OM/SM-AH-CE
17
5. User Instructions
Regulations and Safety Precautions
These Appliances have been CE marked on the
basis of compliance with the Gas Appliance
Directive, EMC and Low Voltage Directive for
the Countries, Gas Types and Pressures as
stated on the Data Plate.
These appliances MUST BE installed by a
competent person in compliance with the
INSTALLATION AND SERVICING
INSTRUCTIONS and National Regulations in
force at the time. Particular attention MUST be
paid to the following:
I.E.E. Regulations for Electrical
Installations
Electricity at Work Regulations
Gas Safety (Installation & Use)
Regulations
Health and Safety at Work Act
Furthermore, if a need arises to convert the
appliance for use with another gas, a competent
person must be consulted. Those parts which
have been protected by the manufacturer MUST
NOT be adjusted by the User.
Users should be conversant with the appropriate
provisions of the Fire Precautions Act and the
requirements of the Gas Safety Regulations. In
particular the need for regular servicing by a
competent person to ensure the continued safe
and efficient performance of the Appliance.
WARNING
TO PREVENT SHOCKS, ALL APPLIANCES
WHETHER GAS OR ELECTRIC, MUST BE
EARTHED.
Upon receipt of the User's Instruction manual,
the installer should instruct the responsible
person(s) of the correct operation and
maintenance of the Appliance.
This equipment is ONLY FOR PROFESSIONAL
USE, and shall be operated by QUALIFIED
persons. It is the responsibility of the Supervisor
or equivalent to ensure that users wear
SUITABLE PROTECTIVE CLOTHING and to
draw attention to the fact that, some parts will,
by necessity, become VERY HOT and will cause
burns if touched accidentally.
5.1
Equipment Description
5.1.1 General
The kettle is charged at the factory with treated,
Groen AH models are stainless steel, steam-
temperatures of 65° C to 134° C. Controls for the
jacketed, floor mounted, stationary kettles with a
unit include a thermostat, pressure gauge, gauge
self-contained, gas heated steam source. The
glass, safety valve, pressure limit control, low
kettle body is welded into one piece and is
water cut-off, on/off switch, and a multi-
sheathed in stainless steel and insulated with
functional gas control valve.
fiber bat insulation. The interior and exterior are
given a bright buff finish.
Service connections are required for gas and
The unit is ASME shop inspected and registered
Paragraph 3.4 - Water Treatment.
with the National Board for working pressure up
to 30 PSIG. Kettle controls are contained in an
IMPORTANT
enclosed stainless steel enclosure. The unit rests
on tubular legs with adjustable ball feet. AH
Prior to operation, clean out the kettle pan
kettles come standard with stainless steel covers
thoroughly using hot water and detergent.
and two inch (five cm) sanitary tangent draw-off
Rinse out and dry completely.
valve.
The self-contained steam source is heated by
propane or natural gas. Ignition is by electronic
spark.
distilled water. The steam source provides kettle
230-V, single phase 50-Hz electricity. See
Содержание GROEN AH-20
Страница 23: ...OM SM AH CE 23 ...
Страница 24: ...OM SM AH CE 24 Parts Lists ...