Water connections, Vented
Instruction Manual DR-FC
25
is
3.7
Water connections,
Vented
3.7.1
Cold water side
See
1. Fit an approved stop valve
on the cold water side between the water
and the water heater, as required by regulations. Refer also to
’1.3 Regulations and documents’
3.7.2
Top to bottom recirculating pump
You can connect a top to bottom recirculation pump to prevent stratification of
the water ("stacking")in the water heater.
1. Fit a pipe (Ø 22 mm), a stop valve
and a top to bottom recirculation
pump
2. Fit non-return valve
.
3. Fit stop valves
.
3.7.3
Hot water side
See
n
Remark
Insulating long hot water pipes prevents unnecessary energy loss.
1. Fit the safety valve
2. Optional: fit a temperature gauge
to be able to check the temperature of
the tap water.
3. Fit a stop valve
in the hot water outlet pipe, for use when servicing.
4. If a circulation pipe is to be fitted, then refer to paragraph
3.7.4
Circulation pipe
See
If an immediate flow of hot water is required at draw-off points, a circulation
pump can be installed. This improves comfort and reduces water wastage.
1. Fit a circulation pump
of the correct capacity for the length and resistance
of the circulation system.
2. Fit a non-return valve
a downstream the circulation pump to guarantee the
direction of circulation.
3. Fit two stop valves
for service purposes.
4. Connect the circulation pipe to the cold water supply pipe.
3.7.5
Condensation drainage
See paragraph
3.8
Gas connection
Warning
Gas installation may only be carried out by an authorised installer in
compliance with the general regulations imposed by the gas company.
Refer also to paragraph
’1.3 Regulations and documents’
c
Note
Make sure that the diameter and length of the gas supply pipe are large
enough to supply sufficient capacity to the water heater.
Содержание DR-FC 25
Страница 2: ...2...
Страница 6: ...6 Instruction Manual DR FC gis A Appendices 95 A 1 Introduction 95 A 2 Electrical diagram DR FC 96...
Страница 16: ...Functioning of the water heater 16 Instruction Manual DR FC 2 gis...
Страница 42: ...Filling and draining 42 Instruction Manual DR FC 4 gis...
Страница 46: ...The control panel 46 Instruction Manual DR FC 5 gis...
Страница 50: ...Status of the water heater 50 Instruction Manual DR FC 6 gis...
Страница 56: ...Starting up and shutting down 56 Instruction Manual DR FC 7 gis...
Страница 68: ...Main menu 68 Instruction Manual DR FC 8 gis...
Страница 72: ...Service program 72 Instruction Manual DR FC 9 is...
Страница 88: ...Troubleshooting 88 Instruction Manual DR FC 10 gis...
Страница 90: ...Maintenance frequency 90 Instruction Manual DR FC 11 gs...
Страница 98: ...Appendices 98 Instruction Manual DR FC A is...