1.2.4 Combustion products discharge safety
device
The heater has been fitted with a combustion products
discharge safety device. It is the function of the safety
device to prevent flue gases from the water heater
entering the room where the water heater has been
placed, instead of passing through the flue to outside
atmosphere. The gas supply is disconnected as soon as
hot gases flowing over the sensor activate the device.
After the cause of the re-entry of flue gases has been
traced the device can be put back into operation by
pressing its reset button. If this failure occurs frequently,
this indicates that the flue suffers from down draught
conditions. It is recommended that a competent person
carry out the necessary remedial action.
Important
The combustion products discharge safety device must
never be put out of operation. Re-entry of flue gases to
the building could be harmful and cause poisoning or
death.
1.3
Technical information
1.3.1 Dimensions
The flue pipe must at least have the same diameter as
the spigot on the water heater (dimension G).
Dimensions
DR-SA 16
DR-SA 19
A
1585
1780
B
1450
1640
D
645
675
E
770
775
G
130
130
K
340
340
M
1505
1685
N
1505
1685
R
285
285
S
1280
1460
1
Cold water inlet
2
Hot water outlet
3
Gas control valve
4
Drain valve
5
T&P valve tapping
6
Access door opening
All dimensions are given in mm. (rounded off to 5mm).
See figure 3.
Figure 3 - Dimensions
1) Cold water inlet
2) Hot water outlet
3) Gas control valve
4) Drain valve
5) T&P valve tapping
6) Access door opening