LAMINATION MODULE
(SCR22PL AND SCR35PL MODELS)
MATRIX REMOVER
AND SLITTER MODULE
MEDIA PATH
ULTRASONIC SENSOR CALIBRATION
22
WARNING:
Before proceeding with the ultrasonic sensor
calibration, turn “OFF” the module that needs to be calibrated
(lamination or matrix&slitter modules).
LAMINATION MODULE
1. Raise up the tension arm up to the
desired position (generally it is in the
middle of the range). In that position,
the system will reach the maximum
unwinding’s speed. The longer your
label will be, the lower tension arm
position requires to be set.
2. Holding the tension arm idle at the
desired position, using a paper clip,
keep pushed the button into the small
hole until the yellow led will flash and
the unit will emit an acoustic signal.
3. The ultrasonic sensor has been
calibrated and ready to be operative.
MATRIX REMOVER AND SLITTER
MODULE
1. Raise up the tension arm up to the
desired position (generally it is in the
middle of the range). That point will
determinate the tension arm working
range from the bottom position. The
longer your label will be, the lower
tension arm position requires to be set.
2. Holding the tension arm idle at the
desired position, using a paper clip,
keep pushed the button into the small
hole until the yellow led will have
flashed 3 times.
3. The ultrasonic sensor has been
calibrated and ready to be operative.