2: ......
Страница 3: ...9 2 1 3 4 5 6 7 8 10 11 12 14 16 17 18 19 20 21 13 15 1 2 3 4 5 6 7 1 2 3 4 5 5 7 8 33321851 eps B A 6...
Страница 9: ...9 ru 2 7 2 7 1 Dr ger Dr ger Dr ger Dr ger Dr ger Dr ger i i...
Страница 12: ...12 ru Dr ger FPS 7000 RP Panorama Nova RP 1 2 2 7 4 PCas APECas 1 2 i i...
Страница 20: ...20 ru 4 1 6 5 6 X X1 X2 X X 3 X CO2 X X4 CO2 X X4 X5 1 2 3 Dr ger 4 CO2 4 5 27 5...
Страница 28: ...28 ru 4 5 1 1 3 2 3 3 3 1 15 4 4 5 2 1 2 3 4 1 4 Bodyguard 1 2 3 4 5 6 7 OK 34921851 eps L min 6 5 3 4 7 1 2...
Страница 35: ...35 ru 5 6 CO2 CO2 7 Dr ger CO2 Dr ger CO2 1 CO2 2 CO2 Dr ger Dr ger CO2 CO2...
Страница 38: ...38 ru PC PCas TR...
Страница 74: ......
Страница 75: ......
Страница 76: ......
Страница 77: ......