background image

About this document

Technical Manual

7

04046493 - 11/2018

dormakaba Remote Reader 91 15 -

U300

1.8.2

Symbols

Symbols with the following meaning are used for warnings, depending on the source of
danger.

General hazard

Danger of damage to electronic
components from electrostatic dis-
charge

1.9

Notes

Notes are indicated by an info symbol.

Tips and useful information.
These help you make the best use of the product and its functions.

Содержание 91 15 LEGIC

Страница 1: ... AC AC B A C GND IN1 IN2 2 1 Push Click DIN Rail AS A OUT Output Ant Function 0 F 123456 ON OFF RS 485 Input Programmer Supply 10 34VDC 12 27VAC 34VDC Class II Relay Output 27VAC max 5VDC dormakaba Remote Reader 91 15 U300 04046493 11 2018 EN Technical Manual ...

Страница 2: ... 78056 Villingen Schwenningen Germany T 49 7720 603 0 www dormakaba com Company headquarters Villingen Schwenningen Copyright dormakaba 2018 All rights reserved No part of this document may be reproduced or used in any form or by any means without prior written permis sion of dormakaba Schweiz AG All names and logos of third party products and services are the property of their respective owners S...

Страница 3: ...des 11 3 4 Supported RFID standards with possible media definitions 12 3 5 Technical data 13 3 5 1 Overview of technical specifications 13 3 5 2 Dimensions 15 3 6 Conformity 16 3 7 Designation 17 4 Construction and function 18 4 1 RFID reader 18 4 2 Device construction 18 4 3 Firmware 19 4 4 System connection 20 4 5 System requirements 20 4 6 Behaviour when several media are present in the field a...

Страница 4: ...uthorization 33 6 3 2 Withdrawing individual write access issued via a write author isation 33 7 Maintenance 34 7 1 Programming interface 34 7 2 Restart 34 7 3 INI reset Reset the device to the basic state 35 7 3 1 INI reset with DIP switch 6 35 7 3 2 INI reset with the programming master 36 7 4 Question FW Update U300 37 7 5 Firmware update 37 7 6 Updating configuration with the programmer 1364 3...

Страница 5: ...ology Equipment Part 1 Safety Requirements Skilled person is the designation for people who have the appropriate technical training and experience in setting up the equipment Skilled persons are expected to use their training and experience to identify any risks to themselves and others that may arise while carrying out these activities and to minimise these risks as far as possible It is the skil...

Страница 6: ...bbreviation term Description Remote reader Remote reader 91 15 U300 Device Remote reader 91 15 U300 Registration unit Registration unit 90 00 Registration unit 90 01 Registration unit 90 03 Registration unit 90 04 System System software e g KEM KMM Kaba Media Manager 1 8 Warnings Warnings containing information instructions and prohibitions designed to prevent personal injury or damage are special...

Страница 7: ...s with the following meaning are used for warnings depending on the source of danger General hazard Danger of damage to electronic components from electrostatic dis charge 1 9 Notes Notes are indicated by an info symbol Tips and useful information These help you make the best use of the product and its functions ...

Страница 8: ...t up any damaged device Assembly and installation of the product may only be done by skilled personnel see chapter 1 Target group When installing inserting the product in end use equipment all requirements of the men tioned test standards must be fulfilled The product should only be installed in locations which fulfil the environmental and technical conditions specified by the manufacturer The man...

Страница 9: ...hed metal component This way static discharges are channelled away from your body safely and effectively Handle a PCB along its edges only Do not touch the PCB or connectors Place dismantled components on an anti static surface or in an anti static shielded con tainer Avoid contact between PCBs and clothing The wrist strap protects PCBs against an elec trostatic discharge voltage from the body onl...

Страница 10: ...ystem solutions The remote reader is installed on a DIN rail The door components lock elements are directly connected to the remote reader This is used to control the registration units electric strike and optical and acoustic signal transmit ters Maximum number of registration units 1 1 2 3 4 5 6 7 8 9 1 0 E ENTER 2 1 ABC 3 DEF 5 JKL 4 GHI 6 MNO 8 0 TUV 7 PQRS 9 WXYZ ENTER 2 1 ABC 3 DEF 5 JKL 4 G...

