Dover Unified Brands Power Soak POWER PREP UNLIMITED Скачать руководство пользователя страница 6

OM-POWER PREP UNLIMITED

PUMP PARTS LIST

Item

Description

Part No.

1

MOTOR, 3 PHASE

42704

1

MOTOR, 1 PHASE

40983

2

ADAPTER, HOUSING

41687

3

GUARD

41688

4

SEAL, CUP & SPRING ASSEMBLY

41689

5

TRI-CLAMP, 6”

41690

6

PUMP CASING

41691

7

IMPELLER

41692

8

BACK PLATE

41693

9

GASKET

41680

10

RETAINING PIN, IMPELLER

41695

11

STUB SHAFT

41696

12

DEFLECTOR

41697

 

HAZARDOUS VOLTAGE INSIDE. DISCONNECT POWER BEFORE SERVICING. 

SERVICE BY TRAINED PERSONNEL ONLY. 

 

KEEP FINGERS OUT OF PORTS.

 

HOT SURFACES.

PUMP “D” SEAL, CUP & SPRING ASSEMBLY

1.   O-ring Seal  

 

 

            Seal, cup & spring assembly

2.   Place o-ring inside of the seal

3.   Install seal assembly onto stub shaft. Keep notch in cup aligned with the pin on 

the stub shaft.

TYPE “D” SEAL PARTS BREAKDOWN

Note: Seat seal, cup and spring is provided preassembled.

Содержание Unified Brands Power Soak POWER PREP UNLIMITED

Страница 1: ...ng the Power Prep Unlimited and are committed to standing behind our customers and products 100 Should you ever need assistance please contact us directly at the factory by dialing 888 994 7636 or fax 601 371 9732 PRODUCE WASHING CHEMICALS AND ANTIMICROBIALS The produce wash product you select is best if it Requires a minimal wash time ideally two minutes or less Requires no rinsing Is non corrosi...

Страница 2: ...asily accessible by the operator and does not interfere with the faucet Specific part numbers and parts information can be obtained from the factory by calling 888 994 7636 PLUMBING REQUIREMENTS The Power Prep Unlimited unit will require the following plumbing connections 3 4 19mm or 1 2 12 mm hot and cold water supply lines Waste water connection minimum 1 1 2 38mm LEVELING REQUIREMENTS Your unit...

Страница 3: ...Flow Guides Once the partition is in place the flow guides can be installed Start by positioning a notched end of the flow guide adjacent to the hooks of the front rib set Begin bending the flow guide to the shape of the front rib set and allow the notches of the flow guide to engage the hooks of the rear rib set Continue to push the flow guide down against the rib sets until the notched end of th...

Страница 4: ...g product in the Power Prep Since there are two compartments you may be tempted to place a different type of product in each one DO NOT do so you risk cross mixing allergens between different types of product After the necessary time for removing the ice covering the product may be removed by inserting a collection basket Holding the basket as shown angle the basket so its leading edge is aligned ...

Страница 5: ...y more soil and other organic materials Consider the possibility of certain foods imparting strong flavor color or odor It might be better to wash cut cauliflower before washing blueberries to prevent staining and discoloration Wash onions leeks garlic or other strong flavored foods separately or last to prevent imparting taste or odor to other vegetables and fruit Consider washing strawberries or...

Страница 6: ...AINING PIN IMPELLER 41695 11 STUB SHAFT 41696 12 DEFLECTOR 41697 HAZARDOUS VOLTAGE INSIDE DISCONNECT POWER BEFORE SERVICING SERVICE BY TRAINED PERSONNEL ONLY KEEP FINGERS OUT OF PORTS HOT SURFACES PUMP D SEAL CUP SPRING ASSEMBLY 1 O ring Seal Seal cup spring assembly 2 Place o ring inside of the seal 3 Install seal assembly onto stub shaft Keep notch in cup aligned with the pin on the stub shaft T...

Страница 7: ...haft 4 Slide on the impeller and push retainer pin over to one side to hold impeller in place 5 Align the pump casing to the gasket on the face plate Feel behind the pump casing to ensure the housing is seated evenly against the backing plate gasket 6 Twist the pump so that the outlet is facing straight up then install the quick clamp 7 Hold 2 Gaskets into place and install the inlet pipe to the p...

Страница 8: ...POWER PREP RUNNING THE MACHINE WITHOUT WATER IN THE WASH TANK WILL CAUSE DAMAGE THAT IS NOT COVERED BY WARRANTY IMPORTANT TURN OFF THE POWER TO THE UNIT AT THE MAIN BREAKER PRIOR TO PERFORMING THE FOLLOWING TASK Your system requires minimal routine preventive maintenance As such the following should be done on a routine basis to ensure that your system remains reliable DAILY MAINTENANCE Clean the ...

Страница 9: ...n contained in the Operator s Manual for this equipment before it is placed in service If you have any questions related to equipment set up operations or service please call 888 994 7636 In addition please review the sales terms and conditions set forth below IMPORTANT NOTICE WARRANTIES LIMITATIONS ON WARRANTIES AND LIMITATION OF REMEDIES The following Warranties Limitation on Warranties and Limi...