background image

Manual Code 2600103

 

 

DOMIX 35 – Rev.7 - 02.09.2014                                                                                                              

10/30 

 

2-

 

MANUAL INTERPRETATION 

 
All parts of the text that are important to the safety of people and objects are written in 
bold. The purpose of this manual is to provide the user, the installer and the maintenance 
technician with all the technical information required for the installation, use and ordinary 
maintenance operations to guarantee a long machine life. 
Should  any  spare  parts  be  required,  only  original  components  should  be  used.  Requests 
for  SPARE  PARTS  or  INFORMATION  relating  to  the  unit  must  be  made  to  the  distributor  or 
the  nearest  technical  assistance  centre,  quoting  the  MODEL  and  MACHINE  SERIAL 
NUMBER shown on the technical characteristics label. 
 
 

 

The meaning of this symbol (used both on the machine and in this manual) is: 
Danger, electric shock risk. 

 
 

The meaning of this symbol (used both on the machine and in this manual) is: 
Caution, please refer to attached documentation. 

 
 

The meaning of this symbol (used both on the machine and in this manual) is: 
Operation prohibited. 

 

 
 

3-

 

PRELIMINARY INSPECTION 

 

Inspect the unit as soon as it has been received. 
Carefully check that all the components are on the packing list or invoice. 
Promptly advise of any damage caused during transportation and send a claim to the 
courier without delay. 
VERY IMPORTANT: the manufacturer shall not be held liable for whatever damage to the 
unit during transportation. 

 
 

4-

 

BASIC RULES OF SAFETY 

 

The use of the device is prohibited for children and persons with disabilities who are 
not assisted. 
 
It is prohibited to touch the device if you are barefoot and with body parts wet or 
damp. 
 
Any cleaning operation is prohibited before it has disconnected the unit from the 
mains. 
 
Not modify the safety devices or setting without the manufacturer permission. 
 
It is prohibited detach, twist the wires even if it is disconnected from the mains. 

Содержание DOMIX 35

Страница 1: ...MIX 35 DOMIX 35 DOMIX 35 DOMIX 35 Water Doser Mixer USER S INSTRUCTION MANUAL CODE 2600103 CODE 2600103 CODE 2600103 CODE 2600103 Rev 02 Rev 02 Rev 02 Rev 02 18 01 2011 18 01 2011 18 01 2011 18 01 201...

Страница 2: ......

Страница 3: ...Manual Code 2600103 DOMIX 35 Rev 7 02 09 2014 3 30 Fig 1 Descrizione esterna della macchina Machine overview Description ext rieure de l appareil...

Страница 4: ...NTO IDRAULICO HYDRAULIC CONNECTION EXAMPLES SCHEMAS DES RACCORDEMENTS HYDRAULIQUES HYDRAULISCHE SYSTEME EJEMPLOS DE CONEXION HIDRAULICA FIG 4 FIG 5 FIG 6 Boiler Caldera Rete Cold water mains R seau Ka...

Страница 5: ...Manual Code 2600103 DOMIX 35 Rev 7 02 09 2014 5 30 Fig 3 Schema Elettrico Wiring Diagram Sch ma lectrique...

Страница 6: ...Manual Code 2600103 DOMIX 35 Rev 7 02 09 2014 6 30 Fig 4 Dimensioni Dimensions Dimensions...

Страница 7: ...TION 14 8 ERRORS 15 8 1 LITRES COUNTER ERROR 15 8 2 PROBE ERROR 15 8 3 POWER FAIL 15 8 4 SOLENOID VALVE LEAKING 16 9 MAINTENANCE INSTRUCTIONS 16 10 USELESS DEVICE DISPOSAL 17 11 CERTIFICATIONS 17 12 T...

Страница 8: ...25 8 1 PAS D IMPULSION DU COMPTE LITRES 25 8 2 SONDE EN PANNE 25 8 3 CHUTE DE TENSION 25 9 ENTRETIEN 26 10 RECYCLAGE DES APPAREILS QUI NE SONT PLUS UTILISES 27 11 CERTIFICATIONS 27 12 DEFAUTS DE FONCT...

Страница 9: ...L min 88 lb min Internal probe Thermo resistor PT1000 typeA Supply fuse 250 V T250 mA retarded 208 240 V 250 V T630 mA retarded 110 127 V Pump control fuse 250 V F6 3 A Protection Rating IP 42 1 1 DES...

Страница 10: ...is symbol used both on the machine and in this manual is Caution please refer to attached documentation The meaning of this symbol used both on the machine and in this manual is Operation prohibited 3...

