Display message
Meaning
Cause
Action
A
fl
ashing thermometer shows in
the display.
When a selection button is
pressed, the text “PLEASE
WAIT” is also shown.
The water in the boiler is not yet
at the correct temperature.
The dispenser is deactivated until the
temperature has reached the value set.
A temperature value (°C of °F)
shows in the display.
The temperature in the cooling
compartment can not be
maintained at 2 - 5 °C or
35.6 - 41 °F.
Check that the cooling compartment door is
properly closed.
Check whether the temperature of the coffee
pack is considerably higher than 2 - 5 °C or
35.6 - 41 °F (also check that the pack is not
frozen).
Place a properly precooled coffee pack in
the cooling compartment.
Check whether there is clearance for
ventilation at the rear side of the dispenser.
Remove the
fi
lter grid at the back of the
dispenser and clean the
fi
lter if it is dirty.
Give the dispenser time to cool, the signal
disappears then automatically.
The icon “OUT OF ORDER” with
info no. 20 shows in the display.
The water supply is blocked or
the tap is not open.
Check the water supply and then press the
power switch twice to reset the dispenser.
Contact the service provider if the signal
does not disappear.
37
please wait
out of order