4.6 Mounting panel sections on the glass
door panel
Special tools:
• Torque wrench
1.
Rotate the panel sections up to the glass door
panel.
2.
Insert the glass protection rings into the pre-
drilled holes in the glass door panel.
3.
Mount the counter-plates to the panel section
through the glass door panel with the countersunk
screws. Tightening torque should be 12 Nm.
4.
Secure the countersunk screws on the frame
pivots with a tightening torque of 12 Nm.
Abb. 15
12 Nm
1.
3.
2.
Mount the panel section
4.7 Performing a function test on the door
1.
Remove all wooden blocks.
Abb. 16 Remove the wooden blocks
2.
Check the door gaps.
3.
Check that the door moves easily.
4.8 Mounting the end caps
1.
Remove the protective film from the adhesive
strips on the end caps.
2.
Stick the end caps onto the counter-plates.
Abb. 17
1.
2.
Glue the end cap in place
4.9 Using a doorstop (optional)
Use a doorstop to prevent the door from opening too
far.
Abb. 18
max
100°
Use a doorstop to prevent the door opening too far
10
STUDIO Rondo glass/glass
2018-09
WN 059480 45532
dormakaba Mounting instructions
Mounting