Страница 11: ...s to be collected by courier Any repairs or modifications must be carried out solely by the manufacturer or its authorised distributors or following explicit authorisation by the manufacturer or its a...

Страница 12: ...pm it is necessary to employ an ion exchange water softener This unit must be calibrated so as to maintain a residual hardness ranging between 5 and 10 French degrees 50 100 ppm The use of electronic...

Страница 13: ...use of such a pump is necessary when one of the two inlet pressures in less than 1 bar for example when using unpressurized water heaters or refrigerators NOTICE in the case of water chiller equipped...

Страница 14: ...TensFAI At the first pressure of the STOP C key the machine shows the discharged quantity till it was stopped the operator may now cancel the discharge by pressing again the STOP C key or to resume b...

Страница 15: ...pper display is shown the delivered quantity By pressing the START key the delivery continues by pressing the STOP C the machine turns into idle state For relative troubleshooting see paragraph 12 8 2...

Страница 16: ...external filters 3 The frequency depends on the impurities present in the pipes To clean the external surface of the doser mixer use a soft sponge and water or a neutral detergent for more resistant...

Страница 17: ...nd reused The European Directory 2002 96 CE about electric and electronic devices disposal RAEE prescribes the separate collection of the electric and electronic devices respect to the mixed urban dis...

Страница 18: ...r coming from the chiller Disconnect the power check and if necessary replace the fuse for the pump command relay Liter counter damaged Replace the liter counter Pr E in the temperature display Intern...

Страница 19: ...b Pr cision dans le dosage 1 d charge min 5L D bit eau 1 bar et 20 C 18 L min 55 lb min D bit eau 5 bars et 20 C 40 L min 121 lb min Sonde int rieure Thermo r sistance PT1000 Classe A Fusible pour l a...

Страница 20: ...dans ce manuel signifie Op ration non autoris e 3 INSPECTION PRELIMINAIRE Contr ler l appareil imm diatement apr s la r ception Contr ler tous les composants figurant sur la facture signaler les domma...

Страница 21: ...agr s ou apr s leur accord expr s Les produits qui ont t utilis s d une fa on incorrecte soumis une d t rioration intentionnelle ou involontaire ou une surtension sont exclus de la garantie Le fabrica...

Страница 22: ...et appareil doit tre r gl de mani re laisser une duret r siduelle comprise entre 5 et 10 50 100 ppm L utilisation d adoucisseurs lectroniques est d conseill e car leur efficacit doit encore tre prouv...

Страница 23: ...ux pressions en entr e est inf rieure 1 bar comme par exemple dans le cas de chauffe eau ou de refroidisseurs accumulation non pressuris s ATTENTION dans le cas d un refroidisseur autoclave cuve avec...

Страница 24: ...nt avec la machine teinte que pendant les op rations de dosage les donn es introduites ne sont pas perdues Ainsi lorsque le courant revient il suffit de repousser la touche START pour que le d verseme...

Страница 25: ...areil passe en veille et la quantit d eau d vers e est affich e sur la partie sup rieure de l cran En appuyant sur la touche START le d versement reprend tandis qu avec la touche STOP C l appareil s a...

Страница 26: ...uret s dans les tuyaux Nettoyer l ext rieur de l appareil chaque semaine avec une ponge douce impr gn e d eau et de savon neutre pour les salissures plus tenaces utiliser de l alcool ou du diluant Ne...

Страница 27: ...eur qui peuvent tre recycl s et r utilis s La Directive europ enne 2002 96 CE sur les d chets d appareils lectriques et lectroniques RAEE prescrit la r colte diff renci e des appareils lectriques et l...

Страница 28: ...la commande de la pompe Err L et l eau sort avec un faible d bit du doseur Filtre d entr e obstru Nettoyer le filtre Faible pression en entr e Contr ler la ligne d alimentation en eau Err L et l eau...

Страница 29: ...l Code 2600103 DOMIX 35 Rev 7 02 09 2014 29 30 12 7 55 10 5 50 45 40 15 20 35 30 17 25 13 PEZZI DI RICAMBIO SPARE PARTS PIECES DETACHEES Fig 5 Schema ricambi Spare Parts scheme Sch ma des pi ces d tac...

Страница 30: ...ion et actionneurs prises 3811548 3811547 6 Sonda interna Internal probe Sonde de temp rature interne 3812525 7 Kit interno E V Solenoid valve internal kit Kit interne lectrovanne 4400451 8 Gruppo ele...