Страница 11: ...tration units are supported Registration unit 90 00 Registration unit 90 01 Registration unit 90 03 Registration unit 90 04 3 3 Operating modes The door configuration determines the device operating mode A detailed description of door configurations and their corresponding operating modes can be found in the chapter Electric strike operating mode ...

Страница 12: ... standards with possible media definitions The following table indicates the RFID standards and media definitions supported by the device Media definitions Supported RFID technologies LEGIC prime LEGIC RF Safe UID Card ID Kaba Group Header Kaba advant ID LEGIC access advant LEGIC access pool prime CardLink 1 0 ...

Страница 13: ...er supply the clock will run for at least 120 hours after a minimum of 10 minutes of operation Only power supply units that fulfil the following requirements may be used for power supply LPS Limited Power Source and SELV Safety Extra Low Voltage in accordance with IEC EN UL CSA 60950 1 or ES1 and PS2 in accordance with IEC EN UL CSA 62368 1 Interfaces HF RFID 1 registration unit Coaxial cable impe...

Страница 14: ... DC 2 A Typ 100 000 LED status display Only power supply units that fulfil the following requirements may be used for power supply of the relay inputs LPS Limited Power Source and SELV Safety Extra Low Voltage in ac cordance with IEC EN UL CSA 60950 1 or ES1 and PS2 in accordance with IEC EN UL CSA 62368 1 Ambient conditions Operating temperature 0 C to 50 C Storage temperature 20 C to 65 C Relati...

Страница 15: ...l Manual 15 04046493 11 2018 dormakaba Remote Reader 91 15 U300 3 5 2 Dimensions Dimensions in millimetres AS AC AC Supply Output Input RS 485 Ant A A B C IN1 IN2 DIN Rail 2 1 Push Click 012 3 4 5 6 7 8 9 A B C D E F 70 87 106 45 ...

Страница 16: ...nditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation FCC 15 21 Warning Statement Any changes or modifications not expressly approved by the party responsible for compli ance could void the user s authority to operate the equipment FCC 15 105 Note This equipment has been tested and...

Страница 17: ...x CNR d Industrie Canada applicables aux appareils radio exempts de licence L exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage 2 l utilisateur de l appareil doit accepter tout brouillage radi oélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement 3 7 Designation The rating plate is located on the side of th...

Страница 18: ...9 A B C 91 15 State IN1 IN2 OUT GND AC AC B A C GND IN1 IN2 2 1 Push Click DIN Rail AS A OUT Output Ant Function 0 F 123456 ON OFF RS 485 Input Programmer Supply 10 34VDC 12 27VAC 34VDC Class II Relay Output 27VAC max 5VDC 1 2 3 4 5 6 7 8 9 10 1 not used 2 DIP switch 3 Rotary switch 4 Registration unit connection 5 LED indicators 6 not used 7 Relay output OUT 8 Inputs IN1 IN2 IN2 not in use 9 Inte...

Страница 19: ...B MRD Multi RFID Device LEGIC or MIFARE determined on commissioning Device type RC Compact reader RP Compact reader 91 12 RR Remote reader 91 15 RE Remote reader 91 25 AM Access manager Function type A E3xx or N300 T300 U300 V3 B Access manager C Subterminal E AMC II cDML Version number xx xx Version Add on 1 R Final and approved version Add on 2 A Subversion Add on 3 _ Reserved Example Firmware d...

Страница 20: ...g for electric strikes The Functions 4 7 chapter provides information on additional functions Registration unit functions Reading the media presented RFID Optical and acoustic signalling 4 5 System requirements Standalone mode System software KEM KEM 3 0 and above Kaba exos Kaba exos 2 3 and above 4 6 Behaviour when several media are present in the field anti collision The device Remote reader 91 ...

