background image

6

Attaching the Foot Filter and Priming Tubing 

Grab the Clear 

flexible PVC Tube 

included with your pump. 

Cut the 

Tube

 in half, 

one piece for the Priming 

Valve and the other one

for the Suction Valve. 

Attach the end of one of 

the sections to the 

Suction Valve and the 

other end to the Foot 

Filter, following 

procedure in Step 16. 

Make sure the Foot 

Filter sits comfortably 

in the chemical container.

Slide the second 

section of the 

Clear Flexible 

PVC Tube onto 

the Priming Barb. 

Place the other 

end of the tube 

inside the 

chemical container.

Next, connect 

the pump to the 

Water Meter

 

(see steps 

28 - 33 below).

CONNECTING THE WATER METER - You will need a punch and a small flat head screwdriver

To connect the pump to 

the 

Water Meter

, remove 

the bottom front cover 

from the pump, using a 

flat head screwdriver.

Remove the rubber 

cap on the left.

Using a punch tool,

punch a small hole

through the rubber

cap.

Insert the 

Water Meter

wires through the hole

in the rubber cap.

Run the wires back 

through the hole in the 

front cover and reinsert

the rubber cap.

Insert the wires into 

terminals 3 and 4 from left

(push the buttons to insert).

Make sure they are 

connected properly 

and secured.

24

25

26

27

28

29

Tubing Connection - Water Meter Wiring

30

31

32

33

Содержание Dilution Solutions MDE0110MF.75KIT

Страница 1: ...3 4 Micro Doser Kit Manual NOTE Installation illustrations are to be used as a reference guide only Part MDE0110MF 75KIT...

Страница 2: ...age Threaded Union BK034 U 2 Check Valve CV34 PH 1 Tee TT34 1 to Reducer Bushing RB75 50ET 1 Close Nipple NIP075 2 3 Thread Tape TEF12 1 Included in the MicroDoser Kit Micro Doser Kit Contents PACK Pa...

Страница 3: ...art Part Number Qty Part Image Digital Manual Support Videos QR Tag TAG MD 1 1 PACK Part Part Number Qty Part Image eOne MF 0110 PEU483891MEA 1 tubing kit One pump PACK Part Part Number Qty Part Image...

Страница 4: ...image Hand tighten the Nut Wrap Thread Tape 4 to 5 times on all threads Make sure to wrap tape clockwise to prevent from unraveling Attach a Union to the inlet side of the Water Meter Make sure the ar...

Страница 5: ...e the arrow on the Mixing Chamber points in the direction of the flow Insert the third Close Nipple in the outlet of the Mixing Chamber and attach the last Union to the other side of the Close Nipple...

Страница 6: ...o not overtighten Take your pump from its box and mount it on the wall using the bracket included with the pump Grab the Opaque Rigid Polyethylene Discharge Tube ORPDT included with the pump and cut i...

Страница 7: ...e to the threads level see image Insert the Injection Valve into the Reducer Bushing at the top of the Tee in the Micro Doser Plumbing Assembly hand tighten only Anchor the Micro Doser Plumbing Assemb...

Страница 8: ...chemical container Next connect the pump to the Water Meter see steps 28 33 below CONNECTING THE WATER METER You will need a punch and a small flat head screwdriver To connect the pump to the Water Me...

Страница 9: ...air bleed nut Push the START STOP button to begin the priming functions The pump will begin to stroke click Once the chemical starts going down the air bleed tube re tighten the air bleed nut back up...

Страница 10: ...TART STOP button to begin the program operation You can now turn on the irrigation water to begin operation of the system using the water meter 7 8 9 10 See operating manual for complete instructions...

Страница 11: ...ed injection will be minimal but fluctuations may be noticeable at very low or very high flow rates See USING THE PRESSURE RELIEF VALVE to decrease the Single Pulse Volume to a volume that divides eve...

Страница 12: ...IC TESTING PROCEDURE steps Repeat steps 3 4 as necessary until desired Single Pulse Volume is reached 1 2 3 4 5 Black Protection Cap Counter Nut Adjustment Screw Volumetric Testing Procedure You can t...

Страница 13: ...e Settings Press button the screen should read PULSES MINUTE PULSES NUM 300 Press buttons to set PULSES MINUTE to 100 100 pulses min Press the button to save the new PULSE MINUTE settings Open Test Du...

Страница 14: ...iner from the graduated cylinder and place the suction strainer back in the concentrate container Return concentrate solution remaining in graduated cylinder to concentrate container to eliminate wast...

Страница 15: ...Chamber Sunshade sleeve prevents the light from impacting nutrient rich water eliminating the potential for biofilm and algae growth in the chamber Now attach the QR Code tag included to the MicroDos...

Страница 16: ...Dilution Solutions 2090 Sunnydale Blvd Clearwater FL USA 1 800 451 6628 727 451 1198 www dilutionsolutions com...

Отзывы: