IMPORTANT ! - Do not put the suction tube strainer on the bottom
of the stock solution container. The strainer must be suspended at
least 10 cm [4”] above the bottom of the tank to avoid sucking up the
insoluble particles that may damage the injection assembly (Fig.2).
- Do not put the strainer on the ground.
Under no circumstance should the solution level be above the water
inlet of the DOSATRON (to avoid siphoning situations) (Fig. 3).
ASSEMBLING THE DOSATRON (cont...)
10 cm
4”
Fig. 2
Fig. 3
WHAT YOU SHOULD DO
WHAT YOU MUST NOT DO
NO !
INSTALLATION HINTS
EXCESSIVE FLOW
(as an indication).
If your DOSATRON clicks more than
46 times
, that is
23 cycles
in 15 seconds
, you are close to the superior flow limit. If you need
more flow, you must install a DOSATRON with a superior capacity
of flow.
The DOSATRON can be
connected to the main water line
directly (Fig. 4)
, on a
by-pass
(Fig. 5).
If your flow rate is above the
operating limits of the DOSATRON,
see § EXCESSIVE FLOW.
To prolong the working life of the
DOSATRON it is advisable to
install a filter (ex.: 300 mesh - 60
microns depending on your water
quality) upstream.
This is imperative if the water
contains impurities or particles,
especially if the water comes from
a well.
A filter is recommended and
required for the warranty to be
valid.
Installing the DOSATRON on a
bypass enables clean water to
be supplied without operating the
DOSATRON and the DOSATRON
to be easily dismantled.
When connecting an
installation to the public
water supply, you must
respect the rules and
regulations in force in the
country.
Fig. 4
Check valve
Valve
Valve
Filter
Filter
Fig. 5