Manual Code 2600103
DOMIX 35 – Rev.7 - 02.09.2014
16/30
8.4.
Solenoid valve leaking
L E A K
E. V.
DISPLAY 4
It could happen that the solenoid valve doesn’t close properly with some water leaking. In
this case the following message appears:
“LEAk E.V.”
This kind of error doesn’t lock the
device. The user can operate the machine, but if the problem is not solved the alarm will
appear again.
To cancel the alarm the
[STOP/C]
key must be pressed.
For relative troubleshooting see paragraph 12-.
In the installer parameters it is also possible to deactivate the control.
9-
MAINTENANCE INSTRUCTIONS
•
Perform periodic cleaning of the external filters (3). The frequency depends on the
impurities present in the pipes.
•
To clean the external surface of the doser-mixer, use a soft sponge and water or a
neutral detergent; for more resistant grime, use alcohol or turpentine.
•
No direct jets of water on the device.
•
When switching off the doser-mixer, set always the temperature regulation knob (5)
to its mid position, to allow a minimum number of moves in the mixer valve,
particularly when deliveries at the same temperature are carried out.
•
Clean the internal membrane of solenoid valve regularly (6 months), particularly if
the water contains a high quantity of lime-scale.
•
Check periodically the litre-counter error, using a high precision scale.
The use of non-original spare parts is strictly prohibited.
The code for the spare parts are located in the
Tab. 1