dormakaba ED100/ED250 Service Manual
Chapter 9
9.3 ED100/ED250 environment and cleaning
9.3.1 ED100/ED250 environmental requirements.
ED100/ED250 header assembly is designed to operate
on an interior building surface under the specifications
shown in Table 9.3.1.
9.3.2 Areas around door(s) and door swing radius.
Areas around doors and door swing radius must be kept
clear of all obstacles.
9.3.3 Cleaning
WARNING
Cleaning of header surfaces must be done with
program switch in Close position!
External surfaces of the header can be cleaned with a
damp cloth and commercial cleaning agents.
TIPS AND RECOMMENDATIONS
Abrasive (scouring) agents should not be used
as they may damage external surfaces.
9.3.4 Water and other liquids.
CAUTION
No water or other liquids must be sprayed or
spilled on ED100/ED250 header!
Table 9.3.1 Operator environmental requirements
Fig. 9.3.1 ED100/ED250 header
1
10
9.4 Yellow LED, service level
Fig. 9.4.1 Service level indicator
9.4.1 Service level indicator
Header cover must be opened to view operator LEDs.
Yellow LED on operator power switch side is service level
indicator. Operator system should be scheduled for
service when yellow LED is first illuminated, or annually,
whichever comes first.
TIPS AND RECOMMENDATIONS
Reference Chapter 14, parameters for
information on:
• Parameter CS, reset service interval display.
• Parameter CC, cycle counter.
4
5
6
3
3
Power switch
4
Red LED
5
Yellow LED
6
Green LED
Ambient temperature
5 to 122 °F
Suitable for dry
rooms only
Relative air humidity:
93% maximum, non-condensing