7
DIP SWITCH SETTING FOR SECURITY DOOR LOCK
1
O N
0 S e c .
N u is a n c e D e la y
D ip S w it c h 1 & 2
2
3
4
2 S e c .
4 S e c .
6 S e c .
0 S e c .
R e m o t e A la r m
D ip S w it c h 3 & 4
1 5 S e c .
3 0 S e c .
In f in it y
5
1
O N
2
3
4
5
1
O N
2
3
4
5
1
O N
2
3
4
5
1
O N
2
3
4
5
1
O N
2
3
4
5
1
O N
2
3
4
5
1
O N
2
3
4
5
D. POWER REQUIREMENTS
Power Input
Accept power in the range of 12 ~ 30 VDC
Power Consumption
12 VDC – MAX. 0.55A. (with all relays on, no buzzer)
24 VDC – MAX. 0.27A. (with all relays on, no buzzer)
Output Relays
Local Alarm Output –
Form C: 1.0A 120VAC, 2A 30VDC.
Remote Alarm Output –
2 Form C: 1.0A 120VAC, 2A 30VDC.
Wires Requirement
12 ~ 30 VDC Power Input – 2 wires.
Local Alarm Relay Output – 1 x 3 wires.
Remote Alarm Relay Output – 2 x 3 wires.
Reset Input – 2 wires.
Motion Detector Input – 2 wires.
Voice Control Output – 4 wires.
Request to Exit Input – 2 wires.
9 VDC/Max 1A Power Output – 2 wires.
9 VDC/Max 100mA Output to Buzzer – 2 wires.
Operating Temperature
-10 to +60 degree C.
E. OTHER FUNCTIONS
Motion Detector Input
(MD)
Normally Open.
These two terminal block inputs are used for Delay
Egress Function. The system will start the delay
sequences only when these two inputs are shorted.
Voice Control Output
(S2, S1, G, 5V)
Four terminal block outputs to control Voice Module.
Request to Exit Input
(EXIT)
Normally Open.
The lock will release for 5 seconds when these two
terminal block inputs are momentarily shorted, and will
release all the time as long as these two terminal block
inputs are shorted.
Reset Switch Input
(RST)
Reset Switch Input from OPEN to CLOSE will reset the
system back to the normal condition.
9 VDC Power Output
System provides 9 VDC/Max. 1A output.
Low Voltage Detection
Jumper selectable to release the lock when system
detects 10 VDC low voltage.
Remote Alarm Relay “off”
Remote Alarm Relay is off only “when lock is released” or
“when lock is going to be released” or “when lock might
be forced to be released”.
F. SETTINGS & WIRINGS
1
ON
EXIT
Lo
ca
l
2 3 4 5
Alarm
Remote
Alarm
RST
NC
NO
C
NC
NO
C
MD
S1
5V
NC
NO
C
S2
DC
G
BZ1
W1
remote B
local
remote A
MAG
W2
R
B
G
HI
C
JP
R
B
G
LE
D
voice module
motion
detector
power
exit
switch
reset
switch
BZ1: 9 VDC output to Buzzer.
MAG: connect to magnet.
HIC:
connect to Hall IC.
LED: connect to bi-color LED.
W1:
open to enable low voltage detection.
short to disable low voltage detection.
W2:
connect to micro switch.
JP:
short to connect 9 VDC to C on remote B.