MODEL DESIGNATION MATRIX-
CLAMPED PLASTIC
SECTION
2
PR
ODUC
T SERIE
S
FL
UID CONNE
CTION T
YPE
LIQ
UID SE
CTION
DIAPHRA
GM
VAL
VE/B
ALL
VAL
VE SEA
T
O-RINGS
SPE
CIAL (
OTHER)
SPE
CIAL (P
OR
TING)
AIR SE
CTION
SPE
CIAL (HARD
WARE,
MUFFLER)
C 1 0 0
-
1 2
3
- 4 5 6 7 - 8 9 10
FLUID CONNECTION TYPE
N = NPT
B = BSPT
AIR SECTION
P = Polypropylene Intermediate-Pneumatic Shift
LIQUID SECTION
K = PVDF
P = Polypropylene
DIAPHRAGMS
G = Geolast
®
S = Santoprene
®
T = PTFE with Santoprene
®
Backup
V = FKM
VALVE/BALL
G = Geolast
®
S = Santoprene
®
T = PTFE
V = FKM
3 = Stainless Steel
VALVE SEAT
K = PVDF
P = Polypropylene
3 = Stainless Steel
O-RINGS
E = EPDM
N = Buna-N
T = PTFE
V = FKM
PORTING
G = Default (Suction Center Rear / Discharge
Center Rear)
L = Suction Bottom / Discharge Center Rear
SPECIAL OPTION (HARDWARE,
MUFFLER, LUG)
7 = Stainless Steel Hardware, Standard Muffler
8 = Stainless Steel Hardware, Premium Muffler
B = PTFE Coated Stainless Steel Hardware,
Standard Muffler
C = PTFE Coated Stainless Steel Hardware,
Premium Muffler
F = Stainless Steel Hardware, Standard Muffler,
Grounding Lug Installed
G = Stainless Steel Hardware, Premium Muffler,
Grounding Lug Installed
H = PTFE Coated Stainless Steel Hardware,
Standard Muffler, Grounding Lug Installed
I = PTFE Coated Stainless Steel Hardware,
Premium Muffler, Grounding Lug Installed
Note: Equipment must be grounded to achieve
ATEX rating it is recommended to configure
the pump with a grounding lug option for
ATEX applications.
SPECIAL OPTION (OTHER)
0 = Standard
1 = Cycle Counter Valve
2 = Solenoid Adaptor Valve 110/50 Volt AC, 120/60
Volt AC, DIN 43650B Connector
3 = Solenoid Adaptor Valve 110/50 Volt AC, 120/60
Volt AC Explosion Proof
4 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 12 Volt DC, DIN 43650B Connector
5 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 12 Volt DC Explosion Proof
6 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 125 Volt DC, DIN 43650B Connector
7 = Solenoid Adaptor Valve 220/50 Volt AC, 240/60
Volt AC, 125 Volt DC Explosion Proof
8 = Solenoid Adaptor Valve 24 Volt DC, DIN
43650B Connector
9 = Solenoid Adaptor Valve 24 Volt DC, Explosion
Proof
A = Grease Free (No lubrication assembly)
SIZE
WET END REPAIR KIT
Wet end kits are available and
consist of diaphragms, (back-up
diaphragms if required), balls,
seats and seat O-Rings.
See matrix below.
1
2
6
7
8
9
10
Bold indicates recommended options
AIR END REPAIR KIT
Air end repair kit contains pilot sleeve
assembly and main air valve.
DIAPHRA
GM
VAL
VE/B
ALL
VAL
VE SEA
T
O-RINGS
C
W
E
-
1
0
0
-
4
5
6
7
-
P
PR
ODUC
T
SERIE
S
WET END
REP
AIR KIT
PUMP SIZE
MA
TERIAL
C
A
K
-
1
0
0
-
P
PR
ODUC
T
SERIE
S
PUMP SIZE
AIR END
REP
AIR KIT
3
4
5
MA
TERIAL
Содержание PSG C100
Страница 1: ...IOM INSTALLATION OPERATION MAINTENANCE C100 PLASTIC 1 INCH AIR OPERATED DOUBLE DIAPHRAGM PUMP ...
Страница 6: ...ALF 13250 E 01 All Flo 6 1 PUMP DIMENSIONS CLAMPED PLASTIC SECTION 4 ...
Страница 18: ...ALF 13250 E 01 All Flo 18 EXPLODED VIEW PARTS LIST C100 SP CLAMPED PLASTIC SECTION 8 ...
Страница 23: ...ALF 13250 E 01 All Flo 23 NOTES ...