4. Troubleshooting
Your Groen kettle is designed to operate smoothly and efficiently if properly maintained. However, the
following are checks to make in the event of a problem. Wiring diagrams are inside the service panel.
USE OF ANY REPLACEMENT PARTS OTHER THAN THOSE SUPPLIED BY GROEN OR THEIR
AUTHORIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE
EQUIPMENT AND WILL VOID ALL WARRANTIES.
SYMPTOM
WHO
WHAT TO CHECK
Burners will not light.
User
a.
Is main gas valve open (handle in line with gas
pipe)?
b.
Gas supply to your building.
c.
Is electric power turned on at the circuit breaker or
fuse box, and is power being supplied to the
appliance
d.
Thermostat operation.
Kettle continues heating after it
User
a.
Thermostat dial setting.
reaches the desired temperature.
Auth
b.
Thermostat calibration.
Y
Service
c.
Thermostat operation. Thermostat should click when
Rep Only
the dial is rotated above and below a setting.
Y
Kettle stops heating before it
User
a.
Thermostat dial setting.
reaches the desired temperature.
Auth
b.
Thermostat calibration.
Y
Service
c.
Thermostat. Thermostat should click when the dial is
Rep Only
rotated above and below a setting.
Y
Kettle heats slowly
User
a.
Air in jacket - pressure/vacuum gauge (20 to 30
below zero when the kettle is cold?)
Safety valve pops.
User
a.
Air in jacket - pressure/vacuum gauge (20 to 30
below zero when the kettle is cold?)
b.
Whether kettle was being heated while empty.
Auth
c.
If high pressure limit switch is set too high.
Y
Service
d.
Thermostat. Thermostat should click when the dial
Rep Only
is rotated above and below a setting.
Y
e.
Safety valve. If valve pops below 300 PSIG,
replace.
Y
System does not produce a spark
Auth
a.
Thermostat: close the contacts if they are open
Y
Service
b.
AC voltage between terminals “1" and “GR.” If it is
Rep Only
not 230 Volt, check the high limit switch, which
should be closed.
Y
c.
That the high tension cable is firmly attached and in
good condition. If cracked or brittle, replace the
pilot.
Y
e.
Electrode ceramic for crack or break.
Y
f.
Replace the electronic spark ignition module.
Y
Spark is present but the pilot will not
Auth
a.
That the gas valve is opening.
Y
light.
Service
b.
That pressure meets the control manufacturer’s
Rep Only
specifications.
Y
c.
For gas at the pilot. If it is not flowing:
(1) Check pilot gas line for kinks or obstructions.
Y
(2) Clean orifice, if necessary.
Y
(3) Replace the pilot valve.
Y
Pilot lights, but main burner will not
Auth
a.
That the gas pressure meets the control
come on and spark does not stay
Service
manufacturer’s specifications.
Y
on.
Rep Only b.
Replace electric module
Y