Страница 21: ...horisation types are saved in the Remote reader via pro grammer 1364 The authorisation check and access control are therefore sensed by the Re mote reader Line U300 Function Master A 1 Master B 200 Whitelist user or group ID 2200 CardLink 1 0 LEGIC prime X Time profiles 15 always Time window for every time profile 12 Holiday periods 10 Special days 32 TimePro functions X TwinTime X Group authorisa...

Страница 22: ... 4 8 Electric strike operating mode 1 2 3 1 Remote reader 91 15 U300 2 Electric strike 3 Door opener key The Electric strike operating mode is mainly used to operate doors with electric locking ele ments strike magnet The electric strike is triggered by an authorized booking or the door opener key ...

Страница 23: ...amper proof area Ambient conditions see Chapter on Technical data In a housing unit or IT cabinet on a DIN rail in accordance EN 60715 Electromagnetic fields Do not install the device in the vicinity of strong electromagnetic fields caused for example by switched mode power supplies electric power lines phase control etc 5 1 3 Connections The following connections must be prepared at the device s ...

Страница 24: ...C State IN1 IN2 OUT GND AC AC B A C GND IN1 IN2 AS A OUT Output Ant Function 0 F 123456 ON OFF RS 485 Input Programmer Supply 10 34VDC 12 27VAC 34VDC Class II Relay Output 27VAC max 5VDC 1 Remote reader 2 Registration unit 3 Door opener 4 Power supply Installation cables A Power supply cable B Line to the door opener C Coaxial cable ...

Страница 25: ...ith a core diameter of between 0 5 mm and 0 8 mm Recommended line CAT 5 S UTP 4 x 2 AWG 24 or AWG 22 in accordance with EIA TIA568 or higher 5 3 3 Coaxial cable to the registration units Cable type RG174 U Coaxial cable 50 Ohm item no 161 250 Maximum cable lengths Cable type RG174 up to 30 m Cable type RG178 U up to 30 m Recommended cable length 10 m Max cable length 30 m 5 3 4 Grounding concept 5...

Страница 26: ... and keep pressing it 2 At the same time push the device up against the rail until it can be mounted on the rail Dismantling NOTICE Removing the device under voltage may cause damage Disconnect the device from the power supply before removing it Dismantling the Remote reader Push 1 2 1 Disconnect the device from the power supply 2 Disconnect the device Registration unit 3 Disconnect the device fro...

Страница 27: ...tion unit 2 not used 3 Relay output OUT Contact rating 30 V AC DC max 2 A 4 Digital input IN1 Door opener key REX without line monitoring or door handle contact Switch to ground GND using a switch or relay contact Digital input IN2 not used 5 Interface for Programmer 6 Power supply 12 27 V AC 50 60 Hz or 10 34 V DC 7 The device may only be supplied with SELV Safety Extra Low Voltage and LPS Limite...

Страница 28: ... 6 Inputs IN1 IN2 NOTICE Connect the inputs making sure they are potential free The function of the inputs and outputs depends on the control used and their parameter set tings Occupancy Meaning GND common ground IN1 input 1 Door opener key REX or door handle contact IN2 input 2 not used ...

Страница 29: ...de for door openers with a DC voltage supply or a varistor for door openers with an AC voltage supply Pos Meaning Relay output OUT NC normally closed COM NO normally open Contact rating See FEHLENDER LINK 5 7 1 Note on using door openers The relay can be used to control the door opener For door openers powered by a DC power supply a free wheeling diode must be installed in parallel in the locking ...

Страница 30: ...en switched off and on again 5 8 2 Setting the switches 01 2 3 4 5 6 7 8 9 A B C 91 15 State IN1 IN2 OUT GND AC AC B A C GND IN1 IN2 2 1 Push Click DIN Rail AS A OUT Output Ant Function 0 F 123456 ON OFF RS 485 Input Programmer Supply 10 34VDC 12 27VAC 34VDC Class II Relay Output 27VAC max 5VDC 1 2 1 DIP switch 2 Rotary switch The device switch settings can be adjusted as described below 5 8 2 1 D...

