 Do not use a metal scraper to remove deposits. 

You will damage the glass lining.
After cleaning, replace the clean out door with new gasket 

if required. Refill heater and check for leaks.

Note:

 The maintenance of the waterside of the system 

may require additional cleaning and disinfecting before 
being placed into service. Refer to BS 6700.

2.7.4   Spare parts

To be able to order spare parts it is important to note the 
model number of the heater as well as the serial number. 
Based on this information the detailed spare parts can be 
determined.

2.8   Condensation

If the appliance is filled with cold water or if the hot 

water consumption is very high, condensation of flue 

gases will occur on the cold surfaces of the combustion 

chamber and the flue tube. The water droplets will fall on 

the burner and cause a sizzling noise. This is a normal 
phenomenon that will disappear as soon as the heater 
reaches its normal operating temperature.

2.9   Important warning

The heater must never be placed into operation with a 
closed cold water supply! Provision must always be made 
for expansion.

3.  

FOR THE USER

3.1   Instructions for use

Note:

 Refer to the data label to confirm for which gas the 

heater is adjusted.

Warning: 

All installations 

MUST 

conform to the 

relevant Gas Safety and Building Regulations. It is law 
that competent persons in accordance with the above 
regulations install all gas appliances.

The electrical supply to the heater 

MUST

 be switched 

OFF 

before attempting service or maintenance.

This appliance 

MUST 

be suitably earthed.

Filling the water heater

1.   Close the drain valve.
2.   Open the cold water valve to the water heater and 

open all hot water taps. The water heater is filled as 

soon as cold water flows from all taps.

3.   Close all hot water taps.

Lighting instructions

1.  Check that the heater is full of water by ensuring water 

flows at constant pressure from a hot tap connected to 

the heater system.

2.  Switch the mains electricity supply to the heater 

OFF.

3.  Turn the heater thermostat to the lowest setting.

4.  Press the safety thermostat reset button firmly to 

make sure it is reset.

5.  Press the combustion products discharge safety 

device reset button firmly to make sure it is reset.

6.  Make sure the manual gas shut off valve is open.
7.  Switch the mains electricity supply to the heater 

ON

Set the on/off switch on the heater to 

ON

 (1) and 

adjust the control thermostat to the desired setting.

8.  If the ignition controller rest button is illuminated, wait 

30 seconds before pressing the reset button.

9.  The heater will now light if heat is required.

If the safety thermostat or the combustion-products 
discharge safety-device operates and shuts down the 

heater, find the cause of the fault before you press 

the reset button. If in doubt, contact your installer or 
Hamworthy Heating Ltd. for advice.

Operation

The gas control valve automatically regulates the gas 
supply. The main burner will ignite as soon as the 
thermostat senses a reduction in water temperature. 
The main burner will shut down as soon as the preset 
temperature is achieved. At high water temperatures there 
is more scale build-up in the heater. It is recommended 
therefore, that the thermostat is set no higher than 60 °C 
as the accumulation of scale will be minimised.

Shutting down the heater

To shut the heater off for short periods (i.e. 2 – 3 days), 
turn the heater control thermostat to minimum. Wait 2 to 3 
minutes and switch the on/off switch to 

OFF

. To switch the 

heater off for longer periods, repeat the above and turn 
both the local electrical isolator and the manual gas shut 
off valve to 

OFF

. Depending on the weather conditions 

likely to prevail during the shutdown period, consideration 
must also be given to completely draining the heater.
The manual gas shut off valve must not be used except 
in emergencies, for long periods of shutdown or during 
servicing.

Additional safety advice

1.  Do not block or obstruct ventilation grilles.
2.  If at any time a gas leak is suspected, turn 

OFF

 gas 

supply – 

DO NOT use a naked flame – DO NOT use 

electrical switches, alarms or lights – DO open 

windows

 – contact your nearest Gas Conveyor office 

immediately. Generally their telephone number can be 
located under 

GAS 

in your telephone directory.

3.  If you consider the heater to be malfunctioning, turn it 

OFF

 and seek expert advice.

4.  To make sure safe and efficient operation at all times, 

it is essential that the heater be serviced regularly. 
Contact your installer or Hamworthy Heating Ltd for 
advice.

Содержание DR-SA 16

Страница 1: ...OCUMENT IS FOUND RELATING TO SPECIFIC GAS TO BE FIRED BEFORE FIRING HEATER THIS WATER HEATER COMPLIES WITH ALL RELEVANT EUROPEAN DIRECTIVES PUBLICATION NO 500001135 ISSUE F APRIL 2012 Dorchester DR SA...

Страница 2: ...2...

Страница 3: ...ulation system 10 2 1 3 Gas connection 12 2 1 4 Draught diverter 12 2 1 5 Flue system 12 2 1 6 Electrical connection 12 2 2 Commissioning 12 2 3 Removing and replacing the control panel front cover 13...

Страница 4: ...All Dorchester heaters are factory assembled and delivered individually packed and shrouded in polythene on a wooden pallet Within the packaging wrapped separately is the draught diverter complete wit...

Страница 5: ...rol panel 8 Inspection cover plate 9 Intermittent pilot burner and flame probe 10 Cold water inlet c w inlet tube 11 Combustion products discharge safety device 12 T P valve connection 13 Outer casing...

Страница 6: ...safety thermostat is pre set to 90 C The control panel is also fitted with an ON OFF switch I 0 At setting I the gas control is activated on the basis of heat demand from the control thermostat At set...

Страница 7: ...ons It is recommended that a competent person carry out the necessary remedial action Important The combustion products discharge safety device must never be put out of operation Re entry of flue gase...

Страница 8: ...fice G30 mm 0 23 0 23 Heating time T 45 K min 43 55 DATA G31 37 mbar Nominal output kW 17 6 19 1 Nominal load gross kW 22 5 24 5 Supply pressure G31 mbar 37 37 Gas consumption G31 kg h 1 6 1 8 Diamete...

Страница 9: ...ordance with the above regulations install all gas appliances Failure to install appliances correctly could lead to prosecution It is in your own interest and that of safety to make sure that this law...

Страница 10: ...hardness 10 0 fH English hardness 7 0 eH 100 mg l CaCO3 Conductivity 125 S cm Acidity pH value 7 0 pH value 9 5 Note If the water specifications deviate from those stated in the table then the tank p...

Страница 11: ...A Gas supply B Hot water delivery C Cold water inlet D Hot water taps E Return circulation Figure 6 Connection diagram un vented systems Un vented system see figure 6 To install a Dorchester water hea...

Страница 12: ...arapets etc If an existing chimney or flue is to be used this must be swept clean and be free of debris before an approved liner is installed and connected to the water heater Electrical supply Freque...

Страница 13: ...n set to the correct value at the factory but it must be checked again at commissioning and during the once a year and every year maintenance by adopting the following procedure 1 Shut down the heater...

Страница 14: ...ode Note On no account remove the magnesium anode without checking to make sure that the heater is fully isolated and the pressure removed 1 Close the stop valve in the cold water supply pipe 2 Open t...

Страница 15: ...discharge safety device reset button firmly to make sure it is reset 6 Make sure the manual gas shut off valve is open 7 Switch the mains electricity supply to the heater ON Set the on off switch on t...

Страница 16: ...ducts discharge Investigate the cause blocked flue incorrect safety device has operated flue wind conditions incorrect ventilation and rectify before pressing reset button on the flue thermostat Insuf...

Страница 17: ...urner D Spark electrode E Flame probe G Combustion products discharge safety device H Control thermostat K Safety thermostat M Reset button N Terminal block P Terminal block R Earth terminals S Connec...

Страница 18: ...0308 236 R3...