![Dover PSG C100 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/dover/psg-c100/psg-c100_installation-operation-and-maintenance-manual_2525014016.webp)
ALF-13250-E-01
All-Flo
16
PILOT VALVE REMOVAL
STEP 1
Using the screwdriver, remove
three “Phillips Pan-Head Screws”
in order to remove the “Retaining
Plate”. Repeat for other side of
the pump.
STEP 2
Remove the “Diaphragm Rod” and
the “Pilot Sleeve Assembly” from
the “Intermediate”.
STEP 3
Remove both “Lip Seals
(Diaphragm Rod)” and both “End
Spacers (Pilot Sleeve)” from the
“Pilot Sleeve Assembly”. Remove
both “O-Rings (End Spacer)” from
both “End Spacers (Pilot Sleeve)”.
TOOLS NEEDED
1) One Screwdriver, Phillips #2
2) Two Wrenches,
7
/
16
Inch
WARNING
Prior to servicing the pump, ensure that the air
and fluid lines are closed and disconnected. While wearing personal
protective equipment, flush, drain and process liquid from the
pump in a safe manner.
WARNING
Maintenance must not be performed when a hazardous
atmosphere is present.
STEP 4
Remove three “Inner Spacers
(Pilot Sleeve)” and four “O-Rings
(Pilot Sleeve)” from the “Pilot
Sleeve Assembly”.
STEP 6
Remove the “Pilot Sleeve” from
the disassembled “Diaphragm
Rod Assembly”.
REPAIR AND ASSEMBLY
STEP 5
Using two 7/16 inch wrenches,
disassemble the “Diaphragm Rod
Assembly” into its two parts.
Note: They are installed with
thread locker.
Содержание PSG C100
Страница 1: ...IOM INSTALLATION OPERATION MAINTENANCE C100 PLASTIC 1 INCH AIR OPERATED DOUBLE DIAPHRAGM PUMP ...
Страница 6: ...ALF 13250 E 01 All Flo 6 1 PUMP DIMENSIONS CLAMPED PLASTIC SECTION 4 ...
Страница 18: ...ALF 13250 E 01 All Flo 18 EXPLODED VIEW PARTS LIST C100 SP CLAMPED PLASTIC SECTION 8 ...
Страница 23: ...ALF 13250 E 01 All Flo 23 NOTES ...