background image

 

 

EARLY WARNING ALARM SYSTEM STATUS 

 

System 

Status 

Light Panel 

Local 

Buzzer 

Voice 

Local  

Alarm Relay 

Remote 

Alarm Relay

Door Open 

Red 

on 

OFF OFF OFF OFF 

Lock 

Locked 

Green blinks 

every 5 

seconds 

OFF OFF OFF  ON 

Nuisance 

Delay 

Period 

Red blinking 

(fast) 

Sound 

pulsingly 

Voice I 

ON 

ON 

Remote 

Alarm 

Period 

Red blinking 

(slowly) 

Sound 
steady 

Voice IV 

ON 

OFF 

Remote 

Alarm  

Time Out 

Red/Green 

blinking 

alternately 

OFF OFF OFF  ON 

Force to 

Open 

Red blinking 

(fast) 

Sound 

pulsingly 

Voice IV 

ON 

OFF 

Exit Switch 

to Open 

Red on 

OFF 

Voice III 

OFF 

OFF 

 

Voice I: 

Unauthorized personnel prohibited. 

 

 

(Max. 4 second periods for Voice I) 

Voice II:  The emergency exit system has been activated, the door will unlock in a moment. 

(Max. 8 second periods for Voice II) 

Voice III:  The door is now unlocked, please exit. 

 

 

(Max. 8 second periods for Voice III) 

Voice IV:  Illegal intruder. The security alarm is activated. Security personnel has been 

alerted and would arrive momentarily. 

(Max. 10 second periods for Voice IV) 

 

Voice Module is optional. 

“Force to Open” can only be turned off by switching off the system power. 

After “Exit Switch to Open” is timeout, system is back to the normal condition. 

 

 

Local

N

o

rm

a

l Cond

it

ion

N

u

isan

ce Del

a

y

R

emot

e Al

ar

m

R

eset

 to

(P

o

w

e

r on

 &

 Doo

r Locked

)

Per

iod

N

o

rm

a

l Co

nd

it

ion

Re

mo

te

L

o

cal

 B

u

zzer

Voi

ce Messag

e

V

o

ic

e Message I

V

oi

ce Mess

age IV

Pe

rio

d

 0 

~ 6 Se

conds 

Al

ar

m

 R

e

lay

Al

ar

m

 R

e

lay

en

e

rgi

z

e

d

d

eenergi

zed

en

e

rgi

z

e

d

d

eenergi

zed

on

of

f

Early W

a

rning Alarm Functions

(P

o

w

e

on

 &

 D

o

o

Locked)

E

x

it

 Sw

it

ch t

o

 Open

F

o

rc

e t

o

 O

p

en

C

a

n be "Ex

it

 Swi

tch

 t

o

 Op

en" in

 th

is peri

od - 

Voi

ce Messag

II

I

A

ft

e

"

E

xi

t Sw

it

ch to O

p

en" 

is t

imeou

t,

 sys

tem wi

ll

 be ba

ck t

o

 t

h

e normal

 condi

ti

on

Rem

o

te

 Al

arm

Ti

m

e

out

 0 or

 15 o

r 30 or

In

fi

nit

e

 S

e

conds

Can be "Fo

rce

 to

 O

p

en"

 i

n

 t

h

is

 period

 -

 Voi

ce Message I

V

Содержание EM 3000-EW AH

Страница 1: ...on the door is fail safe power to lock and locked the local buzzer is off the Local Alarm Relay SPDT 1C is deenergized and the Remote Alarm Relay DPDT 2C is energized The system will start the exit se...

Страница 2: ...fast Sound pulsingly Voice IV ON OFF Exit Switch to Open Red on OFF Voice III OFF OFF Local Normal Condition Nuisance Delay Release Delay Door Release Reset to Power on Door Locked Period Normal Condi...

Страница 3: ...ry setting Not BOCA Dip switch 4 ON 1 5 S e c R e le a s e D e la y D ip S w itc h 1 3 0 S e c 1 O N 0 S e c N u is a n c e D e la y D ip S w itc h 2 3 2 3 4 1 S e c 2 S e c 3 S e c N o n B O C A B O...

Страница 4: ...t Max 8 second periods for Voice III Voice IV Illegal intruder The security alarm is activated Security personnel has been alerted and would arrive momentarily Max 10 second periods for Voice IV Voice...

Страница 5: ...em will start the delay sequences only when these two inputs are shorted Voice Control Output S2 S1 G 5V Four terminal block outputs to control Voice Module Request to Exit Input EXIT Normally Open Th...

Страница 6: ...message by speaking to the microphone on the voice module or by connecting ANA to computer earphone output and playback the voice message thru such as Windows Media Player The messages can also be rec...

Страница 7: ...nly when Reset Switch Input from open to close NOTE NOTE N Buzzer Off Buzzer Off Flow Chart for NFPA 101 N Y LEDR Blinking Fast Local Alarm On Remote Alarm On Buzzer Pulsing Nuisance Delay Time Out Di...

Страница 8: ...Y LEDR Blinking Fast Local Alarm On Remote Alarm On Buzzer Pulsing Nuisance Delay Time Out Dip Switch Setting Dip1 On 15 Sec Off 30 Sec Dip2 Dip3 On Off 1 Second Dip4 Off Power On Locked Door Pushing...

Страница 9: ...to close NOTE NOTE N for CANADA Buzzer Off Buzzer Off Flow Chart for BURGLAR ALARM N Y LEDR Blinking Fast Local Alarm On Remote Alarm On Buzzer Pulsing Nuisance Delay Time Out Power On Locked Door Pus...