19
ED100/ED250
02-2018
DL4614-050
dormakaba ED100/ED250 Service Manual
Chapter 10
10.1 Reveal depth parameter rd
10 Measure reveal depth, parameter rd
Parameter
Description
2
rd
Reveal depth
10.3 rd parameter values
-1 3/16
-30
-3
-3/4
-20
-2
-3/8
-10
-1
0
0*
0
3/8
10
1
3/4
20
2
1 1/8
30
3
1 9/16
40
4
1 15/16
50
5
2 3/8
60
6
2 3/4
70
7
3 1/8
80
8
3 1/2
90
9
3 15/16
100
10
4 5/16
110
11
4 3/4
120
12
5 1/8
130
13
5 1/2
140
14
5 7/8
150
15
10.3.1 ED100/ED250 reveal depths, rd parameter
Reveal measurement
ED100/ED250
Inches
[mm]
rd
6 5/16
160
16
6 11/16
170
17
7
180
18
7 1/2
190
19
7 7/8
200
20
8 1/4
210
21
8 5/8
220
22
9
230
23
9 7/16
240
24
9 13/16
250
25
10 1/4
260
26
10 5/8
270
27
11
280
28
11 7/16
290
29
11 13/16
300
30
10.3.2 ED250 additional reveal depths, rd parameter
12 3/16
310
31
12 5/8
320
32
13
330
33
13 3/8
340
34
13 3/4
350
35
14 3/16
360
36
14 9/16
370
37
15
380
38
15 3/8
390
39
15 3/4
400
40
16 1/8
410
41
16 9/16
420
42
16 15/16
430
43
Reveal measurement
ED250
Inches
[mm]
rd
17 5/16
440
44
17 3/4
450
45
18 1/8
460
46
18 1/2
470
47
18 7/8
480
48
19 1/4
490
49
19 11/16
500
50
Parameter rd value
Reveal measurement
10.2 Record reveal depth
measurement, rd value
10.1.1 Reveal depth parameter.
1. Reveal depth is set in increments of 10 mm
(approximately 3/8").
2. Measured reveal depth of 30 mm (approximately
1 3/16") equals
rd
parameter value of 3.
*Factory setting
Fig. 10.1..1 CPD pull arm and lever with track
TIPS AND RECOMMENDATIONS
Use of CPD pull arm and lever (Fig. 10.1.1):
Value of parameter
rd
must be reduced by
3/16" [30].
• Example: ED250 with CPD pull arm and
lever in pull installation with reveal of
30 mm (1 1/8").
Parameter rd setting = 0
(Reveal of 30 mm - 30 mm).