28
ED100/ED250
02-2018
DL4614-050
dormakaba ED100/ED250 Service Manual
Chapter 15
Parameter and value
range, factory setting
=
bold
.
Parameter description
1
0 - 4
0
Installation type
0
• Pull arm with track, wall
mounting on swing (hinge) side
(Fig. 21.1.4).
• Pull arm and CPD lever with
track, wall mounting on swing
(hinge) side (Fig. 21.1.5).
Reference Para. 21.1.10 for door
reveal detail.
1
• Standard push arm,
wall mounting on approach
(non-hinge) side (Fig. 21.1.6).
2
• Push arm with track, wall
mounting on approach
(non-hinge) side.
• Application specific
3
• Overhead concealed (OHC), right
hand (v2.1)
4
• OHC, left hand (v2.1)
2
ED100
-3 to 30
ED250
-3 to 50
0
Reveal depth
0
Reveal is set in increments of
10 mm (3/8"), "3" = 30 mm (1 1/8").
• ED100
[-30 to 300 mm]
-1 3/16" to 11 13/16"
• ED250
[-30 to 500 mm]
-1 3/16" to 19 11/16"
• CPD lever, reference Para. 15.1.9.
Fig. 15.1.4 Pull arm with track
15.1.8 Configuration parameters, detail
Fig. 15.1.5 CPD pull arm and lever with track
Fig. 15.1.6 Standard push arm
3
Tb
ED100
7 to 12
ED250
7 to 15
10
Door width
10
Door width is set in increments of
100 mm (4"), "10" = 1000 mm (39.4").
• ED100: [700 - 1200 mm] 28" - 48"
• ED250: [700- 1500 mm] 28" - 60"
4
0 to 4
0
Door type
0
Single door
1
Double door
• Overlapping door (with astragal)
• Active door operator.
2
Double door
• Overlapping door (with astragal)
• Passive door operator.
3
Double door
• Edgeless door (no astragal)
• Active door operator.
4
Double door
• Edgeless door (no astragal)
• Passive door operator.
15.1.10 Push arm with track; reveal and installation
detail [Application specific].
15.1.9
CPD pull arm and lever rd parameter
adjustment.
• Value of parameter
rd
must be reduced by 3/16" [30]
when using the CPD pull arm in a pull installation.
• Example: ED250 with CPD pull arm and lever in pull
installation with reveal of 30 mm (1 1/8").
Parameter rd setting = 0 (Reveal of 30 mm - 30 mm).