Страница 31: ... 0 If the rotary switch is not set to position 0 the device will behave in accordance with the rotary switch setting Upon delivery the rotary switch is set to 0 pulse mode 1 default setting Adjust the mode function using the rotary switch Position Mode function Position Mode function 0 Pulse mode de fault 1 s 8 Pulse mode 60 s 1 Pulse mode 0 5 s 9 120 s 2 1 s A 300 s 3 2 s B Not used 4 5 s C Not u...

Страница 32: ...status actuator status If the Remote reader is intended to read a read protected segment of a medium In this chapter the term write authorisation shall be used to refer to both write authorisa tion and read authorisation Write authorisation with a LEGIC prime SAM 63 card is only valid for LEGIC prime The signal is output by the registration unit at which the card is presented Requirement A LEGIC p...

Страница 33: ...thorization Reset the remote reader to the basic state 6 3 2 Withdrawing individual write access issued via a write authorisation Delete the relevant stamp using the LEGIC prime SAM 64 card The signal is output by the registration unit at which the card is presented Requirement A LEGIC prime SAM 64 card with the relevant segment range is required in order to with draw write authorisation The Remot...

Страница 34: ...8 9 10 7 2 Restart Effects of a restart Duration approx 3 s The access point is blocked during restart The saved parameter settings and data remain in place The device is restarted Procedure 1 Switch the power supply off and then on again ð The State LED goes out ð The access point is blocked 2 After the restart the State LED changes back to green If the power is disrupted for longer than the indi...

Страница 35: ... supply 2 Set DIP switch 6 to ON Switching the DIP switch when the device is still connected to the power supply will have no effect 3 Connect the remote reader to the power supply ð Green and red flash after two short acoustic signals The remote reader LEDs flash orange ð The remote reader is reset to the factory setting for the other effects see above Consequences of an INI reset 4 Disconnect th...

Страница 36: ...ls will sound and the green light will remain continuously illu minated ð After 15 s the INI reset will start ð Two short acoustic signals sound and the visual displays on the registration unit and the remote reader go out 2 Once the INI reset is complete remove the programming master ð The device is back in operation ð Registration unit The visual display is illuminated green or switched off Remo...

Страница 37: ...364 2 Disconnect the device from the power supply Switching DIP switches 5 and 6 has no ef fect when the device is connected to the power supply ð The access point is blocked during the firmware update 3 Turn DIP switches 5 and 6 to ON 4 Connect the device to the power supply ð Remote reader the IN1 LED flashes green ð Registration unit flashes green and red after two short acoustic signals 5 Conn...

Страница 38: ...stration unit The visual display is illuminated green or switched off 7 7 Crossgrade A crossgrade can be used to change the functional type of a device For example a device with the Access Manager AM functional type can be converted into a device with the func tional type E300 V4 or subterminal The programmer 1460 user manual document no k1evo809 explains how to change the func tional type of a de...

Страница 39: ...chno logy using a programming mas ter Site changed by user Adjust site New sources of interference e g new or replaced hubs cash ma chines or other security systems Reduce the influence of the sources of interference increase distance shielding Cabling changed Adjust the cabling Medium used incorrectly Inform users about how to cor rectly use the medium Remote reader not writing to media LEGIC onl...

Страница 40: ... Electrical and Electronic Equipment Act ElektroG in Germany dic tates that facility operators are obliged to return electrical and electronic devices to their manufacturer point of purchase or designated public collection points at the end of their life cycle Disposal in Germany dormakaba EAD GmbH will take responsibility for correct disposal of supplied goods once they are no longer in use as pe...

Страница 41: ...assemblies such as PCBs and readers should be stored transported and shipped in suitable anti static packaging Electronic component assemblies must be packed at ESD protected workstations This should be carried out by persons who are familiar with and comply with general ESD protection regulations Electronic component assemblies must be returned in packaging with sufficient ESD protec tion to make...

Отзывы: